[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928506":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},928506,599,1,"单选题","关于柱轴压比限值的要求，下列各项不正确的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","框支剪力墙结构，抗震等级属于一级的框支柱（包括框支角柱），其轴压比不宜大于0.60",false,{"key":16,"text":17,"correct":14},"B","框架—剪力墙结构，抗震等级属一级的框架柱，当剪力墙部分承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其框架柱轴压比不宜大于0.65",{"key":19,"text":20,"correct":14},"C","框架—核心筒结构，抗震等级属一级的框架柱，当核心筒结构承受的地震倾覆力矩大于结构总地震倾覆力矩的50%时，其框架柱轴压比不宜大于0.75",{"key":22,"text":23,"correct":24},"D","筒中筒结构，抗震等级属一级的密集柱，沿柱全高采用井字复合箍，箍筋间距100mm、肢距150mm、箍径12mm；其内筒承受的地震倾覆力矩小于结构总地震倾覆力矩的50%较多时，其密集柱的轴压比不宜大于0.75",true,"筒中筒结构的受力情况，在侧向荷载作用下与框架—剪力墙结构相类似。根据《建筑抗震设计规范》（GB 50011—2010）第6.3.6条表6.3.6可知，抗震等级属于一级的外筒密集柱轴压比限值可取0.75，但又因此柱全高均以箍距不大于100mm、肢距不大于200mm、箍径又不小于12mm的井字复合箍，根据注3，轴压比限值可增大0.10。故密集柱的轴压比限值宜为0.85。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]