[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929202":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},929202,600,1,"单选题","按下列条件确定。图为某办公楼底层局部承重横墙的示意图。墙体厚240mm，横墙间距6m，采用Mu10普通砖、M5混合砂浆砌筑。 试验算外纵墙上截面为b×h=240mm×400mm的钢筋混凝土挑梁下砖砌体的局部受压承载力（kN），并指出其值与下列何项数值最为接近？（ ）",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","132.7",false,{"key":16,"text":17,"correct":14},"B","159.3",{"key":19,"text":20,"correct":14},"C","166.9",{"key":22,"text":23,"correct":24},"D","191.1",true,"根据《砌体结构设计规范》（GB 50003—2011）第5.2.4条规定，已知局部受压面积为：Al=1.2bh=1.2×240×400=115200mm2；砌体局部抗压强度提高系数为：γ=1.5；梁端底面压应力图形的完整系数为：η=0.7；又f=1.58，则局部受压承载力为： ηγfAl=0.7×1.5×1.58×115200=191117N=191.1kN。由此可知，D项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]