[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928340":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},928340,599,1,"单选题","根据《建筑桩基技术规范》（JGJ 94—2008），下列关于桩基承台设计、构造的若干主张中，其中何项是不正确的？（ ）[2011年真题]",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","柱下两桩承台不需要进行受冲切承载力计算",false,{"key":16,"text":17,"correct":18},"B","对二级抗震等级的柱，纵向主筋进入承台的锚固长度应乘以l.05的系数",true,{"key":20,"text":21,"correct":14},"C","一柱一桩时，当桩与柱的截面直径之比大于2时，可不设联系梁",{"key":23,"text":24,"correct":14},"D","承台和地下室外墙与基坑侧壁之间的间隙可用压实性较好的素土分层夯实回填，其压实系数不宜小于0.94","根据《建筑桩基技术规范》（JGJ 94—2008）逐项判别。A项，根据第5.9.7条规定，轴心竖向力作用下桩基承台受柱（墙）的冲切。B项，根据第4.2.5条第3款规定，对二级抗震等级的柱，纵向主筋锚固长度应乘以1.15的系数。C项，根据第4.2.6条第l款规定，一柱一桩时，应在桩顶两个主轴方向上设置联系梁；当桩与柱的截面直径之比大于2时，可不设联系梁。D项，根据第4.2.7条规定，承台和地下室外墙与基坑侧壁间隙应灌注素混凝土或搅拌流动性水泥土，或采用灰土、级配砂石、压实性较好的素土分层夯实，其压实系数不宜小于0.94。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]