[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928614":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928614,600,1,"单选题","某钢筋混凝土梁，同时承受弯矩、剪力和扭矩的作用，不考虑抗震设计。梁截面为400mm×500mm，混凝土强度等级C30，梁内配置四肢箍筋，箍筋采用HPB300级钢筋。经计算，Astl\u002Fs=0.65mm，Asv\u002Fs=2.15mm，其中，Astl为受扭计算中沿截面周边配置的箍筋单肢截面面积，Asv为受剪承载力所需的箍筋截面面积，s为沿构件长度方向的箍筋间距。试问，至少选用下列何项箍筋配置才能满足计算要求？（ ）[2011年真题]",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","Φ8@100",false,{"key":16,"text":17,"correct":14},"B","Φ10@100",{"key":19,"text":20,"correct":21},"C","Φ12@100",true,{"key":23,"text":24,"correct":14},"D","Φ14@100","受剪扭所需的总箍筋面积为：2Astl+Asv。如果配置的箍筋肢数较多，剪扭构件中还应满足沿截面周边配置的箍筋单肢截面面积不小于Astl。根据题中所给选项信息，按照四肢箍、箍筋间距为100mm进行计算： ①抗扭和抗剪所需的总箍筋面积为：Asv，t=（0.65×100×2+2.15×100）mm2=345mm2； ②单肢箍筋面积为：Asv，tl=345\u002F4mm2=86.25mm2； ③外圈单肢抗扭箍筋截面为：Astl=0.65×100mm2=65mm2；max（Asv，tl，Astl）=86.25mm2； 因此，单肢箍筋面积至少应取86.25mm2。经比较，选用Φ12，Asvl=113mm2。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]