[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928662":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},928662,600,1,"单选题","钢筋混凝土T形截面构件如图所示，b＝250mm，h＝500mm，b f′＝400mm，hf′＝150mm，混凝土强度等级为C30，纵筋采用HRB335钢筋，箍筋采用HPB300钢筋。受扭纵筋与箍筋的配筋强度比值为ζ＝1.2，Acor＝90000mm2。 3.设构件承受剪力设计值V＝80kN，箍筋间距s＝100mm，受扭纵筋与箍筋的配筋强度比值为ζ＝1.2，腹板的塑性抵抗矩Wtw和所受扭矩Tw的比值为0.98，已知构件须按剪扭构件计算，则腹板的抗剪箍筋的计算面积Asv最接近于（ ）mm2。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","50",false,{"key":16,"text":17,"correct":14},"B","29",{"key":19,"text":20,"correct":14},"C","25",{"key":22,"text":23,"correct":24},"D","14",true,"对于腹板，考虑其承受扭矩和全部剪力，按剪扭构件考虑，根据《混凝土结构设计规范》（GB 50010—2010）第6.4.8条式（6.4.8-2）计算，剪扭构件混凝土受扭承载力降低系数βt为： 则取βt＝1.0。 根据第6.4.8条公式（6.4.8-2）计算，剪扭构件的受剪承载力为： V≤（1.5-βt）0.7ftbh0+1.25fyvAsvh0\u002Fs； 故抗剪箍筋面积为： ＝[80000－（1.5－1.0）×0.7×1.43×250×465]×100\u002F1.25\u002F270\u002F465 ＝14mm2。 由此可知，D项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]