[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929078":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},929078,600,1,"单选题","某房屋轴心受压基础短柱墩，截面尺寸为490mm×490mm，采用MU15烧结多孔砖（孔洞率为28%）和M10水泥砂浆砌筑，其轴压承载力（kN）与下列（ ）项数值接近。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","469",false,{"key":16,"text":17,"correct":14},"B","499",{"key":19,"text":20,"correct":21},"C","521",true,{"key":23,"text":24,"correct":14},"D","555","根据《砌体结构设计规范》（GB 50003—2011）第3.2.1条表3.2.1-1可知，抗压强度设计值f=2.31MPa；根据第3.2.3条第1款规定，A=0.492=0.24m2＜0.3m2，则砌体强度调整系数为：γa2=0.7＋A=0.7＋0.24=0.94，故砌抗压强度设计值f=0.94×2.31=2.1714MPa；对轴压短柱φ=1.0，根据式（5.1.1）计算，该柱的轴压承载力为：N=φAf=4902×2.17=521.53kN。由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]