[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-599-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":612},{"id":5,"name":6,"category":7,"favorite":8},599,"(结构) 专业考试二级","建筑工程",0,13,50,724,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,189,201,213,225,237,249,261,273,285,293,305,317,329,340,352,364,376,387,399,411,423,435,445,457,469,481,492,504,516,528,540,552,564,576,588,600],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},928428,1,"单选题","某地上16层、地下1层的现浇钢筋混凝土框架-剪力墙办公楼，如图所示。房屋高度为64.2m，该建筑地下室至地上第3层的层高均为4.5m，其余各层层高均为3.9m，质量和刚度沿高度分布比较均匀，丙类建筑，抗震设防烈度为7度，设计基本地震加速度为0.15g，设计地震分组为第一组，Ⅲ类场地，在规定的水平力作用下，结构底层框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的10％但不大于50％，地下1层顶板为上部结构的嵌固端。构件混凝土强度等级均为C40",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","1900",false,{"key":24,"text":25,"correct":22},"B","2100",{"key":27,"text":28,"correct":29},"C","2500",true,{"key":31,"text":32,"correct":22},"D","2800","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},928429,"下列关于高层建筑混凝土结构的抗震性能优化设计的4种观点： Ⅰ．达到A级性能目标的结构在大震作用下仍处于基本弹性状态； Ⅱ．建筑结构抗震性能化设计的性能目标，应不低于《建筑抗震设计规范》（GB 50011—2010）规定的基本设防目标； Ⅲ．严重不规则的建筑结构，其结构抗震性能目标应为A级； Ⅳ．结构抗震性能目标应综合考虑抗震设防类别、设防烈度、场地条件、结构的特殊性、建造费用、震后损失和修复难易程度等各项因素选定。 试问，针对上述观点正确性的判断，下列何项正确？（ ）[2012年真题]",[38,40,42,44],{"key":20,"text":39,"correct":22},"Ⅰ、Ⅱ、Ⅲ正确，Ⅳ错误",{"key":24,"text":41,"correct":22},"Ⅱ、Ⅲ、Ⅳ正确，Ⅰ错误",{"key":27,"text":43,"correct":29},"Ⅰ、Ⅱ、Ⅳ正确，Ⅲ错误",{"key":31,"text":45,"correct":22},"Ⅰ、Ⅲ、Ⅳ正确，Ⅱ错误",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},928430,"某16层办公楼采用钢筋混凝土框架-剪力墙结构体系，层高均为4米，平面对称，结构布置均匀规则，质量和侧向刚度沿高度分布均匀，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第二组，建筑场地类别为Ⅲ类。考虑折减后的结构自振周期为 各楼层的重力荷载代表 结构的第一振型如图所示。采用振型分解反应谱法计算地震作用。[2012年真题] 提示： 1.试问，第一振型时的基底剪力标准值V10(kN)最接近下列何项数值？（ ）",[50,52,54,56],{"key":20,"text":51,"correct":22},"10000",{"key":24,"text":53,"correct":29},"13000",{"key":27,"text":55,"correct":22},"14000",{"key":31,"text":57,"correct":22},"15000",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},928431,"某16层办公楼采用钢筋混凝土框架-剪力墙结构体系，层高均为4米，平面对称，结构布置均匀规则，质量和侧向刚度沿高度分布均匀，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第二组，建筑场地类别为Ⅲ类。考虑折减后的结构自振周期为 各楼层的重力荷载代表 结构的第一振型如图所示。采用振型分解反应谱法计算地震作用。[2012年真题] 提示： 2.假定，第一振型时地震影响系数为0.09，振型参与系数为1.5。试问，第一振型时的基底弯矩标准值(kN·m)最接近下列何项数值？（ ）",[62,64,66,68],{"key":20,"text":63,"correct":29},"685000",{"key":24,"text":65,"correct":22},"587000",{"key":27,"text":67,"correct":22},"485000",{"key":31,"text":69,"correct":22},"400000",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},928432,"某16层办公楼采用钢筋混凝土框架-剪力墙结构体系，层高均为4米，平面对称，结构布置均匀规则，质量和侧向刚度沿高度分布均匀，抗震设防烈度为8度，设计基本地震加速度为0.2g，设计地震分组为第二组，建筑场地类别为Ⅲ类。考虑折减后的结构自振周期为 各楼层的重力荷载代表 结构的第一振型如图所示。采用振型分解反应谱法计算地震作用。[2012年真题] 提示： 3.假定，横向水平地震作用计算时，该结构前三个振型基底剪力标准值分别为 相邻振型的周期比小于0.85。试问，横向对应于水平地震作用标准值的结构底层总剪力 最接近下列何项数值？（ ） 提示：结构不进行扭转耦联计算且仅考虑前三个振型地震作用。",[74,76,78,80],{"key":20,"text":75,"correct":29},"13200",{"key":24,"text":77,"correct":22},"14200",{"key":27,"text":79,"correct":22},"14800",{"key":31,"text":81,"correct":22},"15100",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},928433,"图所示的框架为某框架—剪力墙结构中的一榀边框架，其抗震等级为二级，底部一、二层顶梁截面高度为700mm，梁顶与板顶平，柱截面为700mm×700mm。已知在重力荷载和地震作用下，柱BC的轴压比为0.75，节点B和柱BC未按“强柱弱梁”调整的组合弯矩设计值(kN·m)如图所示。[2012年真题] 提示：①对应于地震作用标准值，各层框架承担的剪力均不小于结构总剪力的20％； ②按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。 1.试问，底层柱BC的纵向配筋计算时，考虑地震组合的弯矩设计值(kN·m)与下列何项数值最为接近？（ ）",[86,88,90,92],{"key":20,"text":87,"correct":22},"450",{"key":24,"text":89,"correct":29},"470",{"key":27,"text":91,"correct":22},"680",{"key":31,"text":93,"correct":22},"700",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},928434,"图所示的框架为某框架—剪力墙结构中的一榀边框架，其抗震等级为二级，底部一、二层顶梁截面高度为700mm，梁顶与板顶平，柱截面为700mm×700mm。已知在重力荷载和地震作用下，柱BC的轴压比为0.75，节点B和柱BC未按“强柱弱梁”调整的组合弯矩设计值(kN·m)如图所示。[2012年真题] 提示：①对应于地震作用标准值，各层框架承担的剪力均不小于结构总剪力的20％； ②按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。 2.假定，角柱AD在重力荷载和地震作用组合下，柱上、下端按“强柱弱梁”要求调整后的弯矩设计值分别为 （同为顺时针方向）。试问，抗震设计时柱AD端部截面的剪力设计值（kN）与下列何项数值最为接近？（ ）",[98,100,102,104],{"key":20,"text":99,"correct":22},"175",{"key":24,"text":101,"correct":29},"200",{"key":27,"text":103,"correct":22},"225",{"key":31,"text":105,"correct":22},"250",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},928435,"某现浇钢筋混凝土框架—剪力墙办公楼，地上11层，每层层高均为3.6m，房屋高度为39.9m，抗震设防烈度为9度，设计基本加速度为0.4g，设计地震分组为第一组，Ⅱ类场地，丙类建筑。若各楼面恒载标准均为12000kN，各楼层等效活载标准值均为1800kN，屋面层恒载标准值为16000kN，屋面活载标准值为1300kN，屋面雪载标准值为1000kN，结构基本自振周期T1=0.9s（已考虑非承重墙体的影响）。试问，结构总竖向地震作用标准值 与下列何项数值最接近？（ ）[2012年真题]",[110,112,114,116],{"key":20,"text":111,"correct":22},"22500",{"key":24,"text":113,"correct":29},"22700",{"key":27,"text":115,"correct":22},"25400",{"key":31,"text":117,"correct":22},"25700",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":27,"analysis":33},928436,"以下关于高层建筑混凝土结构设计与施工的4种观点： Ⅰ．分段搭设的悬挑脚手架，每段高度不得超过25m Ⅱ．大体积混凝土浇筑体的里表温差不宜大于25℃，混凝土浇筑表面与大气温差不宜大于20℃ Ⅲ．混合结构核心筒应先于钢框架或型钢混凝土框架施工，高差宜控制在4～8层，并应满足施工工序的穿插要求 Ⅳ．常温施工时，柱、墙体拆模混凝土强度不应低于1.2MPa 试问，针对上述观点是否符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）相关要求判断，下列何项正确？（ ）[2012年真题]",[122,124,126,128],{"key":20,"text":123,"correct":22},"Ⅰ、Ⅱ符合，Ⅲ、Ⅳ不符合",{"key":24,"text":125,"correct":22},"Ⅰ、Ⅲ符合，Ⅱ、Ⅳ不符合",{"key":27,"text":127,"correct":29},"Ⅱ、Ⅲ符合，Ⅰ、Ⅳ不符合",{"key":31,"text":129,"correct":22},"Ⅲ、Ⅳ符合，Ⅰ、Ⅱ不符合",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},928437,"下列关于复杂高层建筑混凝土结构抗震设计的4种说法： Ⅰ．7度抗震设防时，地上转换结构构件可采用厚板结构； Ⅱ．7度、8度抗震设计时，层数和刚度相差悬殊的建筑不宜采用连体结构； Ⅲ．带加强层高层建筑结构在抗震设计时，仅需在加强层核心筒剪力墙处设置约束边缘构件； Ⅳ．多塔楼结构在抗震设计时，塔楼中与裙房相连的外围柱，从嵌固端至裙房屋面的高度范围内，柱纵筋的最小配筋率宜适当提高。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[134,136,138,140],{"key":20,"text":135,"correct":22},"Ⅳ正确，Ⅰ、Ⅱ、Ⅲ错误",{"key":24,"text":137,"correct":29},"Ⅱ正确，Ⅰ、Ⅲ、Ⅳ错误",{"key":27,"text":139,"correct":22},"Ⅰ正确，Ⅱ、Ⅲ、Ⅳ错误",{"key":31,"text":141,"correct":22},"Ⅰ、Ⅱ、Ⅲ、Ⅳ均错误",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},928438,"抗震设计的高层建筑混凝土结构，关于地震作用的计算，下列何项符合《高层建筑混凝土结构技术规程》（JGJ 3—2010）的要求？（ ）[2012年真题]",[146,148,150,152],{"key":20,"text":147,"correct":22},"7度抗震设计时，各种结构均不必考虑竖向地震作用",{"key":24,"text":149,"correct":22},"计算双向地震作用时，应考虑偶然偏心的影响",{"key":27,"text":151,"correct":29},"7～9度抗震设防的连体结构，应采用弹性时程分析法进行多遇地震作用下的补充分析",{"key":31,"text":153,"correct":22},"高度不超过40m以弯曲变形为主的高层建筑混凝土结构，可采用底部剪力法计算地震作用",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},928439,"某16层现浇钢筋混凝土框架-剪力墙结构，房屋高度为64m，抗震设防烈度为7度，丙类建筑，场地类别Ⅱ类。在规定的水平力作用下，结构底层剪力墙部分承受的地震倾覆力矩为结构总地震倾覆力矩的92％。下列关于框架、剪力墙抗震等级的确定何项正确？（ ）[2012年真题]",[158,160,162,164],{"key":20,"text":159,"correct":22},"框架三级、剪力墙三级",{"key":24,"text":161,"correct":22},"框架二级、剪力墙二级",{"key":27,"text":163,"correct":22},"框架三级、剪力墙二级",{"key":31,"text":165,"correct":29},"框架二级、剪力墙三级",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},928440,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 1.已知该建筑物位于城市郊区，地面粗糙度为B类，所在地区基本风压W0=0.65kN\u002Fm2，屋顶处的风振系数βz=1.402。试问，在图6-16所示方向的风荷载作用下，屋顶lm高度范围内Y向的风荷载标准值Wk（kN\u002Fm2），与下列何项数值最为接近？（ ） 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。",[170,172,174,176],{"key":20,"text":171,"correct":22},"1.28",{"key":24,"text":173,"correct":29},"1.70",{"key":27,"text":175,"correct":22},"1.91",{"key":31,"text":177,"correct":22},"3.43",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},928441,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题]",[182,183,185,187],{"key":20,"text":33,"correct":22},{"key":24,"text":184,"correct":29},"2.假定，该建筑物拟作为综合楼使用，二～五层为商场，六～七层为库房，其余楼层作为办公用房。设计时其楼屋面活荷载均按等效均布荷载计算而得，各层荷载标准值如下：①屋面：永久荷载8.8kN\u002Fm2，活荷载2.0kN\u002Fm2，雪荷载0.5kN\u002Fm2；②8～15层：永久荷载8.0kN\u002Fm2，活荷载2.0kN\u002Fm2；③6～7层：永久荷载8.0kN\u002Fm2，活荷载5.0kN\u002Fm2；④2～5层：永久荷载8.0kN\u002Fm2，活荷载3.5kN\u002Fm2。试问，进行地震作用计算时，该结构的总重力荷载代表值GE（kN）应与下列何项数值最为接近？（ ）",{"key":27,"text":186,"correct":22},"提示：1．按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。2．每层面积均按850m2计算，且不考虑楼板开洞影响。",{"key":31,"text":188,"correct":22},"{图2}",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":33},928442,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 3.假定，该结构对应于x向地震作用标准值的底部总剪力V0=4250kN，相应未经调整的各层框架部分所承担的地震总剪力中的最大值为620kN。试问，抗震设计时，x向地震作用下，相应的底层框架部分承担的地震总剪力（kN）为下列何项数值时符合有关规范、规程的最低要求？（ ）",[193,195,197,199],{"key":20,"text":194,"correct":22},"620",{"key":24,"text":196,"correct":29},"850",{"key":27,"text":198,"correct":22},"900",{"key":31,"text":200,"correct":22},"930",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":33},928443,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 4.假定，该结构位于非地震区，仅考虑风荷载作用，且水平风荷载沿竖向呈倒三角形分布，其最大荷载标准值q=65kN\u002Fm，已知该结构各层重力荷载设计值总和为 试问，在上述水平风力作用下，该结构顶点质心的弹性水平位移u（mm）不超过下列何项数值时，方可不考虑重力二阶效应的影响？（ ）",[205,207,209,211],{"key":20,"text":206,"correct":22},"40",{"key":24,"text":208,"correct":29},"50",{"key":27,"text":210,"correct":22},"60",{"key":31,"text":212,"correct":22},"70",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":20,"analysis":33},928444,"某15层框架一剪力墙结构，其平立面示意如图所示，质量和刚度沿竖向分布均匀，对风荷载不敏感，房屋高度58m，首层层高5m，二～五层层高4.5m，其余各层层高均为3.5m，所在地区抗震设防烈度为7度，设计基本地震加速度为0.159，Ⅲ类场地，设计地震分组为第一组。[2011年真题] 5.假定，在规定的水平作用下，该结构底层框架部分承受的地震倾覆力矩为结构总地震倾覆力矩的60％，已知底层某框架柱截面为800mm×800mm，剪跨比大于2，混凝土强度等级C40（fn=19.1N\u002Fmm2），在不采用有利于提高轴压比限值的构造措施的条件下。试问，满足规范轴压比限值要求时，该柱考虑地震作用组合的轴压力设计值（kN）最大值，与下列何项数值最为接近？（ ） 提示：按《建筑抗震设计规范》（GB 50011—2010）作答。",[217,219,221,223],{"key":20,"text":218,"correct":29},"7950",{"key":24,"text":220,"correct":22},"8560",{"key":27,"text":222,"correct":22},"9170",{"key":31,"text":224,"correct":22},"11000",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":31,"analysis":33},928445,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 3.假定，框架梁CD截面尺寸为250mm×650mm，h0=590mm，根据抗震计算结果，其边支座柱边的梁端截面顶面配筋为6Φ25。试问，在满足抗震构造要求的条件下其底部最小配筋面积（mm2）与下列何项数值最为接近？（ ）",[229,231,233,235],{"key":20,"text":230,"correct":22},"645",{"key":24,"text":232,"correct":22},"884",{"key":27,"text":234,"correct":22},"893",{"key":31,"text":236,"correct":29},"1473",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":31,"analysis":33},928446,"某8层办公楼，采用现浇钢筋混凝土框架结构，如图所示。抗震设防烈度为8度，设计地震加速度0.20g，设计地震分组为第一组，该房屋属丙类建筑，建于Ⅱ类场地，设有两层地下室，地下室顶板可作为上部结构的嵌固部位，室内外高差450mm。梁柱的混凝土强度等级均为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），钢筋采用HRB335钢（fy=300N\u002Fmm2），质量和刚度沿竖向分布均匀。[2011年真题] 4.已知首层框架角柱EF截面尺寸为500mm×600mm，与其相连的首层顶边跨梁截面为250mm×650mm，假定该框架抗震等级为一级，该柱顺时针方向的组合弯矩设计值为：柱",[241,243,245,247],{"key":20,"text":242,"correct":22},"380",{"key":24,"text":244,"correct":22},"405",{"key":27,"text":246,"correct":22},"415",{"key":31,"text":248,"correct":29},"445",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":24,"analysis":33},928447,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 1.假定，首层墙肢1的抗震等级为二级，考虑地震组合的一组不利内力计算值Mw=360kN·m，Vw=185kN。试问，在满足规范剪力墙截面受剪承载力限值时，墙肢l底部截面组合的剪力设计值（kN）与下列何项数值最为接近？（ ） 提示：1．按《建筑抗震设计规范》（GB 50011—2010）作答；2．取hw0=hw计算。",[253,255,257,259],{"key":20,"text":254,"correct":22},"1400",{"key":24,"text":256,"correct":29},"1540",{"key":27,"text":258,"correct":22},"1840",{"key":31,"text":260,"correct":22},"2060",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":27,"analysis":33},928448,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 2.墙肢1处在第三层时，计算表明其端部所设暗柱仅需按构造配筋，轴压比=0.5。试问，该墙肢端部暗柱的竖向钢筋最小配置数量应为下列何项时，才能满足规范、规程的最低抗震构造要求？（ ） 提示：按《高层建筑混凝土结构技术规程》（JGJ 3—2010）作答。",[265,267,269,271],{"key":20,"text":266,"correct":22},"6Φ20",{"key":24,"text":268,"correct":22},"6Φ18",{"key":27,"text":270,"correct":29},"6Φ16",{"key":31,"text":272,"correct":22},"6Φ14",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":27,"analysis":33},928449,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 3.已知首层墙肢2一端边缘构件截面配筋形式如图6-19所示，假定其抗震等级为一级，轴压比等于0.4，箍筋采用HRB335级钢筋（fy=300N\u002Fmm2），箍筋保护层厚度取10mm。试问，其边缘构件箍筋采用下列何项配置时方能满足规范、规程的最低构造要求？（ ）提示：1．按《建筑抗震设计规范》（GB 50011—2010）作答；2．不计入墙水平分布筋；3．假定不计入箍筋重叠部分。",[277,279,281,283],{"key":20,"text":278,"correct":22},"Φ8@100",{"key":24,"text":280,"correct":22},"Φ10@150",{"key":27,"text":282,"correct":29},"Φ10@100",{"key":31,"text":284,"correct":22},"Φ12@100",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":31,"analysis":33},928450,"某高层住宅楼（丙类建筑），设有两层地下室，地面以上为16层，房屋高度45.60m，室内外高差0.30m，首层层高3.3m，标准层层高为2.8m。建于8度地震区（设计基本地震加速为0.2g，设计地震分组为第一组，Ⅱ类建筑场地）。采用短肢剪力墙较多的剪力墙结构，l～3层墙体厚度均为250mm，地上其余层墙体厚度均为200mm，在规定水平地震作用下其短肢剪力墙承担的第一振型底部地震倾覆力矩占结构底部总地震倾覆力矩的45％。其中一榀剪力墙一至三层截面如图所示。墙体混凝土强度等级7层楼板面以下为C35（fc=16.7N\u002Fmm2，ft=1.57N\u002Fmm2），7层以上为C30，墙体竖向、水平分布钢筋以及墙肢边缘构件的箍筋均采用HRB335级钢筋，墙肢边缘构件的纵向受力钢筋采用HRB400级钢筋。[2011年真题] 4.已知二层某连梁截面尺寸为250mm×600mm，ln=1100mm，抗震等级为二级，as=as’=35mm，箍筋采用HRB335级钢筋（fy=300N\u002Fmm2），连梁左、右端同时针方向考虑地震作用组合的弯矩设计值 重力荷载代表值作用下，按简支梁计算的连梁端截面剪力设计值Vgh=10kN。试问，该连梁满足《高层建筑混凝土结构技术规程》（JGJ 3—2010）抗震设计要求的最小箍筋配置（双肢箍）应取下列何项？（ ）",[289,290,291,292],{"key":20,"text":278,"correct":22},{"key":24,"text":282,"correct":22},{"key":27,"text":280,"correct":22},{"key":31,"text":284,"correct":29},{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":31,"analysis":33},928451,"下列关于竖向地震作用的主张，其中何项不正确？（ ）[2011年真题]",[297,299,301,303],{"key":20,"text":298,"correct":22},"9度抗震设计的高层建筑应计算竖向地震作用",{"key":24,"text":300,"correct":22},"8度抗震设计时，跨度大于24m的结构应考虑竖向地震作用",{"key":27,"text":302,"correct":22},"8度抗震设计的带转换层高层结构中的转换构件应考虑竖向地震作用的影响",{"key":31,"text":304,"correct":29},"8度采用隔震设计的建筑结构，可不计竖向地震作用",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":27,"analysis":33},928452,"下列关于高层建筑钢筋混凝土结构有关抗震的一些观点，其中何项不正确？（ ）[2011年真题] 提示：不考虑楼板开洞影响，按《建筑抗震设计规范》（GB 50011—2010）作答。",[309,311,313,315],{"key":20,"text":310,"correct":22},"对于板柱—抗震墙结构，沿两个主轴方向穿过柱截面的板底两个方向钢筋的受拉承载力应满足该层楼板重力荷载代表值（8度时尚宜计入竖向地震）作用下的柱轴压力设计值",{"key":24,"text":312,"correct":22},"钢筋混凝土框架—剪力墙结构中的剪力墙两端（不包括洞口两侧）宜设置端柱或与另一方向的剪力墙相连",{"key":27,"text":314,"correct":29},"抗震设计的剪力墙应设置底部加强部位，当结构计算嵌固端位于地下一层底板时，底部加强部位的高度应从地下一层底板算起",{"key":31,"text":316,"correct":22},"钢筋混凝土结构地下室顶板作为上部结构的嵌固部位时，应避免在地下室顶板开大洞口。地下室顶板的厚度不宜小于180mm，若柱网内设置多个次梁时，可适当减小",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":20,"analysis":33},928453,"某单层工业厂房，厂房柱距12m，采用工字形截面的实腹式钢吊车梁。设置有两台Q＝25\u002F10t的软钩桥式吊车，吊车每侧有两个车轮，轮距4m，最大轮压标准值Pkmax＝279.7kN，横行小车质量标准值Q1＝73.5kN，吊车轨道高度hR＝130mm。 1.当吊车为中级工作制时，作用在每个车轮处的横向水平荷载标准值最接近于（ ）kN。",[321,323,325,327],{"key":20,"text":322,"correct":29},"8.0",{"key":24,"text":324,"correct":22},"11.1",{"key":27,"text":326,"correct":22},"15.9",{"key":31,"text":328,"correct":22},"22.2",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":27,"analysis":33},928454,"某单层工业厂房，厂房柱距12m，采用工字形截面的实腹式钢吊车梁。设置有两台Q＝25\u002F10t的软钩桥式吊车，吊车每侧有两个车轮，轮距4m，最大轮压标准值Pkmax＝279.7kN，横行小车质量标准值Q1＝73.5kN，吊车轨道高度hR＝130mm。 2.假定吊车为重级工作制时，作用在每个车轮处的横向水平荷载标准值最接近于（ ）kN。",[333,334,336,338],{"key":20,"text":322,"correct":22},{"key":24,"text":335,"correct":22},"14.0",{"key":27,"text":337,"correct":29},"28.0",{"key":31,"text":339,"correct":22},"42.0",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":27,"analysis":33},928455,"黑龙江省佳木斯西北方向某县的一多层建筑在设计时，《建筑结构荷载规范》（GB 50009—2012）附录E中没有给出该县的基本雪压，但当地气象部门给出年最大积雪深度为0.50m，由此设计单位可按《建筑结构荷载规范》（GB 50009—2012）附录E第 E.1.2条规定确定雪压值s＝（ ）kN\u002Fm2。",[344,346,348,350],{"key":20,"text":345,"correct":22},"0.50",{"key":24,"text":347,"correct":22},"0.60",{"key":27,"text":349,"correct":29},"0.74",{"key":31,"text":351,"correct":22},"0.80",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":31,"analysis":33},928456,"一幢8层的钢筋混凝土框架结构，在设防烈度8度（0.2g）多遇地震的水平地震作用下的水平位移如图所示。其顶层的弹性水平位移δ8=60mm，第7层的水平位移δ7=54mm。 1.计算得顶层的弹性层间位移θe,8=（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"1\u002F400",{"key":24,"text":359,"correct":22},"1\u002F500",{"key":27,"text":361,"correct":22},"1\u002F600",{"key":31,"text":363,"correct":29},"1\u002F667",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":20,"analysis":33},928457,"一幢8层的钢筋混凝土框架结构，在设防烈度8度（0.2g）多遇地震的水平地震作用下的水平位移如图所示。其顶层的弹性水平位移δ8=60mm，第7层的水平位移δ7=54mm。 2.由（1）已算得多遇地震作用下的第8层弹性层间位移，现已知第8层的楼层屈服强度系数ξy=0.4（楼层屈服强度系数为按构件实际配筋和材料强度标准值计算的楼层受剪承载力和按罕遇地震作用标准值计算的弹性地震剪力的比值）。由此可算得该框架结构在第8层的弹塑性层间位移角θP,8=（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":29},"1\u002F333",{"key":24,"text":371,"correct":22},"1\u002F220",{"key":27,"text":373,"correct":22},"1\u002F200",{"key":31,"text":375,"correct":22},"1\u002F150",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":24,"analysis":33},928458,"一商厦建筑的抗震设防烈度为8度（0.30g）。该建筑的入口处采用悬挑长度为17.5m的钢桁架（见图），桁架高度为2.5m。钢桁架节点上的重力荷载代表值Pgk=90kN。由此，可算得该桁架端部斜腹杆a仅由竖向地震作用产生的轴向力 =（ ）kN。",[380,381,383,385],{"key":20,"text":208,"correct":22},{"key":24,"text":382,"correct":29},"76.4",{"key":27,"text":384,"correct":22},"80",{"key":31,"text":386,"correct":22},"100",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":20,"analysis":33},928459,"一商店建筑中有一挑出长度为8m的长悬挑梁，梁上作用着永久荷载标准值的线荷载gk=30kN\u002Fm，楼面活荷载标准值的线荷载qk=20kN\u002Fm（见图）。该建筑的抗震设防烈度为8度（0.30g）。由此可算得梁端A处的最大弯矩设计值MA=（ ）kN·m。 提示：计算时应对有无竖向地震作用，以及比较永久荷载效应控制的组合与可变荷载效应控制的组合，然后确定最大弯矩设计值MA。",[391,393,395,397],{"key":20,"text":392,"correct":29},"2048.0",{"key":24,"text":394,"correct":22},"1923.2",{"key":27,"text":396,"correct":22},"1800.0",{"key":31,"text":398,"correct":22},"1785.6",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":31,"analysis":33},928460,"一展览厅的圆弧形静定三铰拱，其跨度l=25m，矢高f=4m（见图），在 C、 D、E处均作用着两个集中荷载Pgk及Pqk，即一是由永久荷载标准值产生的拱顶集中荷载Pgk=100kN，另一是由拱面活荷载标准值产生的拱顶集中荷载Pqk=50kN，由此算得该拱底部拉杆的轴向拉力设计值NA=（ ）kN。",[403,405,407,409],{"key":20,"text":404,"correct":22},"495.8",{"key":24,"text":406,"correct":22},"560.55",{"key":27,"text":408,"correct":22},"585.25",{"key":31,"text":410,"correct":29},"593.75",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":27,"analysis":33},928461,"一钢筋混凝土排架，由于三种荷载（不包括柱自重）使排架柱柱脚A处产生三个柱脚弯矩标准值，MAgk=50kN·m、MAqk=30kN·m、MAck=60kN·m（见图6-28（a）、（b）、（c）），MAgk是柱顶处屋面桁架上永久荷载的偏心反力产生的，MAqk是柱顶处屋面桁架上活荷载的偏心反力产生的，MAck是柱中部吊车梁上A5级软钩吊车荷载的偏心反力产生的。风荷载作用下产生的柱脚弯矩标准值MAwk=65kN·m（见图）。 1.由桁架上永久荷载、活荷载和吊车荷载产生的柱脚最大弯矩设计值MA应为（ ）kN·m。计算时对效应的组合不采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则。",[415,417,419,421],{"key":20,"text":416,"correct":22},"160.8",{"key":24,"text":418,"correct":22},"166",{"key":27,"text":420,"correct":29},"173.4",{"key":31,"text":422,"correct":22},"180",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":31,"analysis":33},928462,"一钢筋混凝土排架，由于三种荷载（不包括柱自重）使排架柱柱脚A处产生三个柱脚弯矩标准值，MAgk=50kN·m、MAqk=30kN·m、MAck=60kN·m（见图6-28（a）、（b）、（c）），MAgk是柱顶处屋面桁架上永久荷载的偏心反力产生的，MAqk是柱顶处屋面桁架上活荷载的偏心反力产生的，MAck是柱中部吊车梁上A5级软钩吊车荷载的偏心反力产生的。风荷载作用下产生的柱脚弯矩标准值MAwk=65kN·m（见图）。 2.还需考虑风荷载作用下产生的柱脚弯矩。由桁架上永久荷载和三种可变荷载确定的柱脚最大弯矩设计值MA应为（ ）kN·m。计算时对效应的组合不采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则。",[427,429,431,433],{"key":20,"text":428,"correct":22},"215.4",{"key":24,"text":430,"correct":22},"228",{"key":27,"text":432,"correct":22},"230",{"key":31,"text":434,"correct":29},"239.2",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":33},928463,"一钢筋混凝土排架，由于三种荷载（不包括柱自重）使排架柱柱脚A处产生三个柱脚弯矩标准值，MAgk=50kN·m、MAqk=30kN·m、MAck=60kN·m（见图6-28（a）、（b）、（c）），MAgk是柱顶处屋面桁架上永久荷载的偏心反力产生的，MAqk是柱顶处屋面桁架上活荷载的偏心反力产生的，MAck是柱中部吊车梁上A5级软钩吊车荷载的偏心反力产生的。风荷载作用下产生的柱脚弯矩标准值MAwk=65kN·m（见图）。 3.采用《建筑结构荷载规范》（GB 50009—2012）第3.2.4条的简化规则，计算在四种荷载下柱脚A处的最大弯矩设计值MA应为（ ）kN·m。",[439,441,442,443],{"key":20,"text":440,"correct":29},"255.3",{"key":24,"text":434,"correct":22},{"key":27,"text":430,"correct":22},{"key":31,"text":444,"correct":22},"210.3",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":27,"analysis":33},928464,"下列四种高层建筑结构布置正确的是（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":22},"框架结构体系，当矩形建筑平面的长边边长为短边的4倍时，主要承重框架宜顺长向布置，形成纵向布置方案，对抗侧力有利",{"key":24,"text":452,"correct":22},"框架—剪力墙结构体系，当矩形建筑平面的长边边长为短边的4倍时，顺长边方向布置的纵向剪力墙宜集中布置在房屋的纵向两尽端",{"key":27,"text":454,"correct":29},"不论采用哪种结构，在一个独立结构单元内，其结构的平面布置宜对称、刚度和承载力分布均匀",{"key":31,"text":456,"correct":22},"不论场地的地质情况如何，为了高层建筑的抗滑和抗倾覆需要，均宜设地下室",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},928465,"对框架—核心筒结构进行结构布置时，下列概念不正确的是（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"核心筒是框架—核心筒结构抵抗侧向力的最主要构件，核心筒需占有一定的面积，以获得受力所需的侧向刚度",{"key":24,"text":464,"correct":22},"为了尽可能地减少扭矩，宜布置核心筒位于整个结构的中央，筒外形对称，甚至筒内墙肢也宜均匀、对称设置，以适应框架—核心筒结构对扭矩较敏感的特点",{"key":27,"text":466,"correct":22},"为保证框架—核心筒结构的侧向刚度沿竖向不发生突变，宜将核心筒贯通建筑物的全高",{"key":31,"text":468,"correct":29},"为降低层高和方便铺设管线，同时也避免楼盖主梁搁置在核心筒的连梁上，可采用无梁楼盖将核心筒与周边柱、内柱连成整体，因此，周边柱之间的框架梁也可一并省去",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":27,"analysis":33},928466,"在选择楼盖结构设计方案时，下列各项不可取的是（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":22},"抗震设计时，不论板柱—剪力墙结构房屋有多高，顶层及地下一层的顶板，应采用现浇的肋形梁板结构",{"key":24,"text":476,"correct":22},"房屋高度超过50m时，框架—核心筒结构房屋的楼盖，应采用现浇楼盖结构，包括肋形梁板楼盖、双向密肋楼盖、压型钢板与混凝土的组合楼盖等",{"key":27,"text":478,"correct":29},"房屋高度不超过50m的部分框支剪力墙结构，其转换层也可采用装配整体式楼盖，但应有增加预制板之间的整体性一系列构造措施",{"key":31,"text":480,"correct":22},"房屋高度不超过50m的框架结构或剪力墙结构，允许采用装配式楼盖，并配以提高预制板之间的整体性措施",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":27,"analysis":33},928467,"在8度抗震区有一高21m的钢筋混凝土的框架结构裙房，与高120m的钢筋混凝土框架—剪力墙结构主楼之间，设防震缝一道。该防震缝的最小宽度δ应为（ ）mm。",[485,486,488,490],{"key":20,"text":212,"correct":22},{"key":24,"text":487,"correct":22},"77",{"key":27,"text":489,"correct":29},"140",{"key":31,"text":491,"correct":22},"539",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":33},928468,"某具有高层装配整体楼面的框架—剪力墙结构，抗震设防烈度8度，楼面横向宽度18m，在布置横向剪力墙时，下列间距符合规定的是（ ）。",[496,498,500,502],{"key":20,"text":497,"correct":29},"30m",{"key":24,"text":499,"correct":22},"40m",{"key":27,"text":501,"correct":22},"45m",{"key":31,"text":503,"correct":22},"54m",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":31,"analysis":33},928469,"一幢高60m、按6度抗震设防、位于Ⅳ类场地的钢筋混凝土框架—剪力墙结构，在基本振型地震作用下，框架部分承受的地震倾覆力矩大于结构总地震倾覆力矩的50%。在进行结构的抗震设计时，正确的是（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":22},"因6度抗震设防，可允许不进行截面的抗震验算，仅需对框架和剪力墙分别按四级和三级抗震等级考虑抗震构造措施",{"key":24,"text":511,"correct":22},"应进行截面的抗震验算，并同时对框架按四级、剪力墙按三级抗震等级考虑抗震构造措施",{"key":27,"text":513,"correct":22},"应进行截面的抗震验算，并同时对框架按三级、剪力墙按二级抗震等级考虑抗震构造措施",{"key":31,"text":515,"correct":29},"应进行截面的抗震验算，并同时对框架和剪力墙均按二级抗震等级考虑抗震构造措施",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":31,"analysis":33},928470,"在设计屋面结构时，下列说法不正确的是（ ）。",[520,522,524,526],{"key":20,"text":521,"correct":22},"根据《建筑结构荷载规范》（GB 50009—2012），不上人的屋面均布活荷载标准值0.5kN\u002Fm2中，不包括因屋面排水不畅或堵塞所引起的积水重",{"key":24,"text":523,"correct":22},"根据《建筑结构荷载规范》（GB 50009—2012），屋顶花园的均布活荷载标准值3.0kN\u002Fm2中，不包括土、石、花草等重量",{"key":27,"text":525,"correct":22},"屋面均布活荷载，不与雪荷载同时组合",{"key":31,"text":527,"correct":29},"当为斜屋面时，《建筑结构荷载规范》（GB 50009—2012）第5.3.1条，屋面均布活荷载标准值是以沿屋面斜坡面积衡量的",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":24,"analysis":33},928471,"在一展览馆的楼面上，有一静止的展品及其墩座，其自重的标准值共为30kN；墩座经厚50mm的垫层坐落在板跨为3m（单向板）、板厚为150mm的钢筋混凝土楼板上。该展品的四周无其他展品的展览区（见图）。 l——板跨；bcx、bcy——分别为平行、垂直于板跨的荷载作用面的计算宽度；b——局部分布荷载的有效分布宽度。 1.单向板上，由墩座和展品这一局部荷载在板中产生的最大弯矩Mmax最接近于（ ）kN·m。",[532,534,536,538],{"key":20,"text":533,"correct":22},"22.5",{"key":24,"text":535,"correct":29},"21.19",{"key":27,"text":537,"correct":22},"20.02",{"key":31,"text":539,"correct":22},"19.03",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":24,"analysis":33},928472,"在一展览馆的楼面上，有一静止的展品及其墩座，其自重的标准值共为30kN；墩座经厚50mm的垫层坐落在板跨为3m（单向板）、板厚为150mm的钢筋混凝土楼板上。该展品的四周无其他展品的展览区（见图）。 l——板跨；bcx、bcy——分别为平行、垂直于板跨的荷载作用面的计算宽度；b——局部分布荷载的有效分布宽度。 2.单向板上局部荷载的有效分布宽度b最接近于（ ）m。",[544,546,548,550],{"key":20,"text":545,"correct":22},"3.27",{"key":24,"text":547,"correct":29},"2.85",{"key":27,"text":549,"correct":22},"2.69",{"key":31,"text":551,"correct":22},"0.75",{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":20,"analysis":33},928473,"在一展览馆的楼面上，有一静止的展品及其墩座，其自重的标准值共为30kN；墩座经厚50mm的垫层坐落在板跨为3m（单向板）、板厚为150mm的钢筋混凝土楼板上。该展品的四周无其他展品的展览区（见图）。 l——板跨；bcx、bcy——分别为平行、垂直于板跨的荷载作用面的计算宽度；b——局部分布荷载的有效分布宽度。 3.单向板上在（b×l）面积上的等效均布荷载q最接近于（ ）kN\u002Fm2。",[556,558,560,562],{"key":20,"text":557,"correct":29},"10.11",{"key":24,"text":559,"correct":22},"6.61",{"key":27,"text":561,"correct":22},"4.8",{"key":31,"text":563,"correct":22},"3.5",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":27,"analysis":33},928474,"某城市郊区有一30层的一般钢筋混凝土高层建筑，如图所示。地面以上高度为100m，迎风面宽度为25m，按50年重现期的基本风压w0=0.60kN\u002Fm2，风荷载体型系数为1.3。 1.确定高度100m处围护结构的风荷载标准值最接近于（ ）kN\u002Fm2。",[568,570,572,574],{"key":20,"text":569,"correct":22},"1.616",{"key":24,"text":571,"correct":22},"1.945",{"key":27,"text":573,"correct":29},"2.462",{"key":31,"text":575,"correct":22},"2.505",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":31,"analysis":33},928475,"某城市郊区有一30层的一般钢筋混凝土高层建筑，如图所示。地面以上高度为100m，迎风面宽度为25m，按50年重现期的基本风压w0=0.60kN\u002Fm2，风荷载体型系数为1.3。 2.假定作用于100m高度处的风荷载标准值wk=2.1kN\u002Fm2，又已知突出屋面小塔楼风剪力标准值ΔPn=500kN及风弯矩标准值ΔMn=2000kN·m，作用于100m高度的屋面处。设风压沿高度的变化为倒三角形（地面处为0）。在地面（z=0）处，风荷载产生倾覆力矩的设计值最接近于（ ）kN·m。",[580,582,584,586],{"key":20,"text":581,"correct":22},"218760",{"key":24,"text":583,"correct":22},"233333",{"key":27,"text":585,"correct":22},"303333",{"key":31,"text":587,"correct":29},"317800",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":24,"analysis":33},928476,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 2.未考虑非结构构件刚度影响时的框架基本自振周期T1最接近于（ ）s。",[592,594,596,598],{"key":20,"text":593,"correct":22},"0.5",{"key":24,"text":595,"correct":29},"0.9",{"key":27,"text":597,"correct":22},"1.2",{"key":31,"text":599,"correct":22},"1.7",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":31,"analysis":33},928477,"一幢十层教学楼，采用全现浇钢筋混凝土框架结构体系，抗震设防烈度为8度，设计地震分组为一组、Ⅱ类场地。在重力荷载代表值作用下，中间横向框架的计算简图如图所示。 3.假定建筑物各层的重力荷载代表值如图所示，且结构基本自振周期T1=1.0s。若采用底部剪力法进行地震作用计算时，结构总水平地震作用设计值FE最接近于（ ）kN。",[604,606,608,610],{"key":20,"text":605,"correct":22},"3800",{"key":24,"text":607,"correct":22},"4400",{"key":27,"text":609,"correct":22},"4900",{"key":31,"text":611,"correct":29},"5500",[613,616,619,622,625,628],{"id":15,"name":614,"category":7,"favorite":615},"领导干部任职前廉政法规知识测试题",92,{"id":617,"name":618,"category":7,"favorite":15},595,"建筑结构与设备",{"id":620,"name":621,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":623,"name":624,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":626,"name":627,"category":7,"favorite":8},534,"BIM工程师",{"id":629,"name":627,"category":7,"favorite":8},535]