[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928625":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928625,600,1,"单选题","某承受均布荷载的简支梁跨度l0＝5m，截面尺寸b×h＝200mm×500mm，混凝土强度等级为C20，箍筋为HPB300级，纵筋为HRB335级钢筋，单排纵向受力钢筋，梁净跨为5m，as＝40mm。假设梁的支座截面承受剪力设计值V＝150kN，则该截面所需的箍筋总面积与间距的比值Asv\u002Fs最接近于（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","0.51",false,{"key":16,"text":17,"correct":14},"B","0.54",{"key":19,"text":20,"correct":21},"C","0.65",true,{"key":23,"text":24,"correct":14},"D","0.82","根据《混凝土结构设计规范》（GB 50010—2010）第6.3.4条式（6.3.4-1）计算，0.7ftbh0＝0.7×1.10×200×460＝70840N＜V＝150000N，需要按计算确定腹筋；当V＞0.7ftbh0、300＜H≤500mm，构造要求为：最小配箍面积：Asv，min＝（0.24ft\u002Ffyv）×b×s＝（0.24×1.10\u002F270）×200×200＝39.1mm2；箍筋最小直径Dmin＝6mm，箍筋最大间距smax＝200mm；复核截面尺寸为：hw＝h0＝460mm；根据第6.3.1条规定，矩形截面受弯构件，其受剪截面应符合下式条件：当hw\u002Fb≤4时，V≤0.25βc×fc×b×h0，即0.25βc×fc×b×h0＝0.25×1.00×9.55×200×460＝219650N≥V＝105336N，满足要求；根据第6.3.4条规定，矩形截面的一般受弯构件，其斜截面受剪承载力按下列公式计算：；代入数据解得，该截面所需的箍筋总面积与间距的比值为： 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]