[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928535":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928535,599,1,"单选题","一单层平面框架（见图），由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m。 现尚需计及如图所示由风荷载产生的D点弯矩标准值MDwk=25kN·m，由此算得D点组合后的弯矩设计值MD最接近于（ ）kN·m。（不采用简化规则）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","117.9",false,{"key":16,"text":17,"correct":14},"B","123.0",{"key":19,"text":20,"correct":21},"C","124.4",true,{"key":23,"text":24,"correct":14},"D","140.0","根据《建筑结构荷载规范》（GB 50009—2012）第3.2.3条规定，荷载效应组合设计值分别为： ①当按屋顶均布活荷载效应控制的组合时（风荷载的组合值系数ψc=0.6）： MD=1.2×50＋1.4×30＋1.4×0.6×25=123kN·m； ②当按风荷载效应控制的组合时（屋顶均布活荷载的组合值系ψc=0.7）： MD=1.2×50+1.4×25+1.4×0.7×30=124.4kN·m； ③当按永久荷载效应控制的组合时： MD=1.35×50+1.4×0.7×30+1.4×0.6×25=117.9kN·m； 取三者中的最大值，则应按风荷载效应控制的组合确定D点弯矩设计值MD，即MD=124.4kN·m。由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]