[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928459":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928459,599,1,"单选题","一商店建筑中有一挑出长度为8m的长悬挑梁，梁上作用着永久荷载标准值的线荷载gk=30kN\u002Fm，楼面活荷载标准值的线荷载qk=20kN\u002Fm（见图）。该建筑的抗震设防烈度为8度（0.30g）。由此可算得梁端A处的最大弯矩设计值MA=（ ）kN·m。 提示：计算时应对有无竖向地震作用，以及比较永久荷载效应控制的组合与可变荷载效应控制的组合，然后确定最大弯矩设计值MA。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","2048.0",true,{"key":16,"text":17,"correct":18},"B","1923.2",false,{"key":20,"text":21,"correct":18},"C","1800.0",{"key":23,"text":24,"correct":18},"D","1785.6","根据《建筑抗震设计规范》（GB 50011—2010）相关规范进行计算： ①当考虑竖向地震作用效应组合时（γG=1.2，γEv=1.3）： 根据第5.3.3条规定，竖向地震作用标准值的线荷载gEk值取用构件上重力荷载代表值的15%进行计算，即：",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]