[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-599-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":605},{"id":5,"name":6,"category":7,"favorite":8},599,"(结构) 专业考试二级","建筑工程",0,2,50,724,[13,34,46,58,70,82,94,106,118,130,142,154,165,177,187,198,210,222,234,246,258,270,282,294,306,314,326,338,350,362,374,385,393,405,417,429,441,453,465,477,485,497,509,521,533,545,557,569,581,593],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},927877,1,"单选题","钢筋混凝土梁底有锚板和对称配置的直锚筋所组成的受力预埋件，如图所示。构件安全等级均为二级，混凝土强度等级为C35，直锚筋为6φ16（HRB400级），已采取防止锚板弯曲变形的措施。所承受的荷载F作用点位于锚板表面中心，力的作用方向如图所示。[2011年真题] 1.当不考虑地震作用组合时，该预埋件可以承受的最大荷载设计值Fmax（kN）与下列何项数值最为接近？（ ）提示：预埋件承载力由锚筋面积控制。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","3500",false,{"key":24,"text":25,"correct":26},"B","3900",true,{"key":28,"text":29,"correct":22},"C","4300",{"key":31,"text":32,"correct":22},"D","4700","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},927878,"钢筋混凝土梁底有锚板和对称配置的直锚筋所组成的受力预埋件，如图所示。构件安全等级均为二级，混凝土强度等级为C35，直锚筋为6φ16（HRB400级），已采取防止锚板弯曲变形的措施。所承受的荷载F作用点位于锚板表面中心，力的作用方向如图所示。[2011年真题] 2.在Fmax作用下且直锚筋未采取附加横向钢筋等措施时，图中数值a（mm）至少应取下列何项数值？（ ）",[38,40,42,44],{"key":20,"text":39,"correct":22},"50",{"key":24,"text":41,"correct":26},"70",{"key":28,"text":43,"correct":22},"100",{"key":31,"text":45,"correct":22},"120",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},927879,"某工地需使用盘条供应的钢筋，使用前采用冷拉方法调直。试问，钢筋采用HRB335级，调直时钢筋的冷拉率不宜大于下列何项数值？（ ）[2011年真题]",[50,52,54,56],{"key":20,"text":51,"correct":22},"0.5％",{"key":24,"text":53,"correct":26},"1％",{"key":28,"text":55,"correct":22},"1.5％",{"key":31,"text":57,"correct":22},"2％",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},927880,"拟在天津市河西区建造一座7层的住宅楼，房屋高度22m，平面和立面均规则，采用现浇钢筋混凝土框架—剪力墙结构，抗震设防类别为丙类，场地类别为Ⅲ类，设计使用年限为50年。为了保证户内的使用效果，其框架柱全部采用异形柱。在基本振型地震作用下，框架部分承受的地震倾覆力矩为结构总地震倾覆力矩的26％。[2011年真题] 1.试问，异形柱框架应按下列何项抗震等级采取抗震构造措施？（ ）",[62,64,66,68],{"key":20,"text":63,"correct":22},"一级",{"key":24,"text":65,"correct":26},"二级",{"key":28,"text":67,"correct":22},"三级",{"key":31,"text":69,"correct":22},"四级",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},927881,"拟在天津市河西区建造一座7层的住宅楼，房屋高度22m，平面和立面均规则，采用现浇钢筋混凝土框架—剪力墙结构，抗震设防类别为丙类，场地类别为Ⅲ类，设计使用年限为50年。为了保证户内的使用效果，其框架柱全部采用异形柱。在基本振型地震作用下，框架部分承受的地震倾覆力矩为结构总地震倾覆力矩的26％。[2011年真题] 2.试问，上述异形柱结构，除了应在结构两个主轴方向分别计算水平地震作用并进行抗震验算以外，至少还应对与主轴成多少度的方向进行补充验算？（ ）",[74,76,78,80],{"key":20,"text":75,"correct":22},"15°",{"key":24,"text":77,"correct":22},"30°",{"key":28,"text":79,"correct":26},"45°",{"key":31,"text":81,"correct":22},"60°",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},927882,"某多层住宅，采用现浇钢筋混凝土剪力墙结构，结构平面立面均规则，抗震等级为三级，以地下室顶板作为上部结构的嵌固部位。底层某双肢墙有 A、B两个墙肢。已知A墙肢截面组合的剪力计算值Vw=180kN，同时B墙肢出现了大偏心受拉。试问，A墙肢截面组合的剪力设计值V（kN），应与下列何项数值最为接近？（ ）[2011年真题]",[86,88,90,92],{"key":20,"text":87,"correct":22},"215",{"key":24,"text":89,"correct":22},"235",{"key":28,"text":91,"correct":22},"250",{"key":31,"text":93,"correct":26},"270",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},927883,"某钢筋混凝土简支梁，安全等级为二级。梁截面250mm×600mm，混凝土强度等级C30，纵向受力钢筋均采用HRB335级钢筋，箍筋采用HPB300级钢筋，梁顶及梁底均配置纵向受力钢筋， 提示：相对界限受压区高度ξb=0.55。[2011年真题] 1.已知：梁顶面配置了2Φ16受力钢筋，梁底钢筋可按需要配置。试问，如充分考虑受压钢筋的作用，此梁跨中可以承受的最大正弯矩设计值M（kN·m），应与下列何项数值最为接近？（ ）",[98,100,102,104],{"key":20,"text":99,"correct":22},"455",{"key":24,"text":101,"correct":22},"480",{"key":28,"text":103,"correct":26},"519",{"key":31,"text":105,"correct":22},"536",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},927884,"某钢筋混凝土简支梁，安全等级为二级。梁截面250mm×600mm，混凝土强度等级C30，纵向受力钢筋均采用HRB335级钢筋，箍筋采用HPB300级钢筋，梁顶及梁底均配置纵向受力钢筋， 提示：相对界限受压区高度ξb=0.55。[2011年真题] 2.已知：梁底面配置了4Φ25受力钢筋，梁顶面钢筋可按需要配置。试问，如充分考虑受压钢筋的作用，此梁跨中可以承受的最大正弯矩设计值M（kN·m），应与下列何项数值最为接近？（ ）",[110,112,114,116],{"key":20,"text":111,"correct":22},"280",{"key":24,"text":113,"correct":26},"310",{"key":28,"text":115,"correct":22},"450",{"key":31,"text":117,"correct":22},"770",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},927885,"某钢筋混凝土方形柱为偏心受拉构件，安全等级为二级，柱混凝土强度等级C30，截面尺寸为400mm×400mm。柱内纵向钢筋仅配置了4根直径相同的角筋，角筋采用HRB335级钢筋， 已知：轴向拉力设计值N=250kN，单向弯矩设计值M=31kN·m。试问，按承载能力极限状态计算（不考虑抗震），角筋的直径（mm）至少应采用下列何项数值？（ ）[2011年真题]",[122,124,126,128],{"key":20,"text":123,"correct":22},"25",{"key":24,"text":125,"correct":26},"22",{"key":28,"text":127,"correct":22},"20",{"key":31,"text":129,"correct":22},"18",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},927886,"关于框架结构竖向活荷载最不利布置的方法，下列论述不正确的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"满布荷载法：活荷载同时作用于所有梁，求出支座和跨中弯矩直接用于内力组合",{"key":24,"text":137,"correct":22},"分层组合法：以分层法为依据，对梁只考虑本层活荷载最不利布置；对柱弯矩仅考虑上、下层活荷载影响；对柱轴力，必须考虑该层以上相邻梁布置活荷载",{"key":28,"text":139,"correct":22},"最不利荷载位置法：根据框架截面指定内力的影响线确定活荷载最不利布置",{"key":31,"text":141,"correct":22},"分跨计算组合法：活荷载逐层逐跨单独布置，分别计算内力，最后组合最不利内力",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},927887,"如图所示，由预埋板和对称于力作用线配置的弯折锚筋与直锚筋共同承受剪力的预埋件，已知承受的剪力V＝225kN，直锚筋直径d＝14mm，共4根，弯折钢筋与预埋钢板板面间的夹角α＝30°，直锚筋间的距离b1和b均为100mm，弯折钢筋之间的距离b2＝100mm，构件的混凝土为C30，钢板厚t＝10mm，直锚筋与弯折锚筋均采用HRB335钢筋，钢板为Q235钢。 . 1.弯折锚筋的截面面积最接近于（ ）mm2。",[146,148,150,152],{"key":20,"text":147,"correct":22},"685",{"key":24,"text":149,"correct":22},"602",{"key":28,"text":151,"correct":26},"566",{"key":31,"text":153,"correct":22},"453",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},927888,"如图所示，由预埋板和对称于力作用线配置的弯折锚筋与直锚筋共同承受剪力的预埋件，已知承受的剪力V＝225kN，直锚筋直径d＝14mm，共4根，弯折钢筋与预埋钢板板面间的夹角α＝30°，直锚筋间的距离b1和b均为100mm，弯折钢筋之间的距离b2＝100mm，构件的混凝土为C30，钢板厚t＝10mm，直锚筋与弯折锚筋均采用HRB335钢筋，钢板为Q235钢。 . 2.若已知弯折锚筋为3Φ18的钢筋，则弯折锚筋的锚固长度la（mm）与下列（ ）项最为接近。",[158,160,162,163],{"key":20,"text":159,"correct":26},"529",{"key":24,"text":161,"correct":22},"552",{"key":28,"text":151,"correct":22},{"key":31,"text":164,"correct":22},"648",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":28,"analysis":33},927889,"非抗震设计的钢筋混凝土梁，采用C30混凝土，HRB335级钢筋。梁内配置纵向受拉钢筋4Φ22。 1.若纵向受拉钢筋采用绑扎搭接接头，接头方式如图所示，则纵向受力钢筋最小搭接长度ll（mm）与下列（ ）项数值最为接近。",[169,171,173,175],{"key":20,"text":170,"correct":22},"650",{"key":24,"text":172,"correct":22},"780",{"key":28,"text":174,"correct":26},"910",{"key":31,"text":176,"correct":22},"1050",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},927890,"非抗震设计的钢筋混凝土梁，采用C30混凝土，HRB335级钢筋。梁内配置纵向受拉钢筋4Φ22。 若纵向受拉钢筋用2Φ25+1Φ22，采用机械连接接头，则计算纵向钢筋接头百分率时采用的“同一连接区段长度”最接近于（ ）mm。",[181,182,184,185],{"key":20,"text":170,"correct":22},{"key":24,"text":183,"correct":22},"740",{"key":28,"text":117,"correct":22},{"key":31,"text":186,"correct":26},"880",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":20,"analysis":33},927891,"某简支梁计算跨度l0＝6.9m，截面尺寸b×h＝250mm×650mm，混凝土为C30，钢筋为HRB335级。该梁承受均布恒载标准值（包括梁自重）gk＝16.20kN\u002Fm及均布活载标准值qk＝8.50kN\u002Fm，活荷载准永久系数取为ψq=0.4。梁跨中下部配有纵向受拉钢筋3Φ20（As＝941mm2），梁的混凝土保护层厚度c＝25mm。 1.跨中截面在荷载效应的标准组合作用下，纵向受拉钢筋的应力σs最接近于（ ）N\u002Fmm2。",[191,193,195,196],{"key":20,"text":192,"correct":26},"232",{"key":24,"text":194,"correct":22},"293",{"key":28,"text":113,"correct":22},{"key":31,"text":197,"correct":22},"330",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},927892,"某简支梁计算跨度l0＝6.9m，截面尺寸b×h＝250mm×650mm，混凝土为C30，钢筋为HRB335级。该梁承受均布恒载标准值（包括梁自重）gk＝16.20kN\u002Fm及均布活载标准值qk＝8.50kN\u002Fm，活荷载准永久系数取为ψq=0.4。梁跨中下部配有纵向受拉钢筋3Φ20（As＝941mm2），梁的混凝土保护层厚度c＝25mm。 2.已知As＝941mm2，αE＝7.14，γ′f＝0，ftk＝2.01N\u002Fmm2，Es=2.0×105N\u002Fmm2；假定σs＝285N\u002Fmm2，则该梁的短期刚度Bs最接近于（ ）N\u002Fmm2。",[202,204,206,208],{"key":20,"text":203,"correct":26},"5.12×1013",{"key":24,"text":205,"correct":22},"5.25×1013",{"key":28,"text":207,"correct":22},"5.30×1013",{"key":31,"text":209,"correct":22},"5.60×1013",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":33},927893,"某简支梁计算跨度l0＝6.9m，截面尺寸b×h＝250mm×650mm，混凝土为C30，钢筋为HRB335级。该梁承受均布恒载标准值（包括梁自重）gk＝16.20kN\u002Fm及均布活载标准值qk＝8.50kN\u002Fm，活荷载准永久系数取为ψq=0.4。梁跨中下部配有纵向受拉钢筋3Φ20（As＝941mm2），梁的混凝土保护层厚度c＝25mm。 荷载效应标准组合的跨中最大弯矩Mk＝Mgk+Mqk＝96.41+50.59＝147kN·m，Bs＝5.5×1013N·mm2，试确定该梁跨中挠度值f最接近于（ ）mm。",[214,216,218,220],{"key":20,"text":215,"correct":26},"23.77",{"key":24,"text":217,"correct":22},"24.22",{"key":28,"text":219,"correct":22},"30.13",{"key":31,"text":221,"correct":22},"37.44",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},927894,"某简支梁计算跨度l0＝6.9m，截面尺寸b×h＝250mm×650mm，混凝土为C30，钢筋为HRB335级。该梁承受均布恒载标准值（包括梁自重）gk＝16.20kN\u002Fm及均布活载标准值qk＝8.50kN\u002Fm，活荷载准永久系数取为ψq=0.4。梁跨中下部配有纵向受拉钢筋3Φ20（As＝941mm2），梁的混凝土保护层厚度c＝25mm。 4.若ψ＝0.506，σs＝270.0N\u002Fmm2，则该梁跨中的最大裂缝宽度wmax最接近于（ ）mm。",[226,228,230,232],{"key":20,"text":227,"correct":26},"0.241",{"key":24,"text":229,"correct":22},"0.293",{"key":28,"text":231,"correct":22},"0.304",{"key":31,"text":233,"correct":22},"0.344",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},927895,"钢筋混凝土简支矩形截面梁尺寸为250mm×500mm，混凝土强度等级为C30，梁受拉区配置3Φ20的钢筋（As=942mm2），混凝土保护层c＝25mm，承受均布荷载，梁的计算跨度l0＝6m。 1.若已知按荷载效应的准永久组合计算的跨中弯矩值Mq＝100kN·m，则裂缝间纵向受拉钢筋应变不均匀系数ψ最接近于（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"0.580",{"key":24,"text":241,"correct":22},"0.635",{"key":28,"text":243,"correct":22},"0.660",{"key":31,"text":245,"correct":26},"0.771",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},927896,"钢筋混凝土简支矩形截面梁尺寸为250mm×500mm，混凝土强度等级为C30，梁受拉区配置3Φ20的钢筋（As=942mm2），混凝土保护层c＝25mm，承受均布荷载，梁的计算跨度l0＝6m。 2.若已知裂缝间纵向受拉钢筋应变不均匀系数ψ＝0.825，则该梁的短期效应刚度最接近于（ ）kN·m2。",[250,252,254,256],{"key":20,"text":251,"correct":26},"27657",{"key":24,"text":253,"correct":22},"22702",{"key":28,"text":255,"correct":22},"22610",{"key":31,"text":257,"correct":22},"23610",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":28,"analysis":33},927897,"钢筋混凝土简支矩形截面梁尺寸为250mm×500mm，混凝土强度等级为C30，梁受拉区配置3Φ20的钢筋（As=942mm2），混凝土保护层c＝25mm，承受均布荷载，梁的计算跨度l0＝6m。 若已知梁的短期效应刚度Bs＝29732.14kN·m2，按荷载效应的标准组合计算的跨中弯矩值Mk＝90kN·m，按荷载效应的准永久组合计算的跨中弯矩值Mq＝50kN·m，梁受压区配有218的钢筋，则跨中挠度最接近于（ ）mm。",[262,264,266,268],{"key":20,"text":263,"correct":22},"10.2",{"key":24,"text":265,"correct":22},"14.3",{"key":28,"text":267,"correct":26},"16.3",{"key":31,"text":269,"correct":22},"17.9",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},927898,"如图所示，某钢筋混凝土现浇肋形楼盖的次梁，跨中承受最大正弯矩设计值M＝115kN·m。混凝土强度等级为C30，纵向受拉钢筋采用热轧HRB335钢筋。楼板厚度h f′＝80mm，次梁高度h＝450mm，宽度b＝200mm，纵向受力钢筋合力点至混凝土边缘的距离a s′＝35mm。 1.若已知次梁的计算跨度l0＝6m，间距为2.4m，净距sn＝2.2m，则翼缘的计算宽度bf′最接近于（ ）mm。",[274,276,278,280],{"key":20,"text":275,"correct":22},"1800",{"key":24,"text":277,"correct":26},"2000",{"key":28,"text":279,"correct":22},"2200",{"key":31,"text":281,"correct":22},"2400",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":33},927899,"如图所示，某钢筋混凝土现浇肋形楼盖的次梁，跨中承受最大正弯矩设计值M＝115kN·m。混凝土强度等级为C30，纵向受拉钢筋采用热轧HRB335钢筋。楼板厚度h f′＝80mm，次梁高度h＝450mm，宽度b＝200mm，纵向受力钢筋合力点至混凝土边缘的距离a s′＝35mm。 2.若已知翼缘计算宽度b f′＝1800mm，则按单筋T形截面计算的次梁跨中所需受拉钢筋计算截面面积最接近于（ ）mm2。",[286,288,290,292],{"key":20,"text":287,"correct":22},"940",{"key":24,"text":289,"correct":26},"1009",{"key":28,"text":291,"correct":22},"1033",{"key":31,"text":293,"correct":22},"1124",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},927900,"在钢筋混凝土双筋梁中，大偏心受压和大偏心受拉构件的正截面承载力计算中，要求受压区高度x≥2a′，是为了（ ）。",[298,300,302,304],{"key":20,"text":299,"correct":26},"保证受压钢筋在构件破坏时能达到其抗压强度设计值",{"key":24,"text":301,"correct":22},"防止受压钢筋压屈",{"key":28,"text":303,"correct":22},"避免保护层剥落",{"key":31,"text":305,"correct":22},"保证受压钢筋在构件破坏时能达到极限抗压强度",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},927901,"钢筋混凝土简支梁，混凝土强度等级为C30。纵向受力钢筋用HRB335级，箍筋用HPB300级。梁截面为300mm×600mm，计算配筋为As＝2700.0mm2，则梁的纵向受拉钢筋配置最合适的是（ ）。",[310,311,312,313],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":26},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":31,"analysis":33},927902,"某单筋矩形截面梁b×h＝250mm×450mm，采用C20级混凝土，配置（HRB335级）纵向受力钢筋；当发生正截面破坏时，属于下列情况中的（ ）。 提示：ρmax＝0.55fc\u002Ffy，as＝40mm。",[318,320,322,324],{"key":20,"text":319,"correct":22},"平衡配筋梁的界限破坏",{"key":24,"text":321,"correct":22},"适筋梁破坏",{"key":28,"text":323,"correct":22},"少筋梁破坏",{"key":31,"text":325,"correct":26},"超筋梁破坏",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":33},927903,"已知矩形截面简支梁计算跨度ln＝8.5m，b＝350mm，h＝600mm，承受均布荷载设计值g+q＝12.3kN\u002Fm（包括梁自重），集中荷载设计值P＝210kN（见图2-28）。采用C30级混凝土，若箍筋为HPB300级钢筋，则仅配置箍筋时，所需箍筋为（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":26},"4φ8@150",{"key":24,"text":333,"correct":22},"4φ8@200",{"key":28,"text":335,"correct":22},"4φ8@250",{"key":31,"text":337,"correct":22},"4φ8@300",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},927904,"已知钢筋混凝土矩形截面梁，截面尺寸为b×h＝250mm×500mm，C25混凝土，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋，as＝35mm。 2.若弯矩设计值M＝90kN·m，混凝土强度等级C20，则受弯纵筋As为（ ）mm2。",[342,344,346,348],{"key":20,"text":343,"correct":22},"250.0",{"key":24,"text":345,"correct":26},"714.0",{"key":28,"text":347,"correct":22},"1250.0",{"key":31,"text":349,"correct":22},"2046.0",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":28,"analysis":33},927905,"已知钢筋混凝土矩形截面梁，截面尺寸为b×h＝250mm×500mm，C25混凝土，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋，as＝35mm。 3.在题（1）中，剪扭构件混凝土受扭承载力降低系数βt为（ ）。",[354,356,358,360],{"key":20,"text":355,"correct":22},"0.35",{"key":24,"text":357,"correct":22},"0.5",{"key":28,"text":359,"correct":26},"1.0",{"key":31,"text":361,"correct":22},"1.15",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":24,"analysis":33},927906,"已知钢筋混凝土矩形截面梁，截面尺寸为b×h＝250mm×500mm，C25混凝土，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋，as＝35mm。",[366,368,370,372],{"key":20,"text":367,"correct":22},"0.147；0.273",{"key":24,"text":369,"correct":26},"0.159；0.277",{"key":28,"text":371,"correct":22},"0.20；0.37",{"key":31,"text":373,"correct":22},"0.24；0.28",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":376,"answer":31,"analysis":33},927907,[377,379,381,383],{"key":20,"text":378,"correct":22},"201.9",{"key":24,"text":380,"correct":22},"215.1",{"key":28,"text":382,"correct":22},"218.8",{"key":31,"text":384,"correct":26},"299.6",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},927908,"已知钢筋混凝土矩形截面梁，截面尺寸为b×h＝250mm×500mm，C25混凝土，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋，as＝35mm。 6.若此梁的受弯纵筋As＝675.8mm2，受扭纵筋Astl＝218.4mm2，受扭箍筋Astl\u002Fs＝0.2mm2\u002Fmm，受剪箍筋Asv\u002Fs＝0.37mm2\u002Fmm，则此梁最后纵筋配筋与下列哪一项最为接近？（ ）",[389,390,391,392],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":20,"analysis":33},927909,"已知钢筋混凝土矩形截面梁，截面尺寸为b×h＝250mm×500mm，C25混凝土，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋，as＝35mm。 7.题（6）中，此梁最后箍筋配筋最接近于（ ）。",[397,399,401,403],{"key":20,"text":398,"correct":26},"2φ8@150",{"key":24,"text":400,"correct":22},"2φ8@200",{"key":28,"text":402,"correct":22},"2φ10@150",{"key":31,"text":404,"correct":22},"2φ10@200",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":31,"analysis":33},927910,"梁的正截面破坏形式有适筋梁破坏、超筋梁破坏、少筋梁破坏，它们的破坏性质是（ ）。",[409,411,413,415],{"key":20,"text":410,"correct":22},"都属于塑性破坏",{"key":24,"text":412,"correct":22},"都属于脆性破坏",{"key":28,"text":414,"correct":22},"适筋梁、超筋梁属脆性破坏，少筋梁属塑性破坏",{"key":31,"text":416,"correct":26},"适筋梁属延性破坏，超筋梁、少筋梁属脆性破坏",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":33},927911,"某简支在砖墙上的现浇钢筋混凝土平板（见图），板厚h=100mm，as=20mm。 2.若题（1）中其他条件不变，跨中最大弯矩设计值M=3.28kN·m，则As接近于（ ）mm2。",[421,423,425,427],{"key":20,"text":422,"correct":22},"272.0",{"key":24,"text":424,"correct":26},"200.0",{"key":28,"text":426,"correct":22},"190.5",{"key":31,"text":428,"correct":22},"139.7",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":24,"analysis":33},927912,"某混凝土单筋矩形截面简支梁，截面尺寸和配筋如图所示，采用C30混凝土，HRB335纵筋，环境类别为二a类。 3.若考虑架立筋2Φ14为受压钢筋，则该梁承受的弯矩设计值能提高（ ）。",[433,435,437,439],{"key":20,"text":434,"correct":22},"1%",{"key":24,"text":436,"correct":26},"3%",{"key":28,"text":438,"correct":22},"5%",{"key":31,"text":440,"correct":22},"7%",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":20,"analysis":33},927913,"某预制的钢筋混凝土简支空心板，截面形状尺寸如图所示。混凝土强度等级为C30，钢筋为HRB400，γ0=1.0。跨中最大弯矩设计值Md=3.6×108N·mm，采用绑扎钢筋骨架，设一层受拉主筋，受拉边缘至钢筋重心的距离as=40mm。 1.将空心板的圆孔换算成等效的矩形孔，设圆孔的直径为 D，方孔的宽度和高度分别为bk和hk，等效矩形孔尺寸hk（mm）和bk（mm）最接近于（ ）项数值。",[445,447,449,451],{"key":20,"text":446,"correct":26},"259.8；272",{"key":24,"text":448,"correct":22},"259.8；316",{"key":28,"text":450,"correct":22},"272；259.8",{"key":31,"text":452,"correct":22},"272；316",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":24,"analysis":33},927914,"非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 1.在静载和活载共同作用下的支座反力设计值RA最接近于（ ）kN。",[457,459,461,463],{"key":20,"text":458,"correct":22},"60.30",{"key":24,"text":460,"correct":26},"75.24",{"key":28,"text":462,"correct":22},"76.36",{"key":31,"text":464,"correct":22},"78.12",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":33},927915,"非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 2.在静载和活载共同作用下，上弦杆S1的内力设计值最接近于（ ）kN。",[469,471,473,475],{"key":20,"text":470,"correct":22},"134.83",{"key":24,"text":472,"correct":26},"140.20",{"key":28,"text":474,"correct":22},"145.57",{"key":31,"text":476,"correct":22},"151.69",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":28,"analysis":33},927916,"非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 3.若上弦杆截面尺寸均为b×h＝250mm×250mm，采用C35级混凝土，纵向受力钢筋采用HRB335级。设上弦杆S3轴向力设计值N＝148.72kN，计算长度l0＝2500mm，则承载力计算时其全截面纵向受力钢筋面积最接近于（ ）。",[481,482,483,484],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":24,"analysis":33},927917,"非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 4.若下弦杆截面尺寸均为b×h＝250mm×250mm，采用C35级混凝土，纵向受力钢筋采用HRB335级。设下弦杆S4轴向力标准值Nk＝181.6kN，全截面纵向受力钢筋为Φ14，混凝土保护层c＝30mm，则杆件的最大裂缝宽度最接近于（ ）mm。",[489,491,493,495],{"key":20,"text":490,"correct":22},"0.131",{"key":24,"text":492,"correct":26},"0.138",{"key":28,"text":494,"correct":22},"0.142",{"key":31,"text":496,"correct":22},"0.149",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":24,"analysis":33},927918,"某钢筋混凝土柱，截面尺寸为300mm×500mm，混凝土强度等级为C30，纵向受力钢筋为HRB400，纵向钢筋合力点至截面近边缘的距离as＝a s′＝40mm。 1.设柱的计算长度为3m，承受的轴心压力设计值N＝1100kN，弯矩设计值M＝250kN·m，则轴向压力作用点至纵向受拉钢筋的合力点的距离e（mm）最接近于（ ）项数值。",[501,503,505,507],{"key":20,"text":502,"correct":22},"380",{"key":24,"text":504,"correct":26},"452",{"key":28,"text":506,"correct":22},"469",{"key":31,"text":508,"correct":22},"484",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":28,"analysis":33},927919,"某钢筋混凝土柱，截面尺寸为300mm×500mm，混凝土强度等级为C30，纵向受力钢筋为HRB400，纵向钢筋合力点至截面近边缘的距离as＝a s′＝40mm。 2.设柱截面的受压和受拉钢筋的配筋面积均为1256mm2，受拉区纵向钢筋的等效直径deq＝20mm，混凝土保护层厚度c＝30mm，按荷载效应标准组合计算的轴力Nk＝500kN，弯矩值Mk＝180kN·m，构件计算长度l0＝4000mm，钢筋的相对黏结特性系数υ＝1.0，则按荷载效应的标准组合计算的纵向受拉钢筋的等效应力σsk（N\u002Fmm2）与（ ）项数值最为接近。",[513,515,517,519],{"key":20,"text":514,"correct":22},"193",{"key":24,"text":516,"correct":22},"206",{"key":28,"text":518,"correct":26},"225",{"key":31,"text":520,"correct":22},"290",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":31,"analysis":33},927920,"某钢筋混凝土柱，截面尺寸为300mm×500mm，混凝土强度等级为C30，纵向受力钢筋为HRB400，纵向钢筋合力点至截面近边缘的距离as＝a s′＝40mm。 3.设轴向压力作用点至纵向受拉钢筋合力点的距离e＝569mm，受拉纵筋面积As＝1521mm2，受拉区纵向钢筋的等效直径deq＝22mm，等效应力σsk＝186N\u002Fmm2，构件直接承受重复动力荷载，其余条件同上题，则构件的最大裂缝宽度wmax（mm）与（ ）项数值最为接近。",[525,527,529,531],{"key":20,"text":526,"correct":22},"0.143",{"key":24,"text":528,"correct":22},"0.174",{"key":28,"text":530,"correct":22},"0.221",{"key":31,"text":532,"correct":26},"0.281",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":28,"analysis":33},927921,"有一承受非恒载为主的钢筋混凝土框架柱，安全等级为二级，矩形截面尺寸b×h＝300mm×500mm，对称配筋，每侧各配有320的钢筋（钢筋为HRB335），混凝土强度等级为C25，纵向受拉钢筋合力点至截面近边的距离as＝40mm，柱的计算长度为l0＝4.5m。 1.该柱在某荷载组合下，其正截面受压承载力计算中，受压区高度x＝290mm，则在该组合内力下，柱的受拉主筋的应力σs（N\u002Fmm2）最接近于（ ）项数值。",[537,539,541,543],{"key":20,"text":538,"correct":22},"178",{"key":24,"text":540,"correct":22},"195",{"key":28,"text":542,"correct":26},"204",{"key":31,"text":544,"correct":22},"252",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},927922,"有一承受非恒载为主的钢筋混凝土框架柱，安全等级为二级，矩形截面尺寸b×h＝300mm×500mm，对称配筋，每侧各配有320的钢筋（钢筋为HRB335），混凝土强度等级为C25，纵向受拉钢筋合力点至截面近边的距离as＝40mm，柱的计算长度为l0＝4.5m。 2.柱正截面受压承载力计算中，已知该柱为小偏心受压。假定该框架柱偏心受压时有轴向压力设计值N＝500kN，柱两端配有双肢箍φ8@150，箍筋等级为HPB300，计算截面的剪跨比λ＝3，则该柱斜截面受剪承载力设计值（kN）与（ ）项数值最为接近。",[549,551,553,555],{"key":20,"text":550,"correct":22},"176.8",{"key":24,"text":552,"correct":26},"198.8",{"key":28,"text":554,"correct":22},"206.8",{"key":31,"text":556,"correct":22},"212.3",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":31,"analysis":33},927923,"圆形截面轴心受压柱，直径d＝500mm，计算长度l0＝5200mm。受轴心压力设计值N＝4500kN，混凝土强度等级为C30，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋。 1.按配有普通纵筋和箍筋柱计算，所需纵向受压钢筋面积As′最接近（ ）mm2。",[561,563,565,567],{"key":20,"text":562,"correct":22},"7798.19",{"key":24,"text":564,"correct":22},"7981.36",{"key":28,"text":566,"correct":22},"8184.51",{"key":31,"text":568,"correct":26},"8594.17",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":20,"analysis":33},927924,"圆形截面轴心受压柱，直径d＝500mm，计算长度l0＝5200mm。受轴心压力设计值N＝4500kN，混凝土强度等级为C30，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋。 2.若按配有螺旋箍筋的柱计算，箍筋用12@50，纵向受压钢筋用1825，A s′＝8835.7mm2。柱的承载力Nu最接近（ ）kN。",[573,575,577,579],{"key":20,"text":574,"correct":26},"4667.2",{"key":24,"text":576,"correct":22},"5640.8",{"key":28,"text":578,"correct":22},"6200.6",{"key":31,"text":580,"correct":22},"7000.8",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":28,"analysis":33},927925,"从混凝土受压构件的承载力N-M相关关系中得出的下述结论正确的是（ ）。",[585,587,589,591],{"key":20,"text":586,"correct":22},"当M一定时，对小偏压柱，应取N小的组合控制截面设计",{"key":24,"text":588,"correct":22},"当M一定时，对大偏压柱，应取N大的组合控制截面设计",{"key":28,"text":590,"correct":26},"当N一定时，无论大、小偏压柱都要取M尽可能大的组合控制截面设计",{"key":31,"text":592,"correct":22},"轴压时的受压承载力最大，Nmax＝N0；纯弯时的受弯承载力最大，Mmax＝M0",{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":28,"analysis":33},927926,"某钢筋混凝土柱的截面尺寸300mm×500mm，柱计算长度l0＝6m，轴向力设计值N＝1300kN，弯矩设计值M＝253kN·m。采用混凝土强度等级为C20，纵向受力钢筋采用HRB335级。 1.若设计成对称配筋，相对受压区高度ξ应为（ ）。",[597,599,601,603],{"key":20,"text":598,"correct":22},"0.418",{"key":24,"text":600,"correct":22},"0.550",{"key":28,"text":602,"correct":26},"0.679",{"key":31,"text":604,"correct":22},"0.981",[606,609,612,615,618,621],{"id":15,"name":607,"category":7,"favorite":608},"领导干部任职前廉政法规知识测试题",92,{"id":610,"name":611,"category":7,"favorite":15},595,"建筑结构与设备",{"id":613,"name":614,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":616,"name":617,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":619,"name":620,"category":7,"favorite":8},534,"BIM工程师",{"id":622,"name":620,"category":7,"favorite":8},535]