[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928650":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928650,600,1,"单选题","板柱结构，柱网尺寸8.1m×8.1m，板厚200mm，中柱截面尺寸为b×h=700mm×700mm，采用C30混凝土，受冲切钢筋用HPB300级，若板上作用的荷载设计值g＋q=11.8kN\u002Fmm2，则仅采用箍筋作为受冲切钢筋所需的箍筋面积Asuv最接近于（ ）mm2。 提示：as=20mm，γ0=1.0。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1432.1",true,{"key":16,"text":17,"correct":18},"B","1520.3",false,{"key":20,"text":21,"correct":18},"C","1641.8",{"key":23,"text":24,"correct":18},"D","1720.7","h0=h-as=180mm，集中反力设计值为：Fl=11.8×8.12-11.8×（0.7＋2×0.18）2=760.94kN，fyv=270N\u002Fmm2，ft=1.43N\u002Fmm2； 根据《混凝土结构设计规范》（GB 50010—2010）第6.5.1条规定，对于中柱，αz=40，临界截面周长为：um=（700＋180\u002F2×2）×4=3520mm； 取η= 又根据第6.5.3条式（6.5.3-2）计算，并且不考虑预应力的情况下箍筋面积为： 由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]