[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-599-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":590},{"id":5,"name":6,"category":7,"favorite":8},599,"(结构) 专业考试二级","建筑工程",0,1,50,724,[13,33,45,57,69,81,93,105,113,125,137,149,161,173,185,197,209,221,233,245,257,269,280,292,304,313,325,337,348,358,370,382,394,402,414,424,436,445,455,466,474,486,498,510,521,533,545,554,566,578],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},927827,"单选题","某五层中学教学楼，采用现浇钢筋混凝土框架结构，框架最大跨度9m，层高均为3.6m，抗震设防烈度7度，设计基本地震加速度0.10g，建筑场地类别Ⅱ类，设计地震分组第一组，框架混凝土强度等级C30。[2014年真题] 假定，框架的抗震等级为二级，框架底层角柱上端截面考虑地震作用并经强柱弱梁调整后组合的弯矩设计值（顺时针方向）为180kN·m，该角柱下端截面考虑地震作用组合的弯矩设计值（顺时针方向）为200kN·m，底层柱净高为3m。试问，该柱的剪力设计值V（kN）与下列何项数值最为接近？（ ） 提示：按《混凝土结构设计规范》（GB 50010—2010）作答。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","165",false,{"key":23,"text":24,"correct":21},"B","181",{"key":26,"text":27,"correct":21},"C","194",{"key":29,"text":30,"correct":31},"D","229",true,"",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":26,"analysis":32},927828,"某五层中学教学楼，采用现浇钢筋混凝土框架结构，框架最大跨度9m，层高均为3.6m，抗震设防烈度7度，设计基本地震加速度0.10g，建筑场地类别Ⅱ类，设计地震分组第一组，框架混凝土强度等级C30。[2014年真题] 假定，框架的抗震等级为二级，框架底层角柱上端截面考虑地震作用并经强柱弱梁调整后组合的弯矩设计值（顺时针方向）为180kN·m，该角柱下端截面考虑地震作用组合的弯矩设计值（顺时针方向）为200kN·m，底层柱净高为3m。试问，该柱的剪力设计值V（kN）与下列何项数值最为接近？（ ） 假定，框架某中间层中柱截面尺寸为600mm×600mm，所配箍筋为10@100／150（4），fyv=360N／mm2，考虑地震作用组合的柱轴力设计值为2000kN，该框架柱的计算剪跨比为2.7，。试问，该柱箍筋非加密区考虑地震作用组合的斜截面受剪承载力V（kN），与下列何项数值最为接近？（ ）",[37,39,41,43],{"key":19,"text":38,"correct":21},"645",{"key":23,"text":40,"correct":21},"670",{"key":26,"text":42,"correct":31},"759",{"key":29,"text":44,"correct":21},"789",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":26,"analysis":32},927829,"关于预应力混凝土构件的下列说法，何项不正确？（ ）[2014年真题]",[49,51,53,55],{"key":19,"text":50,"correct":21},"提高了构件的斜截面受剪承载力",{"key":23,"text":52,"correct":21},"有效改善了构件的正常使用极限状态性能",{"key":26,"text":54,"correct":31},"预应力混凝土的强度等级不宜低于C30",{"key":29,"text":56,"correct":21},"钢绞线的张拉控制应力取值应按其极限强度标准值计算",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":26,"analysis":32},927830,"关于混凝土叠合构件，下列表述何项不正确？（ ）[2014年真题]",[61,63,65,67],{"key":19,"text":62,"correct":21},"考虑预应力长期影响，可将计算所得的预应力混凝土叠合构件在使用阶段的预应力反拱值乘以增大系数1.75",{"key":23,"text":64,"correct":21},"叠合梁的斜截面受剪承载力计算应取叠合层和预制构件中的混凝土强度等级的较低值",{"key":26,"text":66,"correct":31},"叠合梁的正截面受弯承载力计算应取叠合层和预制构件中的混凝土强度等级的较低值",{"key":29,"text":68,"correct":21},"叠合板的叠合层混凝土厚度不应小于40mm，混凝土强度等级不宜低于C25",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":29,"analysis":32},927831,"牛腿尺寸如图2-3所示，结构安全等级为二级，柱截面宽度b=400mm，高度h=600mm，as=40mm，作用于牛腿顶部的竖向力设计值Fv=450kN，水平拉力设计值Fh=90kN，混凝土强度等级为C30，牛腿纵向受力钢筋采用HRB400，箍筋采用HPB300。试问，牛腿的配筋面积As（mm2）与下列何项数值最为接近？（ ）[2014年真题]",[73,75,77,79],{"key":19,"text":74,"correct":21},"450",{"key":23,"text":76,"correct":21},"480",{"key":26,"text":78,"correct":21},"750",{"key":29,"text":80,"correct":31},"780",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":26,"analysis":32},927832,"某现浇钢筋混凝土框架结构，抗震等级二级，混凝土强度等级C30，梁、柱均采用HRB400钢筋，柱截面尺寸为400mm×400mm，柱纵筋的保护层厚度为35mm，试问，对中间层边柱节点，当施工采取不扰动钢筋措施时，梁上部纵向钢筋满足锚固要求的最大直径（mm），不应大于下列何项数值？（ ）[2014年真题]",[85,87,89,91],{"key":19,"text":86,"correct":21},"18",{"key":23,"text":88,"correct":21},"20",{"key":26,"text":90,"correct":31},"22",{"key":29,"text":92,"correct":21},"25",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":26,"analysis":32},927833,"某叠合梁，结构安全等级为二级，叠合前截面尺寸300mm×450mm，混凝土强度等级C35，叠合后截面为300mm×600mm，叠合层的混凝土强度等级C30，配有双肢箍8@200，fyv=360N／mm2，as=40mm，试问，此叠合梁叠合面的受剪承载力设计值V（kN），与下列何项数值最为接近？（ ）[2014年真题]",[97,99,101,103],{"key":19,"text":98,"correct":21},"270",{"key":23,"text":100,"correct":21},"297",{"key":26,"text":102,"correct":31},"374",{"key":29,"text":104,"correct":21},"402",{"id":106,"libraryId":5,"type":9,"typeLabel":15,"stem":107,"options":108,"answer":23,"analysis":32},927834,"假定，钢筋混凝土矩形截面简支梁如图下，梁跨度为5.4m，截面尺寸b×h=250mm×450mm，混凝土强度等级为C30，纵筋采用HRB400钢筋，箍筋采用HPB300钢筋，该梁的跨中受拉区纵筋As=620mm2，受扭纵筋Astl=280mm2（满足受扭纵筋最小配筋率要求），受剪箍筋Asvl／s=0.112mm2／mm，受扭箍筋Astl／s=0.2mm2／mm，试问，该梁跨中截面配筋应取下图何项？（ ）[2014年真题]",[109,110,111,112],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":31},{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":114,"libraryId":5,"type":9,"typeLabel":15,"stem":115,"options":116,"answer":26,"analysis":32},927835,"某框架结构顶层端节点处框架梁截面尺寸为300mm×700mm，混凝土强度等级为C30，as=as′=60mm，纵筋采用HRB500钢筋。试问，为防止框架顶层端节点处梁上部钢筋配筋率过高而引起节点核心区混凝土的斜压破坏，框架梁上部纵向钢筋的最大配筋量（mm2）应与下列何项数值最为接近？（ ）[2013年真题]",[117,119,121,123],{"key":19,"text":118,"correct":21},"1500",{"key":23,"text":120,"correct":21},"1800",{"key":26,"text":122,"correct":31},"2200",{"key":29,"text":124,"correct":21},"2500",{"id":126,"libraryId":5,"type":9,"typeLabel":15,"stem":127,"options":128,"answer":29,"analysis":32},927836,"关于预埋件及连接件设计的下列4种说法： Ⅰ.预埋件锚筋中心至锚板边缘的距离不应小于2d和20mm（d为锚筋直径）； Ⅱ.受拉直锚筋和弯折锚筋的锚固长度不应小于35d（d为锚筋直径）； Ⅲ.直锚筋与锚板应采用T形焊接，当锚筋直径不大于20mm时宜采用压力埋弧焊； Ⅳ.当一个预制构件上设有4个吊环时，应按3个吊环进行计算，在构件的自重标准值作用下，每个吊环的钢筋应力不应大于50N／mm2。试问，以下何项是全部正确的？（ ）[2013年真题]",[129,131,133,135],{"key":19,"text":130,"correct":21},"Ⅰ、Ⅲ、Ⅳ",{"key":23,"text":132,"correct":21},"Ⅰ、Ⅱ、Ⅲ",{"key":26,"text":134,"correct":21},"Ⅱ、Ⅲ",{"key":29,"text":136,"correct":31},"Ⅰ、Ⅲ",{"id":138,"libraryId":5,"type":9,"typeLabel":15,"stem":139,"options":140,"answer":23,"analysis":32},927837,"下列关于预应力混凝土结构构件的描述哪项是错误的？（ ）[2013年真题]",[141,143,145,147],{"key":19,"text":142,"correct":21},"预应力混凝土结构构件，除应根据设计状况进行承载力计算及正常使用极限状态验算外，尚应对施工阶段进行验算",{"key":23,"text":144,"correct":31},"预应力混凝土结构构件承载能力极限状态计算时，其支座截面最大负弯矩设计值不应进行调幅",{"key":26,"text":146,"correct":21},"计算先张法预应力混凝土构件端部锚固区的正截面和斜截面受弯承载力时，锚固长度范围内的预应力筋抗拉强度设计值在锚固起点处应取为零",{"key":29,"text":148,"correct":21},"后张预应力混凝土构件外露金属锚具，应采取可靠的防腐及防火措施，采用混凝土封闭时，其强度等级宜与构件混凝土强度等级一致，且不应低于C30",{"id":150,"libraryId":5,"type":9,"typeLabel":15,"stem":151,"options":152,"answer":19,"analysis":32},927838,"假设，某3层钢筋混凝土结构房屋，位于非抗震设防区，房屋高度9.0m，钢筋混凝土墙墙厚200mm，配置双层双向分布钢筋。试问，墙体双层水平分布钢筋的总配筋率最小值及双层竖向分布钢筋的总配筋率最小值分别与下列何项数值最为接近？（ ）[2012年真题]",[153,155,157,159],{"key":19,"text":154,"correct":31},"0.15％，0.15％",{"key":23,"text":156,"correct":21},"0.20％，0.15％",{"key":26,"text":158,"correct":21},"0.20％，0.20％",{"key":29,"text":160,"correct":21},"0.30％，0.30％",{"id":162,"libraryId":5,"type":9,"typeLabel":15,"stem":163,"options":164,"answer":29,"analysis":32},927839,"某7度区某钢筋混凝土标准设防类多层建筑，设计地震分组为第二组，设计基本地震加速度为0.1g，场地类别为Ⅱ类。[2012年真题] 1.试问，罕遇地震下弹塑性位移验算时的水平地震影响系数最大值 应分别采用下列何项数值？（ ）",[165,167,169,171],{"key":19,"text":166,"correct":21},"0.08，0.35",{"key":23,"text":168,"correct":21},"0.12，0.40",{"key":26,"text":170,"correct":21},"0.50，0.40",{"key":29,"text":172,"correct":31},"0.50，0.45",{"id":174,"libraryId":5,"type":9,"typeLabel":15,"stem":175,"options":176,"answer":19,"analysis":32},927840,"某7度区某钢筋混凝土标准设防类多层建筑，设计地震分组为第二组，设计基本地震加速度为0.1g，场地类别为Ⅱ类。[2012年真题] .假设，该建筑结构本身的计算自振周期为0.5s，周期折减系数为0.8。试问，多遇地震作用下的水平地震影响系数与下列何项数值最为接近？（ ）",[177,179,181,183],{"key":19,"text":178,"correct":31},"0.08",{"key":23,"text":180,"correct":21},"0.09",{"key":26,"text":182,"correct":21},"0.10",{"key":29,"text":184,"correct":21},"0.12",{"id":186,"libraryId":5,"type":9,"typeLabel":15,"stem":187,"options":188,"answer":29,"analysis":32},927841,"某钢筋混凝土框架柱，抗震等级为四级，截面为b×h=400mm×400mm，采用C25混凝土，经计算，轴压比=0.40，剪跨比大于2.0。现拟采用HRB400钢筋作为复合箍。试问，该柱上下端加密区箍筋的最小体积配箍百分率与下列何项数值最为接近？（ ）[2012年真题]",[189,191,193,195],{"key":19,"text":190,"correct":21},"0.23％",{"key":23,"text":192,"correct":21},"0.28％",{"key":26,"text":194,"correct":21},"0.32％",{"key":29,"text":196,"correct":31},"0.40％",{"id":198,"libraryId":5,"type":9,"typeLabel":15,"stem":199,"options":200,"answer":19,"analysis":32},927842,"某钢筋混凝土连续梁，截面高度为3900mm，截面宽度为300mm，计算跨度为6000mm，混凝土强度等级为C40，不考虑抗震。梁的水平和竖向分布筋配置符合规范要求。试问，此梁要求不出现斜裂缝时，中间支座截面对应于标准组合的抗剪承载力（kN）与下列何项数值最为接近？（ ）[2012年真题] 提示：结构安全等级二级。",[201,203,205,207],{"key":19,"text":202,"correct":31},"1120",{"key":23,"text":204,"correct":21},"1250",{"key":26,"text":206,"correct":21},"1380",{"key":29,"text":208,"correct":21},"2680",{"id":210,"libraryId":5,"type":9,"typeLabel":15,"stem":211,"options":212,"answer":26,"analysis":32},927843,"关于钢筋混凝土构件的以下3种说法： Ⅰ．局部受压承载力计算公式两侧均为设计值； Ⅱ．裂缝宽度计算时，荷载组合的效应为准永久值，而不是设计值； Ⅲ．非预应力钢筋混凝土受弯构件最大挠度按荷载准永久组合，并考虑荷载长期作用的影响进行计算。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[213,215,217,219],{"key":19,"text":214,"correct":21},"Ⅰ、Ⅱ正确，Ⅲ错误",{"key":23,"text":216,"correct":21},"Ⅱ、Ⅲ正确，Ⅰ错误",{"key":26,"text":218,"correct":31},"Ⅰ、Ⅲ正确，Ⅱ错误",{"key":29,"text":220,"correct":21},"Ⅰ、Ⅱ、Ⅲ均正确",{"id":222,"libraryId":5,"type":9,"typeLabel":15,"stem":223,"options":224,"answer":26,"analysis":32},927844,"关于预制构件吊环的以下3种说法： Ⅰ．应采用HPB300或更高强度的钢筋制作。当采用HRB335级钢筋时，末端可不设弯钩； Ⅱ．宜采用HPB300级钢筋制作。考虑到该规格材料用量可能很少，采购较难，也允许采用HRB335级钢筋制作，但其容许应力和锚固均应按HPB300级钢筋采用； Ⅲ．应采用HPB300级钢筋。在过渡期内允许使用HPB235级钢筋，但应控制截面的应力不超过50N\u002Fmm2。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[225,227,229,231],{"key":19,"text":226,"correct":21},"Ⅰ、Ⅱ、Ⅲ均错误",{"key":23,"text":228,"correct":21},"Ⅰ正确，Ⅱ、Ⅲ错误",{"key":26,"text":230,"correct":31},"Ⅱ正确，Ⅰ、Ⅲ错误",{"key":29,"text":232,"correct":21},"Ⅲ正确，Ⅰ、Ⅱ错误",{"id":234,"libraryId":5,"type":9,"typeLabel":15,"stem":235,"options":236,"answer":26,"analysis":32},927845,"某框架结构钢筋混凝土办公楼，安全等级为二级，梁板布置如图所示。框架的抗震等级为三级，混凝土强度等级为C30，梁板均采用HRB400级钢筋。板面恒载标准值5.0kN／m2（含板自重），活荷载标准值2.0kN／m2，梁上恒荷载标准值10.0kN／m（含梁及梁上墙自重）。[2014年真题] 1.假定，现浇板板厚120mm，板跨中弯矩设计值M=5.0kN·m，as=20mm。试问，跨中板底按承载力设计所需的钢筋面积As（mm2\u002Fm），与下列何项数值最为接近？（ ） 提示：不考虑板面受压钢筋作用。",[237,239,241,243],{"key":19,"text":238,"correct":21},"145",{"key":23,"text":240,"correct":21},"180",{"key":26,"text":242,"correct":31},"215",{"key":29,"text":244,"correct":21},"240",{"id":246,"libraryId":5,"type":9,"typeLabel":15,"stem":247,"options":248,"answer":26,"analysis":32},927846,"某框架结构钢筋混凝土办公楼，安全等级为二级，梁板布置如图所示。框架的抗震等级为三级，混凝土强度等级为C30，梁板均采用HRB400级钢筋。板面恒载标准值5.0kN／m2（含板自重），活荷载标准值2.0kN／m2，梁上恒荷载标准值10.0kN／m（含梁及梁上墙自重）。[2014年真题] 假定，框架梁KL1的截面尺寸为350mm×800mm， 框架支座截面处梁底配有 的受压钢筋，梁顶面受拉钢筋可按需配置且满足规范最大配筋率限值要求。试问，考虑受压区受力钢筋作用时，KL1支座处正截面最大抗震受弯承载力设计值M（kN·m），与下列何项数值最为接近？（ ）",[249,251,253,255],{"key":19,"text":250,"correct":21},"1252",{"key":23,"text":252,"correct":21},"1510",{"key":26,"text":254,"correct":31},"1670",{"key":29,"text":256,"correct":21},"2010",{"id":258,"libraryId":5,"type":9,"typeLabel":15,"stem":259,"options":260,"answer":26,"analysis":32},927847,"某框架结构钢筋混凝土办公楼，安全等级为二级，梁板布置如图所示。框架的抗震等级为三级，混凝土强度等级为C30，梁板均采用HRB400级钢筋。板面恒载标准值5.0kN／m2（含板自重），活荷载标准值2.0kN／m2，梁上恒荷载标准值10.0kN／m（含梁及梁上墙自重）。[2014年真题] 假定，框架梁KL2的截面尺寸为350mm×800mm， 框架支座截面处顶面实配钢筋为12Φ25，底面实配钢筋为4Φ25。试问，梁端箍筋配置选用下列何项才能符合规范的最低构造要求？（ ）",[261,263,265,267],{"key":19,"text":262,"correct":21},"Φ8@150（4）",{"key":23,"text":264,"correct":21},"Φ8@100（4）",{"key":26,"text":266,"correct":31},"Φ10@150（4）",{"key":29,"text":268,"correct":21},"Φ10@100（4）",{"id":270,"libraryId":5,"type":9,"typeLabel":15,"stem":271,"options":272,"answer":19,"analysis":32},927848,"某两层单建式地下车库如图，用于停放载人少于9人的小客车，设计使用年限为50年，采用框架结构，双向柱跨均为8m，各层均采用不设次梁的双向板楼盖，顶板覆土厚度s=2.5m（覆土应力扩散角=?35°），地面为小客车通道（可作为全车总重300kN的重型消防车通道），剖面如图1所示，抗震设防烈度为8度，设计基本地震加速度为0.20g，设计地震分组第二组，建筑场地类别为Ⅲ类，抗震设防类别为标准设防类，安全等级为二级。 [2013年真题] 试问，计算地下车库顶板楼盖承载力时，消防车的等效均布活荷载标准值 与下列何项数值最为接近？（ ） 提示：消防车的等效均布活荷载考虑覆土厚度影响的折减系数，可按6m×6m的双向板楼盖取值。",[273,275,276,278],{"key":19,"text":274,"correct":31},"16",{"key":23,"text":88,"correct":21},{"key":26,"text":277,"correct":21},"28",{"key":29,"text":279,"correct":21},"35",{"id":281,"libraryId":5,"type":9,"typeLabel":15,"stem":282,"options":283,"answer":23,"analysis":32},927849,"某两层单建式地下车库如图，用于停放载人少于9人的小客车，设计使用年限为50年，采用框架结构，双向柱跨均为8m，各层均采用不设次梁的双向板楼盖，顶板覆土厚度s=2.5m（覆土应力扩散角=?35°），地面为小客车通道（可作为全车总重300kN的重型消防车通道），剖面如图1所示，抗震设防烈度为8度，设计基本地震加速度为0.20g，设计地震分组第二组，建筑场地类别为Ⅲ类，抗震设防类别为标准设防类，安全等级为二级。 [2013年真题] 假定，地下车库顶板的厚度h=250mm，混凝土强度等级为C30，采用HRB400钢筋，顶板跨中位置板底钢筋为 试问，考虑受压区楼板钢筋时，板跨中位置正截面受弯承载力设计值M（kN·m／m），与下列何项数值最为接近？（ ）",[284,286,288,290],{"key":19,"text":285,"correct":21},"80",{"key":23,"text":287,"correct":31},"105",{"key":26,"text":289,"correct":21},"125",{"key":29,"text":291,"correct":21},"135",{"id":293,"libraryId":5,"type":9,"typeLabel":15,"stem":294,"options":295,"answer":29,"analysis":32},927850,"某两层单建式地下车库如图，用于停放载人少于9人的小客车，设计使用年限为50年，采用框架结构，双向柱跨均为8m，各层均采用不设次梁的双向板楼盖，顶板覆土厚度s=2.5m（覆土应力扩散角=?35°），地面为小客车通道（可作为全车总重300kN的重型消防车通道），剖面如图1所示，抗震设防烈度为8度，设计基本地震加速度为0.20g，设计地震分组第二组，建筑场地类别为Ⅲ类，抗震设防类别为标准设防类，安全等级为二级。 [2013年真题] 试问，当框架柱纵筋采用HRB400钢筋时，柱A的纵向钢筋最小总配筋率（％）应不小于下列何项数值？（ ）",[296,298,300,302],{"key":19,"text":297,"correct":21},"0.65",{"key":23,"text":299,"correct":21},"0.75",{"key":26,"text":301,"correct":21},"0.85",{"key":29,"text":303,"correct":31},"0.95",{"id":305,"libraryId":5,"type":9,"typeLabel":15,"stem":306,"options":307,"answer":23,"analysis":32},927851,"某两层单建式地下车库如图，用于停放载人少于9人的小客车，设计使用年限为50年，采用框架结构，双向柱跨均为8m，各层均采用不设次梁的双向板楼盖，顶板覆土厚度s=2.5m（覆土应力扩散角=?35°），地面为小客车通道（可作为全车总重300kN的重型消防车通道），剖面如图1所示，抗震设防烈度为8度，设计基本地震加速度为0.20g，设计地震分组第二组，建筑场地类别为Ⅲ类，抗震设防类别为标准设防类，安全等级为二级。 [2013年真题] 假定，地下一层楼盖楼梯间位置框架梁承受次梁传递的集中力设计值F=295kN，如图2-6所示，附加箍筋采用HPB300钢筋，吊筋采用HRB400钢筋，其中集中荷载两侧附加箍筋各为",[308,309,311,312],{"key":19,"text":32,"correct":21},{"key":23,"text":310,"correct":31},"（两肢箍），吊筋夹角α=60°。试问，至少应选用下列何种吊筋才能满足承受集中荷载F的要求？（ ）",{"key":26,"text":32,"correct":21},{"key":29,"text":32,"correct":21},{"id":314,"libraryId":5,"type":9,"typeLabel":15,"stem":315,"options":316,"answer":23,"analysis":32},927852,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 1.假定，厂房所在地区基本风压w0=0.45kN／m2，场地平坦，地面粗糙度为B类，室外地坪标高为－0.300m。试问，厂房中间一榀排架的屋架传给排架柱顶的风荷载标准值Wk（kN），与下列何项数值最为接近？（ ） 提示：βz=1.0，风压高度系数μz按柱顶标高取值。",[317,319,321,323],{"key":19,"text":318,"correct":21},"6.0",{"key":23,"text":320,"correct":31},"6.6",{"key":26,"text":322,"correct":21},"7.1",{"key":29,"text":324,"correct":21},"8.0",{"id":326,"libraryId":5,"type":9,"typeLabel":15,"stem":327,"options":328,"answer":19,"analysis":32},927853,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 当计算厂房纵向地震作用时，按《建筑抗震设计规范》（GB 50011—2010）估算的厂房纵向基本周期T（s），与下列何项数值最为接近？（ ）",[329,331,333,335],{"key":19,"text":330,"correct":31},"0.4",{"key":23,"text":332,"correct":21},"0.6",{"key":26,"text":334,"correct":21},"0.8",{"key":29,"text":336,"correct":21},"1.1",{"id":338,"libraryId":5,"type":9,"typeLabel":15,"stem":339,"options":340,"answer":26,"analysis":32},927854,"某单层等高等跨厂房，排架结构图所示，安全等级为二级。厂房长度为66m，排架间距B=6m，两端山墙，采用砖围护墙及钢屋架，屋面支撑系统完整。柱及牛腿混凝土强度等级为C30，纵筋采用HRB400。[2013年真题] 假定，柱A下柱截面b×h为400mm×600mm，非抗震设计时，控制配筋的内力组合弯矩设计值M=250kN·m，相应的轴力设计值N=500kN，采用对称配筋，as=as′=40mm，相对受压区高度为ξb=0.518，初始偏心距ei=520mm。试问，柱一侧纵筋截面面积As（mm2），与下列何项数值最为接近？（ ）",[341,342,344,346],{"key":19,"text":76,"correct":21},{"key":23,"text":343,"correct":21},"610",{"key":26,"text":345,"correct":31},"710",{"key":29,"text":347,"correct":21},"920",{"id":349,"libraryId":5,"type":9,"typeLabel":15,"stem":350,"options":351,"answer":23,"analysis":32},927855,"某单跨简支独立梁受力简图如图所示。简支梁截面尺寸为300mm×850mm（ho=815mm），混凝土强度等级为C30，梁箍筋采用HPB300钢筋，安全等级为二级。[2013年真题]",[352,354,355,357],{"key":19,"text":353,"correct":21},"1.假定，该梁承受的剪力设计值V=260kN。试问，下列梁箍筋配置何项满足《混凝土结构设计规范》（G50010—2010）的构造要求？（ ）",{"key":23,"text":32,"correct":31},{"key":26,"text":356,"correct":21},"提示：假定，以下各项均满足计算要求。",{"key":29,"text":32,"correct":21},{"id":359,"libraryId":5,"type":9,"typeLabel":15,"stem":360,"options":361,"answer":26,"analysis":32},927856,"某单跨简支独立梁受力简图如图所示。简支梁截面尺寸为300mm×850mm（ho=815mm），混凝土强度等级为C30，梁箍筋采用HPB300钢筋，安全等级为二级。[2013年真题] 假定，集中力设计值F=250kN，均布荷载设计值q=15kN／m。试问，当箍筋为10@200（2）时，梁斜截面受剪承载力设计值（kN），与下列何项数值最为接近？（ ）",[362,364,366,368],{"key":19,"text":363,"correct":21},"250",{"key":23,"text":365,"correct":21},"300",{"key":26,"text":367,"correct":31},"350",{"key":29,"text":369,"correct":21},"400",{"id":371,"libraryId":5,"type":9,"typeLabel":15,"stem":372,"options":373,"answer":23,"analysis":32},927857,"某混凝土构件局部受压情况如图所示，局部受压范围无孔洞、凹槽，并忽略边距的影响，混凝土强度等级为C25，安全等级为二级。[2013年真题] 假定，局部受压作用尺寸a=300mm，b=200mm。试问，进行混凝土局部受压验算时，其计算底面积Ab（mm2）与下列何项数值最为接近？（ ）",[374,376,378,380],{"key":19,"text":375,"correct":21},"300000",{"key":23,"text":377,"correct":31},"420000",{"key":26,"text":379,"correct":21},"560000",{"key":29,"text":381,"correct":21},"720000",{"id":383,"libraryId":5,"type":9,"typeLabel":15,"stem":384,"options":385,"answer":19,"analysis":32},927858,"某框架结构中间楼层端部梁柱节点如图所示，框架抗震等级为二级，梁柱混凝土强度等级均为C35，框架梁上部纵筋为 弯折前的水平段长l1=560mm。试问，框架梁上部纵筋满足抗震构造要求的最小总锚固长度l（mm）与下列何项数值最为接近？（ ）[2013年真题]",[386,388,390,392],{"key":19,"text":387,"correct":31},"980",{"key":23,"text":389,"correct":21},"1086",{"key":26,"text":391,"correct":21},"1195",{"key":29,"text":393,"correct":21},"1245",{"id":395,"libraryId":5,"type":9,"typeLabel":15,"stem":396,"options":397,"answer":19,"analysis":32},927859,"某2层钢筋混凝土办公楼浴室的简支楼面梁如图，安全等级为二级，从属面积为13.5，计算跨度为6.0m，梁上作用恒荷载标准值gk=14.0kN\u002Fm（含梁自重），按等效均布荷载计算的梁上活荷载标准值=4.5kN\u002Fm。[2012年真题] 试问，梁跨中弯矩基本组合设计值M（kN·m）、标准组合设计值Mk（kN·m）、准永久组合设计值（kN·m）分别与下列何项数值最为接近？（ ）",[398,399,400,401],{"key":19,"text":19,"correct":31},{"key":23,"text":23,"correct":21},{"key":26,"text":26,"correct":21},{"key":29,"text":29,"correct":21},{"id":403,"libraryId":5,"type":9,"typeLabel":15,"stem":404,"options":405,"answer":26,"analysis":32},927860,"某2层钢筋混凝土办公楼浴室的简支楼面梁如图，安全等级为二级，从属面积为13.5，计算跨度为6.0m，梁上作用恒荷载标准值gk=14.0kN\u002Fm（含梁自重），按等效均布荷载计算的梁上活荷载标准值=4.5kN\u002Fm。[2012年真题] 假定，该梁两端均与框架柱刚接，当进行截面抗震验算时，试问，该梁在重力荷载代表值作用下按简支梁计算的梁端剪力设计值VGb（kN）与下列何项数值最为接近？（ ） 提示：假定重力荷载对该梁抗震不利。 {图}",[406,408,410,412],{"key":19,"text":407,"correct":21},"40",{"key":23,"text":409,"correct":21},"50",{"key":26,"text":411,"correct":31},"60",{"key":29,"text":413,"correct":21},"65",{"id":415,"libraryId":5,"type":9,"typeLabel":15,"stem":416,"options":417,"answer":29,"analysis":32},927861,"某6度区标准设防类钢筋混凝土框架结构办公楼如图，房屋高度为22m，地震分组为第一组，场地类别为Ⅱ类。其中一根框架角柱，分别与跨度为8m和10m的框架梁相连，剪跨比为1.90，截面及配筋如图3所示，混凝土强度等级C40。试问，该框架柱的轴压比限值与下列何项数值最为接近？（ ）[2012年真题] 提示：可不复核柱的最小配箍特征值。",[418,420,421,423],{"key":19,"text":419,"correct":21},"0.80",{"key":23,"text":301,"correct":21},{"key":26,"text":422,"correct":21},"0.90",{"key":29,"text":303,"correct":31},{"id":425,"libraryId":5,"type":9,"typeLabel":15,"stem":426,"options":427,"answer":23,"analysis":32},927862,"某规则结构各层平面如图所示，荷载分布较均匀。现采用简化方法，按X、Y两个正交方向分别计算水平地震作用效应（不考虑扭转），并通过将该地震作用效应乘以放大系数来考虑地震扭转效应。试根据《建筑抗震设计规范》（GB 50011—2010）判断，下列框架的地震作用效应增大系数，其中何项较为合适？（ ）[2012年真题]",[428,430,432,434],{"key":19,"text":429,"correct":21},"KJ1：1.02",{"key":23,"text":431,"correct":31},"KJ3：1.05",{"key":26,"text":433,"correct":21},"K13：1.15",{"key":29,"text":435,"correct":21},"KJ2、KJ4：1.10",{"id":437,"libraryId":5,"type":9,"typeLabel":15,"stem":438,"options":439,"answer":26,"analysis":32},927863,"某钢筋混凝土简支梁图，其截面可以简化成工字形，混凝土强度等级为C30，纵向钢筋采用HRB400，纵向钢筋的保护层厚度为28mm，受拉钢筋合力点至梁截面受拉边缘的距离为40mm。该梁不承受地震作用，不直接承受重复荷载，安全等级为二级。[2012年真题] 试问，该梁纵向受拉钢筋的构造最小配筋量（mm2）与下列何项数值最为接近？（ ）",[440,442,443,444],{"key":19,"text":441,"correct":21},"200",{"key":23,"text":98,"correct":21},{"key":26,"text":365,"correct":31},{"key":29,"text":369,"correct":21},{"id":446,"libraryId":5,"type":9,"typeLabel":15,"stem":447,"options":448,"answer":26,"analysis":32},927864,"某钢筋混凝土简支梁图，其截面可以简化成工字形，混凝土强度等级为C30，纵向钢筋采用HRB400，纵向钢筋的保护层厚度为28mm，受拉钢筋合力点至梁截面受拉边缘的距离为40mm。该梁不承受地震作用，不直接承受重复荷载，安全等级为二级。[2012年真题]",[449,450,452,454],{"key":19,"text":32,"correct":21},{"key":23,"text":451,"correct":21},"若该梁承受的弯矩设计值为310kN·m，并按单筋梁进行配筋计算。试问，按承载力要求该梁纵向受拉钢筋选择下列何项最为安全经济？（ ）",{"key":26,"text":453,"correct":31},"提示：不必验算最小配筋率。",{"key":29,"text":32,"correct":21},{"id":456,"libraryId":5,"type":9,"typeLabel":15,"stem":447,"options":457,"answer":26,"analysis":32},927865,[458,460,462,464],{"key":19,"text":459,"correct":21},"0.17",{"key":23,"text":461,"correct":21},"0.29",{"key":26,"text":463,"correct":31},"0.33",{"key":29,"text":465,"correct":21},"0.45",{"id":467,"libraryId":5,"type":9,"typeLabel":15,"stem":468,"options":469,"answer":29,"analysis":32},927866,"关于非抗震预应力混凝土受弯构件受拉一侧受拉钢筋的最小配筋百分率的以下3种说法： Ⅰ．预应力钢筋的配筋百分率不得少于0.2和45∫z\u002F∫y的较大值； Ⅱ．非预应力钢筋的最小配筋百分率为0.2； Ⅲ．受拉钢筋最小配筋百分率不得少于按正截面受弯承载力设计值等于正截面开裂弯矩值的原则确定的配筋百分率。 试问，针对上述说法正确性的判断，下列何项正确？（ ）[2012年真题]",[470,471,472,473],{"key":19,"text":226,"correct":21},{"key":23,"text":228,"correct":21},{"key":26,"text":230,"correct":21},{"key":29,"text":232,"correct":31},{"id":475,"libraryId":5,"type":9,"typeLabel":15,"stem":476,"options":477,"answer":29,"analysis":32},927867,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 6.已知：B栋底层边柱KZ3截面及配筋示意如图2-20所示，考虑地震作用组合的柱轴压力设计值N=4120kN，该柱剪跨比λ=2.5，该柱混凝土强度等级为C40，箍筋采用HPB235级钢筋，纵向受力钢筋的混凝土保护层厚度c=30mm。如仅从抗震构造措施方面考虑，试问，该柱选用下列何项箍筋配置（复合箍）最为恰当？（ ）提示：按《建筑抗震设计规范》（GB 50011—2010）作答。为简化计算，扣除重叠部分箍筋。",[478,480,482,484],{"key":19,"text":479,"correct":21},"Φ10@100\u002F200",{"key":23,"text":481,"correct":21},"Φ10@100",{"key":26,"text":483,"correct":21},"Φ12@100\u002F200",{"key":29,"text":485,"correct":31},"Φ12@100",{"id":487,"libraryId":5,"type":9,"typeLabel":15,"stem":488,"options":489,"answer":19,"analysis":32},927868,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 5.已知：A栋房屋的抗震等级为二级，A栋底层中柱KZl的柱净高Hn=2.5m，柱上节点梁端截面顺时针或逆时针方向组合的弯矩设计值∑Mb=360kN·m，柱下端截面组合的弯矩设计值Mn=320kN·m，反弯点在柱层高范围内，柱轴压比为0.5。试问，为实现“强柱弱梁”及“强剪弱弯”，按规范调整后该柱的组合剪力设计值V（kN），与下列何项数值最为接近？（ ） 提示：①柱上节点上、下柱端的弯矩设计值按平均分配。②",[490,492,494,496],{"key":19,"text":491,"correct":31},"390",{"key":23,"text":493,"correct":21},"430",{"key":26,"text":495,"correct":21},"470",{"key":29,"text":497,"correct":21},"530",{"id":499,"libraryId":5,"type":9,"typeLabel":15,"stem":500,"options":501,"answer":26,"analysis":32},927869,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 3.经估算，A栋底层中柱KZl考虑地震作用组合的轴压力设计值N=5490kN，假定该柱混凝土强度等级为C40，剪跨比λ=1.8，箍筋采用直径Ф10的井字复合箍（非螺旋箍）且未配置芯柱，试问，该框架柱最小截面尺寸b（mm）×h（mm）选用下列何项时，满足规范最低抗震构造要求？（ ）",[502,504,506,508],{"key":19,"text":503,"correct":21},"550×550",{"key":23,"text":505,"correct":21},"600×600",{"key":26,"text":507,"correct":31},"650×650",{"key":29,"text":509,"correct":21},"700×700",{"id":511,"libraryId":5,"type":9,"typeLabel":15,"stem":512,"options":513,"answer":23,"analysis":32},927870,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 1.试问，该防震缝的宽度δ（mm）至少应取下列何项数值？（ ）",[514,516,518,520],{"key":19,"text":515,"correct":21},"110",{"key":23,"text":517,"correct":31},"140",{"key":26,"text":519,"correct":21},"150",{"key":29,"text":240,"correct":21},{"id":522,"libraryId":5,"type":9,"typeLabel":15,"stem":523,"options":524,"answer":29,"analysis":32},927871,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 2.关关于抗撞墙的布置及设计，下列所述何项正确？（ ）",[525,527,529,531],{"key":19,"text":526,"correct":21},"在缝两侧沿房屋全高各设置不少于一道垂直于防震缝的抗撞墙",{"key":23,"text":528,"correct":21},"抗撞墙的布置宜避免加大扭转效应，其长度应大于1\u002F2层高",{"key":26,"text":530,"correct":21},"抗撞墙的抗震等级应比其框架结构提高一级",{"key":29,"text":532,"correct":31},"框架构件的内力应按设置和不设置抗撞墙两种计算模型的不利情况取值",{"id":534,"libraryId":5,"type":9,"typeLabel":15,"stem":535,"options":536,"answer":29,"analysis":32},927872,"某钢筋混凝土框架结构办公楼如图，柱距均为8.4m。由于两侧结构层高相差较大且有错层，设计时拟设置防震缝，并在缝两侧设置抗撞墙，如图1所示。已知：该房屋抗震设防类别为丙类，抗震设防烈度为8度，建筑场地类别为Ⅱ类，建筑安全等级为二级。A栋房屋高度为21m，B栋房屋高度为27m。[2011年真题] 假定，A栋二层中柱KZl截面尺寸b×h=600mm×600mm，ho=555mm。柱净高Hn=2.5m，柱上、下端截面考虑地震作用组合的弯矩计算值分别为Mct=280kN·m、Mcb=470kN·m，弯矩均为顺时针或逆时针方向。试问，该框架柱的剪跨比λ取下列何项数值最为合适？（ ） 提示：采用公式",[537,539,541,543],{"key":19,"text":538,"correct":21},"1.7",{"key":23,"text":540,"correct":21},"2.2",{"key":26,"text":542,"correct":21},"2.6",{"key":29,"text":544,"correct":31},"2.8",{"id":546,"libraryId":5,"type":9,"typeLabel":15,"stem":547,"options":548,"answer":23,"analysis":32},927873,"某车间内设有一台电动葫芦如图，其轨道梁吊挂于钢梁AB下。钢梁两端连接于厂房框架柱上，计算跨度L=7000mm，计算简图如图所示。钢材采用Q235—B钢，钢梁选用热轧H型钢HN400×200×8×13，其截面特性：A=83.37×102mm2，Ιz=23500×10?mm?,Wx=1170×103mm3,iy=45.6mm。[2012年真题] 1.为便于对钢梁AB进行计算，将电动葫芦轨道梁、相关连接件和钢梁等自重折合为一集中荷载标准值Gk=6kN，作用于C点处钢梁下翼缘，电动葫芦自重和吊重合计的荷载标准值Qk=66kN（按动力荷载考虑），不考虑电动葫芦的水平荷载。已知C点处钢梁对x轴的净截面模量Wyx=1050×103mm3。试问，钢梁C点处的最大应力计算数值（N\u002Fmm2）应与下列何项数值最为接近？（ ）",[549,550,551,552],{"key":19,"text":441,"correct":21},{"key":23,"text":20,"correct":31},{"key":26,"text":519,"correct":21},{"key":29,"text":553,"correct":21},"130",{"id":555,"libraryId":5,"type":9,"typeLabel":15,"stem":556,"options":557,"answer":26,"analysis":32},927874,"某车间内设有一台电动葫芦如图，其轨道梁吊挂于钢梁AB下。钢梁两端连接于厂房框架柱上，计算跨度L=7000mm，计算简图如图所示。钢材采用Q235—B钢，钢梁选用热轧H型钢HN400×200×8×13，其截面特性：A=83.37×102mm2，Ιz=23500×10?mm?,Wx=1170×103mm3,iy=45.6mm。[2012年真题] 已知条件同题（1）。试问，钢梁C点处由可变荷载Qk产生的最大挠度值（mm）应与下列何项数值最为接近？（ ）",[558,560,562,564],{"key":19,"text":559,"correct":21},"4",{"key":23,"text":561,"correct":21},"6",{"key":26,"text":563,"correct":31},"10",{"key":29,"text":565,"correct":21},"14",{"id":567,"libraryId":5,"type":9,"typeLabel":15,"stem":568,"options":569,"answer":26,"analysis":32},927875,"某钢筋混凝土T形悬臂梁，安全等级为一级，混凝土强度C30，纵向受拉钢筋采用HRB335级钢筋，不考虑抗震设计。荷载简图及截面尺寸如图2-21所示。梁上作用有均布恒荷载标准值gk（已计入梁自重）。局部均布活荷载标准值qk，集中恒荷载标准值Pk。[2011年真题] 1.已知：gk=15kN\u002Fm，qk=6kN\u002Fm，Pk=20kN，活荷载的分项系数为1.4，活荷载的组合值系数为0.7。试问，构件承载能力设计时，悬臂梁根部截面按荷载效应组合的最大弯矩设计值Ma（kN·m）与下列何项数值最为接近？（ ）",[570,572,574,576],{"key":19,"text":571,"correct":21},"580",{"key":23,"text":573,"correct":21},"600",{"key":26,"text":575,"correct":31},"620",{"key":29,"text":577,"correct":21},"640",{"id":579,"libraryId":5,"type":9,"typeLabel":15,"stem":580,"options":581,"answer":26,"analysis":32},927876,"某钢筋混凝土T形悬臂梁，安全等级为一级，混凝土强度C30，纵向受拉钢筋采用HRB335级钢筋，不考虑抗震设计。荷载简图及截面尺寸如图2-21所示。梁上作用有均布恒荷载标准值gk（已计入梁自重）。局部均布活荷载标准值qk，集中恒荷载标准值Pk。[2011年真题] 2.假定，悬臂梁根部截面按荷载效应组合的最大弯矩设计值Ma=850kN·m，as=60mm。试问，在不考虑受压钢筋作用的情况下，按承载能力极限状态设计，纵向受拉钢筋的截面面积As（mm2）与下列何项数值最为接近？（ ）提示：相对界限受压区高度ξb=0.55。",[582,584,586,588],{"key":19,"text":583,"correct":21},"3500",{"key":23,"text":585,"correct":21},"3900",{"key":26,"text":587,"correct":31},"4300",{"key":29,"text":589,"correct":21},"4700",[591,594,597,600,603,606],{"id":9,"name":592,"category":7,"favorite":593},"领导干部任职前廉政法规知识测试题",92,{"id":595,"name":596,"category":7,"favorite":9},595,"建筑结构与设备",{"id":598,"name":599,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":601,"name":602,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":604,"name":605,"category":7,"favorite":8},534,"BIM工程师",{"id":607,"name":605,"category":7,"favorite":8},535]