[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928483":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},928483,599,1,"单选题","某6层框架结构，如图所示，设防烈度为8度，设计基本地震加速度为0.209，设计地震分组为第二组，场地类别为Ⅲ类，集中在屋盖和楼盖处的重力荷载代表值为G6＝4750kN，G2-5＝6050kN，G1＝7000kN。采用底部剪力法计算。 提示：使用规范《建筑抗震设计规范》（GB 50011—2010）。 2.若该框架为钢筋混凝土结构，结构的基本自振周期T1＝0.85s，总水平地震作用标准值FEk＝3304kN，作用于顶部附加水平地震作用标准值ΔF6最接近于（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","153",false,{"key":16,"text":17,"correct":18},"B","258",true,{"key":20,"text":21,"correct":14},"C","466",{"key":23,"text":24,"correct":14},"D","525","根据《建筑抗震设计规范》（GB 50011—2010）第5.2.1条表5.2.1可知，1.4Tg＝1.4×0.55＝0.77s＜T1＝0.85s，则顶部附加地震作用系数为：δn=0.08T1＋0.01＝0.08×0.85＋0.01＝0.078。 根据第5.2.1条式（5.2.1-3）计算，作用于顶部附加水平地震作用标准值为：ΔF6=δnFEk＝0.078×3304＝258kN。由此可知，B项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]