[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-929042":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},929042,600,1,"单选题","某三层无筋砌体房屋（无吊车），现浇钢筋混凝土楼（屋）盖，刚性方案，墙体采用MU15级蒸压灰砂砖，M7.5级水泥砂浆砌筑，施工质量控制等级为B级，安全等级二级。各层砖柱截面均为370mm×490mm，基础埋置较深且底层地面设置刚性地坪，房屋局部剖面示意如图所示。 2.若取ψ=0.9，试问，二层砖柱的轴心受压承载力设计值（kN），应与下列哪项数值最为接近？（ ）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","295",true,{"key":16,"text":17,"correct":18},"B","245",false,{"key":20,"text":21,"correct":18},"C","215",{"key":23,"text":24,"correct":18},"D","185","由于墙体采用MU15级蒸压灰砂砖，M7.5级水泥砂浆砌筑，根据《砌体结构设计规范》（GB 50003—2011）第3.2.1条表3.2.1-3可知，f＝2.07MPa； 因A＝0.37×0.49＝0.1813mm2＜0.3m2，根据第3.2.3条第1款规定，截面塑性发展系数为：＝0.1813+0.7=0.8813； 根据第5.1.1条式（5.1.1）计算，二层砖柱的轴心受压承载力设计值为：Nu=ψfA＝0.9×0.8813×2.07×370×490＝297.67kN。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]