[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928498":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},928498,599,1,"单选题","某现浇框架—核心筒高层建筑结构，地上35层高130m，内筒为钢筋混凝土，外周边为型钢混凝土框架，抗震设防烈度为7度，丙类，设计地震分组为第一组，设计基本地震加速度为0.1g，场地类别为Ⅱ类，阻尼比ζ=0.04，结构的基本自振周期Tl=2.0s，周期折减系数取0.8。 2.抗震设计时，在水平地震作用下，对应于地震作用标准值的结构底部总剪力计算值为8800kN；对于地震作用标准值且未经调整的各层框架总剪力中，24层最大，其计算值为1600kN。则各楼层框架的剪力经调整后最接近于（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1500",false,{"key":16,"text":17,"correct":18},"B","1760",true,{"key":20,"text":21,"correct":14},"C","1920",{"key":23,"text":24,"correct":14},"D","2400","根据《高层建筑混凝土结构技术规程》（JGJ 3—2010）第8.1.4条和第9.2.3条规定，Vf≤0.2V0=0.2×8800=1760kN时，框架总剪力应按0.2V0和1.5Vf，max二者的较小值采用，则可得：1.5Vf，max=1.5×1600=2400kN；0.2V0=0.2×8800=1760kN；取较小值，则经调整后各楼层框架的剪力为1760kN。由此可知，B项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]