[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928589":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},928589,600,1,"单选题","某三跨十层现浇框架，抗震等级二级，第一层层高3.9m，地面到基础顶面1.1m，柱截面尺寸为500mm×500mm，梁高600mm，混凝土C25，纵筋HRB335级，箍筋HPB300级，在竖向荷载地震作用组合下内柱有关截面如图所示，其内力值见表。 3.柱斜截面抗剪配筋Asv\u002Fs为（ ）mm2\u002Fmm。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","0.465",false,{"key":16,"text":17,"correct":14},"B","0.515",{"key":19,"text":20,"correct":14},"C","0.565",{"key":22,"text":23,"correct":24},"D","0.651",true,"根据《混凝土结构设计规范》（GB 50010—2010）第11.4.3条式（11.4.3-3）计算，剪力设计值为： 计算剪跨比λ=Hn\u002F2\u002Fh0=4.4\u002F2\u002F0.46=4.78>2； 根据第11.4.6条式（11.4.6-1）计算，受剪截面应满足： 承载力抗震调整系数γRE＝0.85，混凝土强度影响系数βc＝1.0，即可得： =（1\u002F0.85）×（0.2×1.0×11.9×500×460）=644×103N=644kN>V=207.5kN（满足要求） 斜截面抗震受剪承载力应满足： 求得轴向压力设计值为：0.3fcA=0.3×11.9×5002=892.5×103N 3，取λ＝3； 代入上述公式可得： 解得，柱斜截面抗剪配筋Asv\u002Fs为：Asv\u002Fs=0.651mm2\u002Fmm。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]