[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929112":3},{"question":4,"library":24},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":13},929112,600,1,"单选题","非抗震设防区某四层教学楼局部平面如图所示。各层平面布置相同，各层层高均为3.6m。楼、屋盖均为现浇钢筋混凝土板，静力计算方案为刚性方案。墙体为网状配筋砖砌体，采用MU10级烧结普通砖，M10级水泥砂浆砌筑，钢筋网采用乙级冷拔低碳钢丝 方格钢筋网间距为40mm，网的竖向间距130mm。纵横墙厚度均为240mm，砌体施工质量控制等级为B级。第二层窗间墙A的轴向力偏心距e=24mm。[2012年真题]",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","",false,{"key":16,"text":17,"correct":14},"B","2.假定，墙体体积配筋百分率ρ=0.6。试问，第二层窗间墙A的受压承载力设计值（kN）与下列何项数值最为接近？（ ）",{"key":19,"text":20,"correct":21},"C","提示：窗间墙A的承载力影响系数为ψn。",true,{"key":23,"text":13,"correct":14},"D",{"id":6,"name":25,"category":26,"favorite":27},"(结构) 专业考试一级","建筑工程",0]