[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928540":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928540,599,1,"单选题","有一连梁的截面尺寸为b×h=160mm×900mm，净跨ln=900mm，抗震等级为二级，纵筋HRB335级，fy=300N\u002Fmm2，箍筋HPB300级，fyv=270N\u002Fmm2，混凝土强度为C30，fc=14.3N\u002Fmm2，ft=1.43N\u002Fmm2。由楼层荷载传到连梁上的剪力VGb很小，略去不计。由地震作用产生的连梁剪力设计值Vb=150kN。 4.连梁每侧的腰筋配置最接近于（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","4φ10",false,{"key":16,"text":17,"correct":14},"B","4φ8",{"key":19,"text":20,"correct":21},"C","4φ12",true,{"key":23,"text":24,"correct":14},"D","3φ10","根据《高层建筑混凝土结构技术规程》（JGJ 3—2010）第7.2.27条第4款规定，连梁截面高度大于700mm时，其两侧腰筋的直径不应小于8mm，间距不应大于200mm；跨高比不大于2.5的连梁，其两侧腰筋的总面积配筋率不应小于0.3%； 每侧选择4根钢筋，As=0.3%A=0.3%×160×865=415.2mm2，则415.2\u002F4=103.8mm2，选腰筋φ12，As=113.04mm2。由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]