[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928534":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},928534,599,1,"单选题","一单层平面框架（见图），由屋顶永久荷载标准值产生的D点柱顶弯矩标准值MDgk=50kN·m。 1.由屋顶均布活荷载标准值产生的弯矩标准值MDqk=30kN·m，则D点的弯矩设计值MD最接近于（ ）kN·m。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","130",false,{"key":16,"text":17,"correct":18},"B","102",true,{"key":20,"text":21,"correct":14},"C","96.9",{"key":23,"text":24,"correct":14},"D","95","根据《建筑结构荷载规范》（GB 50009—2012）第3.2.3条规定，可变荷载效应及永久荷载效应下的荷载效应组合设计值分别计算如下： 当为屋顶均布活荷载效应控制的组合时： MD=1.2×50+1.4×30=102kN·m； 当为永久荷载效应控制的组合时： MD=1.35×50+1.4×0.7×30=96.9kN·m\u003C102kN·m； 故该效应组合由屋顶均布活荷载效应控制，即D点的弯矩设计值MD=102kN·m。由此可知，B项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]