[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928698":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},928698,600,1,"单选题","某7层住宅，层高均为3.1m，房屋高度22.3m，安全等级为二级，采用现浇钢筋混凝土剪力墙结构，混凝土强度等级为C35，抗震等级三级，结构平面立面均规则。某矩形截面墙肢尺寸bw×hw=250mm×2300mm，各层截面保持不变。 假定，该墙肢底层底截面的轴压比为0.58，三层底截面的轴压比为0.38。试问，下列对三层该墙肢两端边缘构件的描述何项是正确的？（ ）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","需设置构造边缘构件，暗柱长度不应小于300mm",false,{"key":16,"text":17,"correct":18},"B","需设置构造边缘构件，暗柱长度不应小于400mm",true,{"key":20,"text":21,"correct":14},"C","需设置约束边缘构件，lc不应小于500mm",{"key":23,"text":24,"correct":14},"D","需设置约束边缘构件，lc不应小于400mm","根据《建筑抗震设计规范》（GB 50011—2010）第6.1.10条第2款可知，房屋高度22.3m小于24m，底部加强部位可取底部一层；根据第6.4.5条第2款可知，该墙肢底层底截面的轴压比为0.58大于该规范表6.4.5-1的规定，三层可设置构造边缘构件；根据图6.4.5-1a可知，暗柱长度不小于max（bw，400）=400mm。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]