[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928741":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928741,600,1,"单选题","某规则框架—剪力墙结构，框架的抗震等级为二级。梁、柱混凝土强度等级均为C35。某中间层的中柱净高Hn=4m，柱除节点外无水平荷载作用，柱截面b×h=1100mm×1100mm，as=50mm，柱内箍筋采用井字复合箍，箍筋采用HRB500钢筋，其考虑地震作用组合的弯矩如图2-5所示。假定，柱底考虑地震作用组合的轴压力设计值为13130kN。试问，按《建筑抗震设计规范》GB 50011—2010的规定，该柱箍筋加密区的最小体积配箍率与下列何项数值最为接近？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","0.5％",false,{"key":16,"text":17,"correct":14},"B","0.6％",{"key":19,"text":20,"correct":21},"C","1.2％",true,{"key":23,"text":24,"correct":14},"D","1.5％","",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]