[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-599-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":609},{"id":5,"name":6,"category":7,"favorite":8},599,"(结构) 专业考试二级","建筑工程",0,14,50,724,[13,34,46,57,69,81,93,105,117,129,141,153,165,177,189,201,213,225,234,246,258,270,282,290,302,310,322,334,346,358,370,382,394,406,418,430,442,454,466,478,490,502,514,525,537,549,561,573,585,597],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},928478,1,"单选题","一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 4.若二层中柱截面600mm×600mm混凝土C30在重力荷载代表值作用下NG=2200kN，在水平地震作用下该柱的附加轴向力标准值为NEk=±150kN，柱混凝土保护层厚度为30mm，箍筋采用HPB235钢筋四肢，其加密区内的箍筋体积配箍率ρv不宜小于（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","0.6%",false,{"key":24,"text":25,"correct":26},"B","0.95%",true,{"key":28,"text":29,"correct":22},"C","1.0%",{"key":31,"text":32,"correct":22},"D","1.2%","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},928479,"某三跨框架结构，抗震等级为二级，边跨跨度为5.7m，框架梁截面宽250mm，高600mm，柱宽为500mm，纵筋采用HRB335钢，箍筋采用HPB300钢，混凝土强度等级为C30，重力荷载引起的剪力VGb=135.2kN。在重力荷载和地震作用组合下作用于边跨一层梁上的弯矩为： 梁左端：Mmax=210kN·m，－Mmax=－420kN·m； 梁右端：Mmax=175kN·m，－Mmax=－360kN·m； 梁跨中：Mmax=180kN·m； 边跨梁：V=230kN。 1.计算梁跨中截面正截面所需纵筋As，最接近于（ ）mm2。",[38,40,42,44],{"key":20,"text":39,"correct":22},"393",{"key":24,"text":41,"correct":22},"685",{"key":28,"text":43,"correct":26},"850",{"key":31,"text":45,"correct":22},"1170",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},928480,"某三跨框架结构，抗震等级为二级，边跨跨度为5.7m，框架梁截面宽250mm，高600mm，柱宽为500mm，纵筋采用HRB335钢，箍筋采用HPB300钢，混凝土强度等级为C30，重力荷载引起的剪力VGb=135.2kN。在重力荷载和地震作用组合下作用于边跨一层梁上的弯矩为： 梁左端：Mmax=210kN·m，－Mmax=－420kN·m； 梁右端：Mmax=175kN·m，－Mmax=－360kN·m； 梁跨中：Mmax=180kN·m； 边跨梁：V=230kN。 2.若梁左端梁底已配置2φ25的钢筋，则梁顶钢筋As最接近于（ ）mm2。",[50,51,53,55],{"key":20,"text":45,"correct":22},{"key":24,"text":52,"correct":22},"1672",{"key":28,"text":54,"correct":22},"1964",{"key":31,"text":56,"correct":26},"1992",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":28,"analysis":33},928481,"某三跨框架结构，抗震等级为二级，边跨跨度为5.7m，框架梁截面宽250mm，高600mm，柱宽为500mm，纵筋采用HRB335钢，箍筋采用HPB300钢，混凝土强度等级为C30，重力荷载引起的剪力VGb=135.2kN。在重力荷载和地震作用组合下作用于边跨一层梁上的弯矩为： 梁左端：Mmax=210kN·m，－Mmax=－420kN·m； 梁右端：Mmax=175kN·m，－Mmax=－360kN·m； 梁跨中：Mmax=180kN·m； 边跨梁：V=230kN。 3.计算该框架梁的剪力设计值Vb，最接近于（ ）kN。",[61,63,65,67],{"key":20,"text":62,"correct":22},"230",{"key":24,"text":64,"correct":22},"257.5",{"key":28,"text":66,"correct":26},"272.5",{"key":31,"text":68,"correct":22},"282.7",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":28,"analysis":33},928482,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 1.假定结构的基本自振周期T1＝0.65s，结构阻尼比ζ＝0.05。结构总水平地震作用标准值FEk最接近于（ ）kN。",[73,75,77,79],{"key":20,"text":74,"correct":22},"2492",{"key":24,"text":76,"correct":22},"3271",{"key":28,"text":78,"correct":26},"4217",{"key":31,"text":80,"correct":22},"4555",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},928483,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 2.若该框架为钢筋混凝土结构，结构的基本自振周期T1＝0.85s，总水平地震作用标准值FEk＝3304kN，作用于顶部附加水平地震作用标准值ΔF6最接近于（ ）kN。",[85,87,89,91],{"key":20,"text":86,"correct":22},"153",{"key":24,"text":88,"correct":26},"258",{"key":28,"text":90,"correct":22},"466",{"key":31,"text":92,"correct":22},"525",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":24,"analysis":33},928484,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 3.若已知结构总水平地震作用标准值FEk＝3126kN，顶部附加水平地震作用ΔF6=256kN，作用于G5处的地震作用标准值F5最接近于（ ）kN。",[97,99,101,103],{"key":20,"text":98,"correct":22},"565",{"key":24,"text":100,"correct":26},"697",{"key":28,"text":102,"correct":22},"756",{"key":31,"text":104,"correct":22},"914",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},928485,"某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 4.若该框架为钢结构，结构的基本自振周期T1＝1.2s，结构阻尼比ζ＝0.035，其他数据不变，结构总水平地震作用标准值FEk最接近于（ ）kN。",[109,111,113,115],{"key":20,"text":110,"correct":22},"2413",{"key":24,"text":112,"correct":26},"2628",{"key":28,"text":114,"correct":22},"2839",{"key":31,"text":116,"correct":22},"3140",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":31,"analysis":33},928486,"某抗震等级为二级的高层框架结构，首层的梁柱中节点，横向左、右侧梁截面尺寸及纵向梁截面尺寸如图所示。梁柱混凝土强度等级为C30，fc=14.3MPa，ft=1.43MPa，as=as′=60mm。节点左侧梁端弯矩设计值 右侧梁端弯矩设计值 上柱底部考虑地震作用组合的轴向压力设计值N=3484.0kN，节点上下层柱反弯点之间的距离Hc=4.65m。 3.下列关于节点核心区的箍筋配置最合适的是（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":22},"双向4肢φ8@100",{"key":24,"text":124,"correct":22},"双向4肢φ8@120",{"key":28,"text":126,"correct":22},"双向4肢φ8@150",{"key":31,"text":128,"correct":26},"双向4肢φ10@100",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":28,"analysis":33},928487,"某抗震等级为二级的高层框架结构，首层的梁柱中节点，横向左、右侧梁截面尺寸及纵向梁截面尺寸如图所示。梁柱混凝土强度等级为C30，fc=14.3MPa，ft=1.43MPa，as=as′=60mm。节点左侧梁端弯矩设计值 右侧梁端弯矩设计值 上柱底部考虑地震作用组合的轴向压力设计值N=3484.0kN，节点上下层柱反弯点之间的距离Hc=4.65m。 2.节点的容许剪力设计值[Vj]最接近于（ ）kN。",[133,135,137,139],{"key":20,"text":134,"correct":22},"1816.94",{"key":24,"text":136,"correct":22},"2059.20",{"key":28,"text":138,"correct":26},"2725.41",{"key":31,"text":140,"correct":22},"3088.80",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":24,"analysis":33},928488,"某抗震等级为二级的高层框架结构，首层的梁柱中节点，横向左、右侧梁截面尺寸及纵向梁截面尺寸如图所示。梁柱混凝土强度等级为C30，fc=14.3MPa，ft=1.43MPa，as=as′=60mm。节点左侧梁端弯矩设计值 右侧梁端弯矩设计值 上柱底部考虑地震作用组合的轴向压力设计值N=3484.0kN，节点上下层柱反弯点之间的距离Hc=4.65m。 1.节点的剪力设计值Vj最接近于（ ）kN。",[145,147,149,151],{"key":20,"text":146,"correct":22},"973.52",{"key":24,"text":148,"correct":26},"1182.43",{"key":28,"text":150,"correct":22},"1414.96",{"key":31,"text":152,"correct":22},"1476.48",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":28,"analysis":33},928489,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，其中间的剪力墙的计算简图如图6-35所示。在风荷载（标准值）作用下，试采用近似分析方法（将两个墙肢视为一拉一压，且其合力作用在墙肢的中心线上），估算每根连梁的平均支座弯矩设计值Mb最接近于（ ）kN·m。",[157,159,161,163],{"key":20,"text":158,"correct":22},"±114",{"key":24,"text":160,"correct":22},"±126",{"key":28,"text":162,"correct":26},"±160",{"key":31,"text":164,"correct":22},"±176",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":24,"analysis":33},928490,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，层高2.8m，房屋宽15.7m，地面粗糙度D类。混凝土强度等级为C30，纵向钢筋采用HRB335钢，箍筋采用HPB300钢。as=a s′=35mm。 1.工程所在场地的地基土的构成如表所示。 若有抗震要求时，确定其建筑场地类别为（ ）类。",[169,171,173,175],{"key":20,"text":170,"correct":22},"Ⅰ",{"key":24,"text":172,"correct":26},"Ⅱ",{"key":28,"text":174,"correct":22},"Ⅲ",{"key":31,"text":176,"correct":22},"Ⅳ",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},928491,"某建造于大城市市区的28层公寓，采用钢筋混凝土剪力墙结构体系。平面为矩形，共6个开间，横向剪力墙间距为8.1m，层高2.8m，房屋宽15.7m，地面粗糙度D类。混凝土强度等级为C30，纵向钢筋采用HRB335钢，箍筋采用HPB300钢。as=a s′=35mm。 2.当未考虑非结构构件影响折减系数时，该建筑物的横向自振周期T1最接近于（ ）s。",[181,183,185,187],{"key":20,"text":182,"correct":22},"3.4",{"key":24,"text":184,"correct":22},"2.8",{"key":28,"text":186,"correct":22},"2.2",{"key":31,"text":188,"correct":26},"0.97",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":28,"analysis":33},928492,"有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 1.连梁配置箍筋时的剪力设计值最接近于（ ）kN。",[193,195,197,199],{"key":20,"text":194,"correct":22},"150",{"key":24,"text":196,"correct":22},"165",{"key":28,"text":198,"correct":26},"180",{"key":31,"text":200,"correct":22},"195",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":33},928493,"有一幢高层框架—剪力墙结构，层数为22层，高度80m，抗震设防烈度8度，Ⅲ类场地，设计地震分组为一组，总重力荷载代表值为∑Gi=286000kN，基本自振周期T1=1.43s，则采用底部剪力法计算底部剪力标准值FEk=（ ）kN。",[205,207,209,211],{"key":20,"text":206,"correct":22},"16159.1",{"key":24,"text":208,"correct":26},"13735.2",{"key":28,"text":210,"correct":22},"12349.5",{"key":31,"text":212,"correct":22},"10537",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":31,"analysis":33},928494,"某拟建的高度为59m的16层现浇钢筋混凝土框剪结构，质量和刚度沿高度分布比较均匀，对风荷载不敏感，其两种平面方案如图所示（单位m）。假设在如图所示的作用方向两种结构方案的基本自振周期相同。 1.当估算主体结构的风荷载效应时，方案a与方案b的风荷载标准值（kN\u002Fm2）之比，最接近于（ ）。 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）解题。",[217,219,221,223],{"key":20,"text":218,"correct":22},"1∶1",{"key":24,"text":220,"correct":22},"1∶1.15",{"key":28,"text":222,"correct":22},"1∶1.2",{"key":31,"text":224,"correct":26},"1.15∶1",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":28,"analysis":33},928495,"某拟建的高度为59m的16层现浇钢筋混凝土框剪结构，质量和刚度沿高度分布比较均匀，对风荷载不敏感，其两种平面方案如图所示（单位m）。假设在如图所示的作用方向两种结构方案的基本自振周期相同。 2.当估算围护结构风荷载时，方案a和方案b相同高度迎风面中点处单位面积风荷载比值，最接近于（ ）。 提示：按《建筑结构荷载规范》（GB 50009—2012）解题。",[229,231,232,233],{"key":20,"text":230,"correct":22},"1.5∶1",{"key":24,"text":224,"correct":22},{"key":28,"text":218,"correct":26},{"key":31,"text":222,"correct":22},{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":24,"analysis":33},928496,"某高层建筑有抗震设防的底层大空间剪力墙结构，转换层以上楼层层高2.7m，横向剪力墙有效截面面积Aw2=19.2m2；框支层层高3.6m，横向落地剪力墙有效截面面积Aw1=11.4m2，框支层全部柱总截面面积Ac=2.88m2，柱截面均为1200mm×1200mm，混凝土强度等级框支层为C40，上层C25。下列各项中上下层刚度比正确的是（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":22},"γ=1.64",{"key":24,"text":241,"correct":26},"γ=1.81",{"key":28,"text":243,"correct":22},"γ=1.88",{"key":31,"text":245,"correct":22},"γ=1.96",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},928497,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 1.计算多遇地震作用时，该结构的水平地震作用影响系数α最接近于（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":26},"0.0172",{"key":24,"text":253,"correct":22},"0.020",{"key":28,"text":255,"correct":22},"0.022",{"key":31,"text":257,"correct":22},"0.024",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":33},928498,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 2.抗震设计时，在水平地震作用下，对应于地震作用标准值的结构底部总剪力计算值为8800kN；对于地震作用标准值且未经调整的各层框架总剪力中，24层最大，其计算值为1600kN。则各楼层框架的剪力经调整后最接近于（ ）kN。",[262,264,266,268],{"key":20,"text":263,"correct":22},"1500",{"key":24,"text":265,"correct":26},"1760",{"key":28,"text":267,"correct":22},"1920",{"key":31,"text":269,"correct":22},"2400",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":31,"analysis":33},928499,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 3.外周边框架底层某中柱，截面700mm×700mm，混凝土强度等级C50（fc=23.1N\u002Fmm2），内置Q345型钢（fa=295N\u002Fmm2），地震作用组合的柱轴向压力设计值N=19000kN，剪跨比λ=2.4。当要求柱轴压比μN≤0.8时，其采用的型钢截面面积应最接近于（ ）mm2。",[274,276,278,280],{"key":20,"text":275,"correct":22},"15000",{"key":24,"text":277,"correct":22},"19500",{"key":28,"text":279,"correct":22},"36000",{"key":31,"text":281,"correct":26},"45720",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":33},928500,"某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 4.条件同题（3），当柱轴压比μN=0.8，该柱在箍筋加密区的纵向钢筋和箍筋，下列各项中，最接近有关规范、规程最低构造要求的是（ ）。",[286,287,288,289],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":33},928501,"某矩形框筒，平面尺寸如图所示，总高度102m，承受水平力q=20kN\u002Fm，框筒截面可简化成双槽形截面，该截面如图6-38所示。角柱为L形、截面面积A3=6.41m2、形心坐标y=0.90m。槽形截面惯性矩为3056.5m4。计算图中底层3号柱所受的轴力N3最接近于（ ）kN。",[294,296,298,300],{"key":20,"text":295,"correct":22},"1564.9",{"key":24,"text":297,"correct":22},"1711.4",{"key":28,"text":299,"correct":22},"1956.2",{"key":31,"text":301,"correct":26},"2094.8",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":28,"analysis":33},928502,"某框架—核心筒结构底层一连梁如图所示，连梁截面bb=400mm，hb=1800mm，混凝土强度等级C35，（fc=16.7N\u002Fmm2），水平地震作用组合连梁剪力设计值V=840kN，当连梁中交叉暗撑与水平线夹角为α（sinα=0.66）时，交叉暗撑采用HRB400钢。交叉暗撑计算所需纵向钢筋最接近于（ ）。",[306,307,308,309],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":26},{"key":31,"text":31,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":20,"analysis":33},928503,"某高层钢结构，按8度抗震设防。结构设中心支撑，支撑斜杆钢材采用Q345（fy=325N\u002Fmm2），构件横断面如图所示。则满足腹板宽厚比要求的腹板厚度t最接近于（ ）mm。 提示：按《高层民用建筑钢结构技术规程》（JGJ 99—98）设计。",[314,316,318,320],{"key":20,"text":315,"correct":26},"26",{"key":24,"text":317,"correct":22},"28",{"key":28,"text":319,"correct":22},"30",{"key":31,"text":321,"correct":22},"32",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":31,"analysis":33},928504,"某高度45m钢结构，建于抗震设防烈度8度区，地震加速度0.2g，设计分组为第一组，场地类别为Ⅲ类，结构基本周期为1.0s。则与结构基本周期相应的地震影响系数，最接近于（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"0.05479",{"key":24,"text":329,"correct":22},"0.0678",{"key":28,"text":331,"correct":22},"0.0780",{"key":31,"text":333,"correct":26},"0.08214",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":28,"analysis":33},928505,"某13层钢框架结构，箱形方柱截面如图所示，抗震设防烈度为8度，回转半径ix=iy=173mm，钢材采用Q345（fy=325N\u002Fmm2）。则满足规程要求的最大层高h，应最接近于（ ）mm。 提示： ①按《高层民用建筑钢结构技术规程》（JGJ 99—98）设计； ②柱子的计算长度取层高h。",[338,340,342,344],{"key":20,"text":339,"correct":22},"7800",{"key":24,"text":341,"correct":22},"8200",{"key":28,"text":343,"correct":26},"8800",{"key":31,"text":345,"correct":22},"9200",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":31,"analysis":33},928506,"关于柱轴压比限值的要求，下列各项不正确的是（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":22},"框支剪力墙结构，抗震等级属于一级的框支柱（包括框支角柱），其轴压比不宜大于0.60",{"key":24,"text":353,"correct":22},"框架—剪力墙结构，抗震等级属一级的框架柱，当剪力墙部分承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其框架柱轴压比不宜大于0.65",{"key":28,"text":355,"correct":22},"框架—核心筒结构，抗震等级属一级的框架柱，当核心筒结构承受的地震倾覆力矩大于结构总地震倾覆力矩的50%时，其框架柱轴压比不宜大于0.75",{"key":31,"text":357,"correct":26},"筒中筒结构，抗震等级属一级的密集柱，沿柱全高采用井字复合箍，箍筋间距100mm、肢距150mm、箍径12mm；其内筒承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其密集柱的轴压比不宜大于0.75",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":33},928507,"位于设防烈度8度，Ⅲ类场地，高58m的丙类钢筋混凝土框架—剪力墙结构房屋。在重力荷载代表值，水平风荷载及水平地震作用下第四层边柱的轴向力标准值分别为NG=4200kN，Nw=1200kN，NEh=500kN；柱截面为600mm×800mm，混凝土C40，fc=19.1N\u002Fmm2。第四层层高3.60m，横梁高600mm。经计算知剪力墙部分承受的地震倾覆力矩大于结构总地震倾覆力矩的50%较多。则该柱轴压比验算结果正确的是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":26},"μN=0.621＜0.80，符合规程要求",{"key":24,"text":365,"correct":22},"μN=0.644＜0.75，符合规程要求",{"key":28,"text":367,"correct":22},"μN=0.657＜0.80，符合规程要求",{"key":31,"text":369,"correct":22},"μN=0.657＜0.85，符合规程要求",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":28,"analysis":33},928508,"如图所示，在Ⅲ类场地上建一座高为100m的钢筋混凝土烟囱。设防烈度为7度，远震，Tg=0.55s，烟囱自重的标准值Gk=18738.8kN，筒身的重心C距基础顶面H0=37.7m。 2.假定该烟囱的基本周期为2.5s，试确定与之相应的水平地震影响系数与（ ）项数值最为接近。",[374,376,378,380],{"key":20,"text":375,"correct":22},"0.0154",{"key":24,"text":377,"correct":22},"0.016",{"key":28,"text":379,"correct":26},"0.0205",{"key":31,"text":381,"correct":22},"0.041",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":28,"analysis":33},928509,"如图所示，在Ⅲ类场地上建一座高为100m的钢筋混凝土烟囱。设防烈度为7度，远震，Tg=0.55s，烟囱自重的标准值Gk=18738.8kN，筒身的重心C距基础顶面H0=37.7m。 3.假定该烟囱基本自振周期T1=2.40s，α1=0.02124。其底部由水平地震作用标准值产生的地震剪力V0最接近于（ ）kN。",[386,388,390,392],{"key":20,"text":387,"correct":22},"367.10kN",{"key":24,"text":389,"correct":22},"340.50kN",{"key":28,"text":391,"correct":26},"338.31kN",{"key":31,"text":393,"correct":22},"328.67kN",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":20,"analysis":33},928510,"如图所示，在Ⅲ类场地上建一座高为100m的钢筋混凝土烟囱。设防烈度为7度，远震，Tg=0.55s，烟囱自重的标准值Gk=18738.8kN，筒身的重心C距基础顶面H0=37.7m。 1.试问烟囱的第一周期T1最接近于（ ）s。",[398,400,402,404],{"key":20,"text":399,"correct":26},"2.013",{"key":24,"text":401,"correct":22},"2.690",{"key":28,"text":403,"correct":22},"3.756",{"key":31,"text":405,"correct":22},"4.106",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":28,"analysis":33},928511,"图所示为一个8层钢筋混凝土框架结构的平面图。该建筑抗震烈度为8度，属于二级抗震等级。下列结构动力分析方法中，正确的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"只要作横向的平动振型抗震验算，因为纵向（y向）的抗侧刚度较弱",{"key":24,"text":413,"correct":22},"只要作横向的抗震验算和纵向的抗震验算",{"key":28,"text":415,"correct":26},"除作x、y向的平动振型的抗震验算外，还要作扭转振型的耦联计算",{"key":31,"text":417,"correct":22},"该结构属于简单的纯框架，层数也不高，用基底剪力法计算其横向的水平地震力，并按各榀框架的抗侧刚度进行分配",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},928512,"在设防烈度为6度至9度地区内的乙类、丙类高层建筑，应进行抗震设计，其地震作用计算按下列哪种做法才符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）的规定？（ ）",[422,424,426,428],{"key":20,"text":423,"correct":26},"各抗震设防的高层建筑结构均应计算地震作用",{"key":24,"text":425,"correct":22},"6度设防时，Ⅰ～Ⅲ类场地上的建筑不必计算，Ⅳ类场地上的较高建筑及7度至9度设防的建筑应按本地区设防烈度计算",{"key":28,"text":427,"correct":22},"6度不必计算，7度至9度设防的建筑应按本地区设防烈度计算",{"key":31,"text":429,"correct":22},"6度设防时Ⅰ、Ⅱ类场地上的建筑不必计算，Ⅲ类和Ⅳ类场地上建筑及7度至9度设防的建筑应按本地区设防烈度计算",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},928513,"位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地面以上有10层，总高40m，结构形式为钢筋混凝土框架结构。剖面和平面如图所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共12500kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共13050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为0.9s。该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构。 1.结构的总竖向地震作用标准值FEvk最接近于（ ）kN。",[434,436,438,440],{"key":20,"text":435,"correct":22},"21060",{"key":24,"text":437,"correct":26},"21224",{"key":28,"text":439,"correct":22},"22862",{"key":31,"text":441,"correct":22},"23868",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":20,"analysis":33},928514,"位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地面以上有10层，总高40m，结构形式为钢筋混凝土框架结构。剖面和平面如图所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共12500kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共13050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为0.9s。该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构。 2.第8层的竖向地震作用标准值Fv8k最接近于（ ）kN。",[446,448,450,452],{"key":20,"text":447,"correct":26},"3065",{"key":24,"text":449,"correct":22},"3303",{"key":28,"text":451,"correct":22},"3751",{"key":31,"text":453,"correct":22},"3985",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":31,"analysis":33},928515,"位于9度抗震设防区、设计基本地震加速度值为0.40g，设计地震分组为第一组，建筑场地属Ⅱ类的办公大楼，地面以上有10层，总高40m，结构形式为钢筋混凝土框架结构。剖面和平面如图所示。该楼层顶为上人屋面。通过计算，已知每层楼面的永久荷载标准值共12500kN，每层楼面的活荷载标准值共2100kN；屋面的永久荷载标准值共13050kN，屋面的活荷载标准值共2100kN。经动力分析，考虑了填充墙的刚度后的结构基本自振周期T1为0.9s。该楼的结构布置、侧向刚度及质量等均对称、规则、均匀、属规则结构。 3.底层中柱A的竖向地震产生的轴向力标准值NEvk最接近于（ ）kN。",[458,460,462,464],{"key":20,"text":459,"correct":22},"702",{"key":24,"text":461,"correct":22},"707",{"key":28,"text":463,"correct":22},"1053",{"key":31,"text":465,"correct":26},"1061",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":24,"analysis":33},928516,"10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 1.未考虑非结构构件刚度影响时的结构基本自振周期T1（s），最接近于（ ）项数值。",[470,472,474,476],{"key":20,"text":471,"correct":22},"0.5",{"key":24,"text":473,"correct":26},"0.9",{"key":28,"text":475,"correct":22},"1.2",{"key":31,"text":477,"correct":22},"1.7",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},928517,"10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 2.若结构自振周期T1=0.68s，则T1相对应的地震影响系数α1与（ ）项数值最为接近。",[482,484,486,488],{"key":20,"text":483,"correct":22},"0.077",{"key":24,"text":485,"correct":26},"0.088",{"key":28,"text":487,"correct":22},"0.112",{"key":31,"text":489,"correct":22},"0.16",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":20,"analysis":33},928518,"10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 3.假定结构自振周期为T1=0.793s，结构底部由水平地震作用产生的总弯矩标准值M0（kN·m）与（ ）项数值最为接近。",[494,496,498,500],{"key":20,"text":495,"correct":26},"137981",{"key":24,"text":497,"correct":22},"154368",{"key":28,"text":499,"correct":22},"194018",{"key":31,"text":501,"correct":22},"202112",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":28,"analysis":33},928519,"某11层住宅，采用钢框架结构，其结构质量及刚度沿高度分布基本均匀，各层层高如图所示。抗震设防烈度为7度。 1.假定水平地震影响系数α1=0.22；屋面恒荷载标准值为4300kN，等效活荷载标准值为480kN，雪荷载标准值为160kN；各层楼盖处恒荷载标准值为4100kN，等效活荷载标准值为550kN。试问，结构总水平地震作用标准值FEk（kN），与下列（ ）项数值最为接近。 提示：按《高层民用建筑钢结构技术规程》（JGJ 99—98）底部剪力法计算。",[506,508,510,512],{"key":20,"text":507,"correct":22},"8317",{"key":24,"text":509,"correct":22},"8398",{"key":28,"text":511,"correct":26},"8471",{"key":31,"text":513,"correct":22},"8499",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":20,"analysis":33},928520,"某11层住宅，采用钢框架结构，其结构质量及刚度沿高度分布基本均匀，各层层高如图所示。抗震设防烈度为7度。 {图} 2.假定屋盖和楼盖处重力荷载代表值均为 G，与结构总水平地震作用等效的底部剪力标准值FEk=10000kN，基本自振周期T1=1.1s。试问，顶层总水平地震作用标准值F11Ek（kN），与下列（ ）项数值最为接近。",[518,520,521,523],{"key":20,"text":519,"correct":26},"3000",{"key":24,"text":269,"correct":22},{"key":28,"text":522,"correct":22},"1600",{"key":31,"text":524,"correct":22},"1400",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":20,"analysis":33},928521,"某11层住宅，采用钢框架结构，其结构质量及刚度沿高度分布基本均匀，各层层高如图所示。抗震设防烈度为7度。 3.假定框架钢材采用Q345，fv=345N\u002Fmm2，某梁柱节点构造如图所示。试问，柱在节点域的腹板最小厚度twc（mm），与下列（ ）项数值最为接近。 提示：按《高层民用建筑钢结构技术规程》（JGJ 99—98）计算。",[529,531,533,535],{"key":20,"text":530,"correct":26},"10",{"key":24,"text":532,"correct":22},"13",{"key":28,"text":534,"correct":22},"15",{"key":31,"text":536,"correct":22},"17",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":31,"analysis":33},928522,"一客车停车库的楼面结构平面如图所示，该结构采用单向板及主次梁结构，次梁的间距为4m，主梁（框架梁）的间距沿纵向为9m，沿横向为8m。次梁将楼面永久荷载及楼面活荷载以集中荷载传递给主梁见图6-21（b），当按《建筑结构荷载规范》（GB 50009—2012）规定考虑楼面活荷载折减系数时，则可算得次梁传给主梁的活荷载集中荷载标准值Pqk＝（ ）kN。",[541,543,545,547],{"key":20,"text":542,"correct":22},"144",{"key":24,"text":544,"correct":22},"120",{"key":28,"text":546,"correct":22},"90",{"key":31,"text":548,"correct":26},"86.4",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":28,"analysis":33},928523,"某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40 5.假定，该建筑所在地区的基本风压为0.40kN／m2（50年一遇），地面粗糙度为B类，风向如图所示，风载沿房屋高度方向呈倒三角形分布，地面处（±0.000）为0，屋顶高度处风振系数为1.42，L形剪力墙厚度均为300mm。试问，承载力设计时，在图示风向风荷载标准值作用下，在（±0.000）处产生的倾覆力矩标准值Mwk(kN·m)与下列何项数值最为接近？（ ） 提示：①按《高层建筑混凝土结构技术规程》（JGJ 3—2010）计算风荷载体型系数； ②假定风作用面宽度为24.3m。",[553,555,557,559],{"key":20,"text":554,"correct":22},"42000",{"key":24,"text":556,"correct":22},"47000",{"key":28,"text":558,"correct":26},"52000",{"key":31,"text":560,"correct":22},"68000",{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":24,"analysis":33},928524,"某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40 4.地上第3层某L形剪力墙墙肢的截面如图所示，墙肢轴压比为0.24。试问，该剪力墙转角处边缘构件（图中阴影部分）的纵向钢筋面积 最小取下列何项数值时才能满足规范、规程的最低构造要求？（ ） 提示：不考虑承载力计算要求。",[565,567,569,571],{"key":20,"text":566,"correct":22},"2700",{"key":24,"text":568,"correct":26},"3300",{"key":28,"text":570,"correct":22},"3500",{"key":31,"text":572,"correct":22},"3800",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},928525,"对于底部大空间剪力墙结构的转换层楼面，下列符合规定的是（ ）。",[577,579,581,583],{"key":20,"text":578,"correct":26},"应采用现浇楼板，其混凝土强度等级不应低于C30，并应双层双向配筋，且每层每向的配筋率不宜小于0.25%",{"key":24,"text":580,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于C25，并应双层双向配筋，且每层每向的配筋率不宜小于0.25%",{"key":28,"text":582,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于C30，并应双层双向配筋，且每层每向的配筋率不宜小于0.20%",{"key":31,"text":584,"correct":22},"应采用现浇楼板，其混凝土强度等级不应低于C25，并应双层双向配筋，且每层每向的配筋率不宜小于0.20%",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":31,"analysis":33},928526,"某10层钢筋混凝土框架结构，如图所示，质量和刚度沿竖向分布比较均匀，抗震设防类别为标准设防类，抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，场地类别Ⅱ类。[2014年真题] 2.假定，该框架结构进行方案调整后，结构的基本自振周期T1=1.10s，总水平地震作用标准值FEk=3750kN。试问，作用于该结构顶部附加水平地震作用△F10（kN），与下列何项数值最为接近？（ ）",[589,591,593,595],{"key":20,"text":590,"correct":22},"210",{"key":24,"text":592,"correct":22},"260",{"key":28,"text":594,"correct":22},"370",{"key":31,"text":596,"correct":26},"590",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":24,"analysis":33},928527,"某10层钢筋混凝土框架结构，如图所示，质量和刚度沿竖向分布比较均匀，抗震设防类别为标准设防类，抗震设防烈度7度，设计基本地震加速度0.10g，设计地震分组第一组，场地类别Ⅱ类。[2014年真题] 3.假定，该结构楼层屈服强度系数沿高度分布均匀，底层屈服强度系数为0.45，且不小于上层该系数的0.8，底层柱的轴压比为0.60。试问，在罕遇地震作用下按弹性分析的层间位移（mm），最大不超过下列何值时，才能满足结构弹塑性水平位移限值要求？（ ） 提示：不考虑重力二阶效应；可考虑柱子箍筋构造措施的提高。",[601,603,605,607],{"key":20,"text":602,"correct":22},"46",{"key":24,"text":604,"correct":26},"56",{"key":28,"text":606,"correct":22},"66",{"key":31,"text":608,"correct":22},"76",[610,613,616,619,622,625],{"id":15,"name":611,"category":7,"favorite":612},"领导干部任职前廉政法规知识测试题",92,{"id":614,"name":615,"category":7,"favorite":15},595,"建筑结构与设备",{"id":617,"name":618,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":620,"name":621,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":623,"name":624,"category":7,"favorite":8},534,"BIM工程师",{"id":626,"name":624,"category":7,"favorite":8},535]