[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928583":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928583,600,1,"单选题","某无梁楼盖柱网尺寸为6m×6m，柱截面尺寸为450mm×450mm，楼板厚200mm，如图所示，混凝土强度等级为C25，箍筋采用HPB300钢筋，弯起钢筋采用HRB335钢，as＝20mm。如图所示。 {图} 4.集中反力设计值大小同题（3），采用弯起钢筋作为受冲切钢筋时，冲切破坏锥体每一侧所需的弯起钢筋面积与（ ）配置最为接近（弯起角度为α＝45°）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","3φ12",true,{"key":16,"text":17,"correct":18},"B","2φ12",false,{"key":20,"text":21,"correct":18},"C","3φ16",{"key":23,"text":24,"correct":18},"D","34φ14","各参数取值同上题：um＝4×（450＋180）＝2520mm；η＝1.0。 根据《混凝土结构设计规范》（GB50010-2010）第6.5.3条式（6.5.3-2）计算，弯起钢筋总面积为： 冲切破坏锥体每一侧的弯起钢筋面积为Asbu\u002F4＝802\u002F4＝200mm2，根据第9.1.11条第3款规定，每一侧采用3φ12，As＝339mm2>200，满足规范要求。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]