[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929165":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},929165,600,1,"单选题","已知柱间基础上的承重墙体高15m，双面抹灰、墙厚240mm，采用Mu10烧结普通砖，M5混合砂浆砌筑，墙上门洞尺寸如图4-22所示，柱间距6m，基础梁长5.45m，基础梁断面尺寸为b×hb=240mm×450mm，伸入支座0.3m；混凝土为C30，纵筋为HRB335，箍筋为HPB235。 施工阶段托梁的弯矩及剪力设计值承载力为（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","46kN·m；34kN",true,{"key":16,"text":17,"correct":18},"B","54kN·m；72kN",false,{"key":20,"text":21,"correct":18},"C","65kN·m；46kN",{"key":23,"text":24,"correct":18},"D","72kN·m；112kN","由题意可知，托梁自重为：3.24kN\u002Fm； 墙体自重为：1.2×19×0.24×（2.4×5.15-1×2.4）\u002F5.15=10.58kN\u002Fm； 根据《砌体结构设计规范》（GB 50003—2011）第7.3.4条第1款规定，作用在托梁上的均布荷载为：3.24+10.58=13.82kN\u002Fm； 则施工阶段托梁的弯矩设计值为：M=13.82×5.152\u002F8=45.83kN·m，剪力设计值为：V=13.82×4.85\u002F2=33.52kN。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]