[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929082":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},929082,600,1,"单选题","某多层砌体结构承重墙段 A，如图所示，两端均设构造柱，墙厚240mm，长度4000mm，采用烧结普通砖砌筑。 2.在墙段正中部位增设一构造柱，如图4-37所示，构造柱混凝土强度等级为C20，每根构造柱均配4φ14纵向钢筋（As=615mm2）。试问，该墙段的最大截面受剪承载力设计值（kN）应与下列（ ）项数值最为接近。 提示：ft=1.1N\u002Fmm2，fy=270N\u002Fmm2，γRE=0.85，取fVE=0.2N\u002Fmm2进行计算。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","240",false,{"key":16,"text":17,"correct":14},"B","265",{"key":19,"text":20,"correct":21},"C","285",true,{"key":23,"text":24,"correct":14},"D","315","根据《建筑抗震设计规范》（GB 50011—2010）第7.2.7条式（7.2.7-3）计算， A=240×4000=960000mm2；中部构造柱的横截面总面积为：Ac=240×240=57600mm2；Ac\u002FA=57600\u002F960000=0.06＜0.15；ζc=0.5，γRE=0.85； 构造柱间距＜3.0m，取ηc=1.1；则该墙段的最大截面受剪承载力设计值为： 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]