[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928788":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},928788,600,1,"单选题","关于考虑地震作用组合的预埋件设计，下列叙述不正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","预埋件锚筋截面计算的承载力抗震调整系数应取&gamma;RE＝1.0",false,{"key":16,"text":17,"correct":18},"B","直锚钢筋实配的锚筋截面面积可按《混凝土结构设计规范》（GB50010&mdash;2010）第9章有关规定计算",true,{"key":20,"text":21,"correct":14},"C","直锚钢筋的锚固长度，应按《混凝土结构设计规范》（GB50010&mdash;2010）第9章的有关规定采用",{"key":23,"text":24,"correct":14},"D","铰接排架柱柱顶埋件直锚筋应符合下列要求：当为一级抗震等级时，取4根直径16mm的直锚筋；当为二级抗震等级时，取4根直径为14mm的直锚筋","根据《混凝土结构设计规范》（GB 50010&mdash;2010）第11.1.9条第1条规定，考虑地震作用的预埋件，直锚钢筋截面面积可按本规范第9章的有关规定计算并增大25%，且应适当增大锚板厚度。A项，根据表11.1.6注规定，预埋件锚筋截面计算的承载力抗震调整系数&gamma;RE应取为1.0；C项，根据第11.1.9条第2款规定，锚筋的锚固长度应按本规范第9.7节的有关规定并增加10%；D项，对于铰接排架柱柱顶预埋件直锚筋的相关规定为：①当为一级抗震等级时，取4根直径16mm的直锚筋；②当为二级抗震等级时，取4根直径14mm的直锚筋。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]