[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928999":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928999,600,1,"单选题","一钢筋混凝土柱截面尺寸为250mm×250mm，支承在370mm宽的条形砖基础上，作用位置如图所示。砖基础用MU10烧结普通砖和M5水泥砂浆砌筑，柱传至基础上的荷载设计值为150kN。要求确定柱下基础砌体的局部受压承载力关系式中右端项γfAl最接近于（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","165.9",true,{"key":16,"text":17,"correct":18},"B","149.3",false,{"key":20,"text":21,"correct":18},"C","140.6",{"key":23,"text":24,"correct":18},"D","125.0","根据《砌体结构设计规范》（GB 50003—2011）第5.2.2~5.2.3条计算如下： 局部受压面积为：Al=250×250=62500mm2； 局部受压计算面积为：A0=（b+2h）h=（250+2×370）×370=366300mm2； 局部受压强度提高系数为： 砖基础用MU10烧结普通砖和M5水泥砂浆砌筑，根据第3.2.1条表3.2.1-1可知，砌体抗压强度设计值为：f=1.5MPa； 则砌体局部受压承载力为：γfAl=1.77×1.5×62500×10-3=165.9kN。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]