[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928590":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928590,600,1,"单选题","某三跨十层现浇框架，抗震等级二级，第一层层高3.9m，地面到基础顶面1.1m，柱截面尺寸为500mm×500mm，梁高600mm，混凝土C25，纵筋HRB335级，箍筋HPB300级，在竖向荷载地震作用组合下内柱有关截面如图所示，其内力值见表。 2.柱顶Ⅱ—Ⅱ截面处对称配筋As＝As′＝（ ）mm2。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","636",true,{"key":16,"text":17,"correct":18},"B","787",false,{"key":20,"text":21,"correct":18},"C","927",{"key":23,"text":24,"correct":18},"D","1057","题（1）已求得构件界限受压承载力设计值Nb＝1882kN，因左震、右震时的轴压力均小于Nb，故按大偏心受压计算。N左 M右，左震为最不利工况，取N=1300kN，M=270kN·m进行配筋计算； 根据已知条件得底层柱上端节点处的弯矩作用情况，如图所示。 . 则考虑地震作用组合的节点上、下柱端的弯矩设计值之和为：∑Mc=270+270=540kN·m，1.2∑Mb=1.2×（160+317）=572kN·m； ∑Mc 轴向力对截面重心的偏心距为： 附加偏心距为：ea＝20mm，则可得初始偏心距为：ei＝e0+ea＝220+20＝240mm； 根据《混凝土结构设计规范》（GB 50010—2010）式（6.2.17-3）计算，轴向力作用点至受拉钢筋合力点之间的距离为： 将x＝175mm，e＝501mm，代入式 可得： 解得柱顶Ⅱ—Ⅱ截面处对称配筋截面面积为：As＝As′＝636mm2。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]