[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928367":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},928367,599,1,"单选题","下列关于地基处理设计方法的论述，哪项不正确？（ ）[2013年真题]",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","当地基土的天然含水量小于30％（黄土含水量小于25％），不宜采用水泥土搅拌干法",false,{"key":16,"text":17,"correct":14},"B","不加填料振冲加密桩适用于处理黏粒含量不大于10％的中砂、粗砂地基",{"key":19,"text":20,"correct":14},"C","强夯置换法和砂石桩法置换处理适用于饱和的粉土与软塑～流塑的黏性土等地基上",{"key":22,"text":23,"correct":24},"D","真空堆载联合预压法处理地基时不一定设置排水竖井",true,"根据《建筑地基处理技术规范》（JGJ 79—2012）根据第5.2.17条规定，真空预压处理地基应设置排水竖井。A项，根据第7.3.1条第1款规定，当地基土的天然含水量小于30％（黄土含水量小于25％），不宜采用水泥土搅拌干法；B项，根据第7.2.1条第3款规定，不加填料振冲加密桩适用于处理黏粒含量不大于10％的中砂、粗砂地基；C项，根据第6.1.2条和第7.2.1条第1款规定，强夯置换适用于高饱和度的粉土与软塑～流塑的黏性土等地基上对变形控制不严的工程，饱和黏土地基，如对变形控制不严格，可采用砂石桩法置换处理。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]