[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928581":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928581,600,1,"单选题","某五层中学教学楼，采用现浇钢筋混凝土框架结构，框架最大跨度9m，层高均为3.6m，抗震设防烈度7度，设计基本地震加速度0.10g，建筑场地类别Ⅱ类，设计地震分组第一组，框架混凝土强度等级C30。[2014年真题] 假定，采用振型分解反应谱法进行多遇地震作用计算，相邻振型的周期比小于0.85，顶层框架柱的反弯点位于层高中点，当不考虑偶然偏心的影响时，水平地震作用效应计算取前3个振型，某顶层柱相应于第一、第二、第三振型的层间剪力标准值分别为300kN、-150kN、50kN。试问，地震作用下该顶层柱柱顶弯矩标准值Mk（kN·m），与下列何项数值最为接近？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","360",false,{"key":16,"text":17,"correct":14},"B","476",{"key":19,"text":20,"correct":21},"C","610",true,{"key":23,"text":24,"correct":14},"D","900","水平地震作用下弯矩标准值为：M1k=300×3.6／2=540kN·m；M2k=-150×3.6／2=-270kN·m；M3k=50×3.6／2=90kN·m，根据《建筑抗震设计规范》（GB 50011—2010）第5.2.2条式（5.2.2-3）计算，当相邻振型的周期比小于0.85时，该顶层柱柱顶弯矩标准值为： 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]