[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928759":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928759,600,1,"单选题","如图2-26所示某钢筋混凝土连续梁梁端支承180mm厚砖墙上，梁截面为250×500mm2，混凝土为C30级，纵筋为HRB335级。经计算梁端处的组合内力设计值为M＝0，V＝150kN，梁跨中需配置318的受力纵筋。试问钢筋伸入支座的锚固长度l1、l2应采用下列（ ）组数值。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","l1＝150mm；l2＝70mm",true,{"key":16,"text":17,"correct":18},"B","l1＝150mm；l2＝0mm",false,{"key":20,"text":21,"correct":18},"C","l1＝120mm；l2＝60mm",{"key":23,"text":24,"correct":18},"D","l1＝100mm；l2＝100mm","C30级混凝土轴心抗拉强度设计值ft＝1.43N\u002Fmm2；混凝土保护层厚度c取35mm，梁截面有效高度h0＝500-35＝465mm；M＝0端为简支端。根据《混凝土结构设计规范》（GB 50010—2010）第9.2.2条第1款规定，V＝150kN＞0.7ftbh0＝0.7×1.43×250×465＝116.4kN，HRB335级钢筋为带肋钢筋，则从支座边缘算起的钢筋锚固长度应满足：las≥12d＝12×18＝216mm。l1＝150mm，l2＝70mm即可满足规范要求。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]