[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928518":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928518,599,1,"单选题","10层框架—剪力墙结构，抗震设防烈度为8度，Ⅱ类场地，设计地震分组：第一组。首层层高6m，2层层高4.5m，3～10层层高3.6m，总高度39.3m。质量和刚度沿高度分布比较均匀，各楼层重力荷载代表值Gi如图所示。各楼层框架的Di值及剪力墙等效刚度如表6-5所列。采用侧移法计算在连续均布荷载作用下结构假想顶点位移μT=ψuqH4\u002F100EIw，并已知当结构刚度特征值λ=1.2时位移系数ψu=8.07。结构阻尼比ζ=0.05。 3.假定结构自振周期为T1=0.793s，结构底部由水平地震作用产生的总弯矩标准值M0（kN·m）与（ ）项数值最为接近。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","137981",true,{"key":16,"text":17,"correct":18},"B","154368",false,{"key":20,"text":21,"correct":18},"C","194018",{"key":23,"text":24,"correct":18},"D","202112","根据《建筑抗震设计规范》（GB 50011—2010）第5.1.5条图5.1.5可知，T1=0.793s＞Tg=0.35，地震影响系数为： 根据第5.2.1条规定，结构总水平地震作用标准值为：FEk=α1×0.85Geq=0.077×0.85×89500=5858kN； 当Tg=0.35s及T1=0.793s＞1.4Tg=1.4×0.35=0.49s时，查第5.2.1条表5.2.1可得，顶部附加水平地震作用系数为：δn=0.08T1+0.07=0.08×0.793+0.07=0.133； 则按式（5.2.1-2）计算，各楼层的水平地震作用标准值为： 其中FEk（1－δn）=5858×（1－0.133）=5079kN； 各楼层的水平地震作用标准值计算如表6-6所示，则结构底部由水平地震作用产生的弯矩标准值为：M0=∑FiHi=138078kN·m。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]