[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-599-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":309},{"id":5,"name":6,"category":7,"favorite":8},599,"(结构) 专业考试二级","建筑工程",0,15,50,724,[13,34,46,58,69,81,93,105,117,129,141,153,165,177,189,201,213,225,237,249,261,273,285,297],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},928528,1,"单选题","某普通住宅，采用现浇钢筋混凝土部分框支剪力墙结构，房屋高度为40.9m。地下1层，地上13层，首层～三层层高分别为4.5m、4.2m、3.9m，其余各层层高均为2.8m，抗震设防烈度为7度，Ⅱ类建筑场地。第3层设转换层，纵横向均有落地剪力墙，地下一层顶板可作为上部结构的嵌固部位。[2013年真题] 3.假定，首层某根框支角柱C1，在地震作用下，其柱底轴力标准值NEk=1680kN；在重力荷载代表值作用下，其柱底轴力标准值NGE=2950kN。框支柱抗震等级为一级，不考虑风荷载。试问，考虑地震作用组合进行截面配筋计算时，柱C1柱底的轴力最大设计值（kN）与下列何项数值最为接近？（ ）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","5720",false,{"key":24,"text":25,"correct":22},"B","6160",{"key":27,"text":28,"correct":29},"C","6820",true,{"key":31,"text":32,"correct":22},"D","7150","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},928529,"下列关于高层混凝土结构的相关论述，何项观点不符合相关规范、规程要求？（ ）[2014年真题]",[38,40,42,44],{"key":20,"text":39,"correct":29},"房屋高度大于60m的高层建筑，设计时应按基本风压的1.1倍采用",{"key":24,"text":41,"correct":22},"无论采用何种结构体系，结构的平面和竖向布置宜使结构具有合理的刚度、质量和承载力分布，避免因局部突变和扭转效应而形成薄弱部位",{"key":27,"text":43,"correct":22},"钢筋混凝土高层建筑结构，在水平力作用下，只要结构的弹性等效侧向刚度和重力荷载之间的关系满足一定的限值，可不考虑重力二阶效应的不利影响",{"key":31,"text":45,"correct":22},"抗震设计时，钢筋混凝土柱轴压比中的轴向压力，采用地震作用组合的轴向压力设计值",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},928530,"某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40",[50,52,54,56],{"key":20,"text":51,"correct":29},"1320、400",{"key":24,"text":53,"correct":22},"1400、400",{"key":27,"text":55,"correct":22},"1320、378",{"key":31,"text":57,"correct":22},"1680、432",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":60,"answer":24,"analysis":33},928531,[61,63,65,67],{"key":20,"text":62,"correct":22},"107",{"key":24,"text":64,"correct":29},"157",{"key":27,"text":66,"correct":22},"200",{"key":31,"text":68,"correct":22},"250",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":24,"analysis":33},928532,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 1.假定，该框架结构层侧向刚度无突变，底层屈服强度系数为0.45，第二层的楼层屈服强度系数为0.55，框架底层柱轴压比均不小于0.5。若不考虑箍筋配置的影响，试问，罕遇地震作用下按弹性方法计算的底层层间位移Δue（mm）不超过下列何值时，方能满足规范对结构薄弱层层间弹塑性位移的要求？（ ）",[73,75,77,79],{"key":20,"text":74,"correct":22},"47.5",{"key":24,"text":76,"correct":29},"50.5",{"key":27,"text":78,"correct":22},"53.5",{"key":31,"text":80,"correct":22},"96.0",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":20,"analysis":33},928533,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 2.已知二层顶某跨框架边梁A B，在地震及各荷载作用下梁B端截面所产生的弯矩标准值如下：永久荷载下MGk=-65kN·m；楼面活荷载下MQk=-20kN·m；风荷载下Mwk=±70kN·m；水平地震作用下MEhk=±260kN·m。试问，满足规范要求时，AB梁B端截面考虑地震作用组合的最不利组合弯矩设计值MB（kN·m）与下列何项数值最为接近？（ ）",[85,87,89,91],{"key":20,"text":86,"correct":29},"-430",{"key":24,"text":88,"correct":22},"-440",{"key":27,"text":90,"correct":22},"-530",{"key":31,"text":92,"correct":22},"-540",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},928534,"一单层平面框架（见图），由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m。 1.由屋顶均布活荷载标准值产生的弯矩标准值MDqk=30kN·m，则D点的弯矩设计值MD最接近于（ ）kN·m。",[97,99,101,103],{"key":20,"text":98,"correct":22},"130",{"key":24,"text":100,"correct":29},"102",{"key":27,"text":102,"correct":22},"96.9",{"key":31,"text":104,"correct":22},"95",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":27,"analysis":33},928535,"一单层平面框架（见图），由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m。 现尚需计及如图所示由风荷载产生的D点弯矩标准值MDwk=25kN·m，由此算得D点组合后的弯矩设计值MD最接近于（ ）kN·m。（不采用简化规则）",[109,111,113,115],{"key":20,"text":110,"correct":22},"117.9",{"key":24,"text":112,"correct":22},"123.0",{"key":27,"text":114,"correct":29},"124.4",{"key":31,"text":116,"correct":22},"140.0",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},928536,"某城市郊区有一30层的一般钢筋混凝土高层建筑，如图所示。地面以上高度为100m，迎风面宽度为25m，按50年重现期的基本风压w0=0.60kN\u002Fm2，风荷载体型系数为1.3。 3.若该建筑物位于一高度为45m的山坡顶部，如图6-30所示，建筑屋面D处的风压高度变化系数μz最接近于（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":22},"1.997",{"key":24,"text":124,"correct":29},"2.290",{"key":27,"text":126,"correct":22},"2.351",{"key":31,"text":128,"correct":22},"2.616",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":20,"analysis":33},928537,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 1.在重力荷载代表值作用下，已知三层横梁的支座弯矩如图所示。当考虑梁端塑性变形内力重分布而对梁端负弯矩进行调幅，并取调幅系数为0.8时，则边横梁的跨中弯矩设计值M最接近于（ ）kN·m。",[133,135,137,139],{"key":20,"text":134,"correct":29},"73.5",{"key":24,"text":136,"correct":22},"88",{"key":27,"text":138,"correct":22},"93",{"key":31,"text":140,"correct":22},"111",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":33},928538,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 2.连梁的容许剪力设计值最接近于（ ）kN。",[145,147,149,151],{"key":20,"text":146,"correct":29},"349",{"key":24,"text":148,"correct":22},"387",{"key":27,"text":150,"correct":22},"402",{"key":31,"text":152,"correct":22},"465",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},928539,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 3.连梁配置的箍筋最接近于（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"双肢φ8@110",{"key":24,"text":160,"correct":22},"双肢φ8@200",{"key":27,"text":162,"correct":22},"双肢φ8@150",{"key":31,"text":164,"correct":29},"双肢φ8@100",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":27,"analysis":33},928540,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 4.连梁每侧的腰筋配置最接近于（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"4φ10",{"key":24,"text":172,"correct":22},"4φ8",{"key":27,"text":174,"correct":29},"4φ12",{"key":31,"text":176,"correct":22},"3φ10",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":27,"analysis":33},928541,"下列各项不属于偶然作用的是（ ）。",[181,183,185,187],{"key":20,"text":182,"correct":22},"罕遇地震",{"key":24,"text":184,"correct":22},"爆炸力、撞击力",{"key":27,"text":186,"correct":29},"施工检修荷载",{"key":31,"text":188,"correct":22},"龙卷风",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":33},928542,"某房间有可能活动的人很集中，有时很挤或有较重的设备，则楼面均布活荷载标准值（kN\u002Fm2）比较合适的取值范围是（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":22},"2.5～3.0",{"key":24,"text":196,"correct":29},"3.5～4.0",{"key":27,"text":198,"correct":22},"4.5～5.5",{"key":31,"text":200,"correct":22},"6.0～7.0",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":31,"analysis":33},928543,"下列全为不燃烧建筑材料的是（ ）。 Ⅰ．木材 Ⅱ．钢材 Ⅲ．塑料 Ⅳ．混凝土 Ⅴ．烧结多孔砖 Ⅵ．花岗岩",[205,207,209,211],{"key":20,"text":206,"correct":22},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"key":24,"text":208,"correct":22},"Ⅰ、Ⅱ、Ⅳ、Ⅴ",{"key":27,"text":210,"correct":22},"Ⅱ、Ⅲ、Ⅴ、Ⅵ",{"key":31,"text":212,"correct":29},"Ⅱ、Ⅳ、Ⅴ、Ⅵ",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":27,"analysis":33},928544,"下列各项中，（ ）不属于超过承载能力极限状态的情形。",[217,219,221,223],{"key":20,"text":218,"correct":22},"地基失稳",{"key":24,"text":220,"correct":22},"墙、柱压屈失稳",{"key":27,"text":222,"correct":29},"构件变形过大，超过规范规定的挠度或水平变位限值",{"key":31,"text":224,"correct":22},"结构作为刚体失去平衡，如挑梁的倾覆",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":31,"analysis":33},928545,"关于钢材高温性能，下列叙述不正确的是（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":22},"低碳钢500℃时约为常温强度的1\u002F2，600℃约为1\u002F3",{"key":24,"text":232,"correct":22},"高强钢丝350℃时约为常温强度的1\u002F2，400℃约为1\u002F3",{"key":27,"text":234,"correct":22},"低碳钢300～350℃时，普通低合金钢400～450℃时，钢材徐变增大",{"key":31,"text":236,"correct":29},"冷加工钢筋高温性能和低碳钢相似",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":31,"analysis":33},928546,"关于结构承载能力极限状态基本组合中的可变荷载效应控制的组合设计表达式，即《建筑结构可靠度设计统一标准》（GB 50068—2001）式（7.0.2-1）或式（7.0.2-3），下列叙述错误的是（ ）。 A、永久荷载分项系数γ",[241,243,245,247],{"key":20,"text":242,"correct":22},"当其对结构不利时应取1.2，有利时不应大于1.0（挑梁抗倾覆验算取0.8）",{"key":24,"text":244,"correct":22},"可变荷载分项系数γQ1和γQi当其对结构不利时，一般应取1.4（对标准值大于4kN\u002Fm2的工业房屋楼面活荷载应取1.3），有利时应取0",{"key":27,"text":246,"correct":22},"ψci为第i个可变荷载的组合值系数，其值不应大于1，并由荷载规范按不同荷载给出",{"key":31,"text":248,"correct":29},"ψ为框、排架的简化设计表达式中采用的荷载组合系数，当有风荷载参与组合时取ψ=0.9",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":31,"analysis":33},928547,"关于荷载代表值的概念，下列叙述错误的是（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":22},"永久荷载标准值相当于其概率分布的0.5分位值",{"key":24,"text":256,"correct":22},"楼面活荷载标准值相当于设计基准期最大荷载平均值μqt加α倍标准差σqt",{"key":27,"text":258,"correct":22},"对住宅、办公楼楼面活荷载，荷载准永久值相当于取其设计基准期任意时点荷载概率分布的0.5分位值",{"key":31,"text":260,"correct":29},"可变荷载的荷载频遇值相当于取其设计基准期任意时点荷载概率分布的0.1分位值",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":27,"analysis":33},928548,"关于正常使用极限状态下荷载效应组合设计值S的表达式，下列叙述不正确的是（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"所有组合的第一项，即永久荷载效应采用标准值效应",{"key":24,"text":268,"correct":22},"对于标准组合，除可变荷载效应最大的取标准值以外，其余均采用可变荷载效应的组合值",{"key":27,"text":270,"correct":29},"对于频遇组合，可变荷载效应采用荷载的频遇值效应",{"key":31,"text":272,"correct":22},"对于准永久组合，可变荷载效应采用荷载的准永久值效应",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":27,"analysis":33},928549,"某框架结构钢筋混凝土办公楼，安全等级为二级，梁板布置如图所示。框架的抗震等级为三级，混凝土强度等级为C30，梁板均采用HRB400级钢筋。板面恒载标准值5.0kN／m2（含板自重），活荷载标准值2.0kN／m2，梁上恒荷载标准值10.0kN／m（含梁及梁上墙自重）。试问，配筋设计时，次梁L1上均布线荷载的组合设计值q（kN／m），与下列何项数值最为接近？（ ）[2014年真题] 提示：荷载传递按单向板考虑。",[277,279,281,283],{"key":20,"text":278,"correct":22},"37",{"key":24,"text":280,"correct":22},"38",{"key":27,"text":282,"correct":29},"39",{"key":31,"text":284,"correct":22},"40",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":24,"analysis":33},928550,"某一层吊车的两跨厂房，每跨厂房各设有3台A5工作级别的吊车。试问，通常情况下，进行该两跨厂房的每个排架计算时，参与组合的多台吊车的水平荷载标准值的折减系数应取下列何项数值？（ ）[2012年真题]",[289,291,293,295],{"key":20,"text":290,"correct":22},"0.95",{"key":24,"text":292,"correct":29},"0.9",{"key":27,"text":294,"correct":22},"0.85",{"key":31,"text":296,"correct":22},"0.8",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":24,"analysis":33},928551,"关于屋面活荷载的规定，下列叙述不正确的是（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"屋面均布活荷载，不应与雪荷载同时组合",{"key":24,"text":304,"correct":29},"不上人的屋面，当施工或维修荷载较大时，应按实际情况采用；不同结构应按有关规范规定，可将标准值0.5kN\u002Fm2作0.3kN\u002Fm2的增减",{"key":27,"text":306,"correct":22},"上人的屋面，当兼作其他用途时，应按相应楼面活荷载采用",{"key":31,"text":308,"correct":22},"对于因屋面排水不畅、堵塞等引起的积水荷载，应采取构造措施加以防止",[310,313,316,319,322,325],{"id":15,"name":311,"category":7,"favorite":312},"领导干部任职前廉政法规知识测试题",92,{"id":314,"name":315,"category":7,"favorite":15},595,"建筑结构与设备",{"id":317,"name":318,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":320,"name":321,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":323,"name":324,"category":7,"favorite":8},534,"BIM工程师",{"id":326,"name":324,"category":7,"favorite":8},535]