[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928574":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},928574,600,1,"单选题","牛腿尺寸如图2-3所示，结构安全等级为二级，柱截面宽度b=400mm，高度h=600mm，as=40mm，作用于牛腿顶部的竖向力设计值Fv=450kN，水平拉力设计值Fh=90kN，混凝土强度等级为C30，牛腿纵向受力钢筋采用HRB400，箍筋采用HPB300。试问，牛腿的配筋面积As（mm2）与下列何项数值最为接近？（ ）[2014年真题]",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","450",false,{"key":16,"text":17,"correct":14},"B","480",{"key":19,"text":20,"correct":14},"C","750",{"key":22,"text":23,"correct":24},"D","780",true,"根据《混凝土结构设计规范》（GB 50010—2010）第9.3.11条式（9.3.11）计算，a=max（0.3h0，150+20）=max（0.3×560，170）=170mm。 根据第9.3.12条规定，承受竖向力所需的纵向受力钢筋的配筋率不应小于0.2％及0.45ft\u002Ffy，即 取ρmin=0.2％。承受竖向力的纵向受拉钢筋截面面积：Asv,min=ρminbh=0.002×400×600=480mm2。所以As=480+300=780mm2。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]