[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928566":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928566,600,1,"单选题","一无吊车工业厂房，采用刚性屋盖，跨度为15m，其铰接排架结构计算简图及所承受的荷载设计值如图所示。柱的截面尺寸为400mm×400mm，as＝40mm，混凝土强度等级为C30，结构安全等级为二级，纵向受力钢筋为HRB335。 3.假定柱的轴向压力设计值N＝680kN，柱的初始偏心距ei＝314mm，偏心距增大系数η＝1.18。试问如按对称配筋进行设计，则受压区纵筋的计算面积As′最接近于（ ）mm2。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1230",true,{"key":16,"text":17,"correct":18},"B","1389",false,{"key":20,"text":21,"correct":18},"C","1543",{"key":23,"text":24,"correct":18},"D","1792","根据《混凝土结构设计规范》（GB 50010—2010）第6.2.17条式（6.2.17-3）计算，轴向压力作用点至纵向受拉钢筋的合力点的距离为： 根据第6.2.17条式（6.2.17-1）计算，正截面受压承载力应满足：N≤α1fcbx＋fy′As′－σsAs，当采用对称配筋时，可令fy′×As′＝σs×As，则可计算得受压区高度为： 故属于大偏心受压构件； 当x≥2as′时，根据第6.2.17条式（6.2.17-2）计算， 可得受压区纵筋面积为： 由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试一级","建筑工程",0]