[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928419":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},928419,599,1,"单选题","某拟建工程，房屋高度为57.6m，地下2层，地上15层，首层层高为6.0m，二层层高为4.5m，其余各层层高均为3.6m。采用现浇钢筋混凝土框架。剪力墙结构，抗震设防烈度为7度，丙类建筑，设计基本地震加速度为0.15g，Ⅲ类场地。混凝土强度等级采用C40（fc=19.1N／mm2）。在规定的水平力作用下结构总地震倾覆力矩 底层剪力墙承受的地震倾覆力矩 3.假定，该结构首层框架，对应于水平地震作用标准值的框架柱总剪力Vf=2400kN，框架柱的侧向刚度总和 其中某边柱C1的侧向刚度DC1=17220kN／m，其反弯点高度hy=3.75m，沿柱高范围没有水平力作用。试问，在水平地震作用下，按侧向刚度计算的C1柱底弯矩标准值（kN·m），与下列何项数值最为接近？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","240",false,{"key":16,"text":17,"correct":14},"B","270",{"key":19,"text":20,"correct":21},"C","340",true,{"key":23,"text":24,"correct":14},"D","400","根据《建筑抗震设计规范》（GB 50011—2010）第5.2.3条规定，柱底剪为： 故柱底弯矩为： {图1} 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]