[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928549":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928549,599,1,"单选题","某框架结构钢筋混凝土办公楼，安全等级为二级，梁板布置如图所示。框架的抗震等级为三级，混凝土强度等级为C30，梁板均采用HRB400级钢筋。板面恒载标准值5.0kN／m2（含板自重），活荷载标准值2.0kN／m2，梁上恒荷载标准值10.0kN／m（含梁及梁上墙自重）。试问，配筋设计时，次梁L1上均布线荷载的组合设计值q（kN／m），与下列何项数值最为接近？（ ）[2014年真题] 提示：荷载传递按单向板考虑。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","37",false,{"key":16,"text":17,"correct":14},"B","38",{"key":19,"text":20,"correct":21},"C","39",true,{"key":23,"text":24,"correct":14},"D","40","根据《建筑结构荷载规范》（GB 50009—2012）第3.2.3条、第3.2.4条及第5.1.2条进行计算：次梁的从属面积为3×9=27m2>25m2，活荷载折减系数取0.9。 由永久荷载控制的效应设计值：q=1.35×（5.0×3+10.0）+1.4×0.7×2.0×3×0.9=39.0kN／m。 由可变荷载控制的效应设计值：q=1.2×（5.0×3+10.0）+1.4×2.0×3×0.9=37.56kN／m\u003C39.0kN／m，取q=39.0kN／m。 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]