[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928235":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},928235,599,1,"单选题","某办公楼平面布置如图所示，采用装配式钢筋混凝土楼盖，MU10砖墙承重。纵墙及横墙厚度均为240mm，砂浆强度等级M5，底层墙高H=4.5m（从基础顶面算起至一层楼板底面），隔墙厚120mm。则下列高厚比验算错误的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","外纵墙满足",false,{"key":16,"text":17,"correct":14},"B","承重横墙满足",{"key":19,"text":20,"correct":14},"C","内纵墙满足",{"key":22,"text":23,"correct":24},"D","内隔墙不满足",true,"根据《砌体结构设计规范》（GB 50003—2011）第4.2.1条表4.2.1可知，横墙最大间距s=12m＜32m，其属于刚性方案。 ①外纵墙高厚比验算 由s=12m，H=4.5m，知s=12m＞2H=9m；根据第5.1.3条表5.1.3可知， H0=1.0H； 查第6.1.1条表6.1.1可知，砂浆强度等级M5时允许高厚比[β]=24； 又μ2=1-0.4bs\u002Fs=1-0.4×2\u002F4=0.8＞0.7，由第6.1.1条式（6.1.1）计算，得：高厚比β=H0\u002Fh=4.5\u002F0.24=18.75＜μ2[β]=0.8×24=19.2，满足高厚比要求。 ②承重横墙高厚比验算 纵墙间距s=6.2m，则H=4.5m＜s＜2H=9m；根据第5.1.3条表5.1.3可知，H0=0.4s＋0.2H=0.4×6.2+0.2×4.5=3.38m； 由第6.1.1条式（6.1.1）计算，得高厚比β=H0\u002Fh=3380\u002F240=14.08＜[β]=24，满足高厚比要求。 ③内纵墙高厚比验算 由于内纵墙的厚度、砌筑砂浆、墙体高度均与纵墙相同，洞口宽度小于外墙的洞口宽度，外墙高厚比验算满足要求，则内纵墙也满足高厚比要求。 ④隔墙高厚比验算 因隔墙上端在砌筑时，一般用斜放立砖顶住楼板，故可按顶端为不动铰支点考虑。 设隔墙与纵墙咬槎拉结，则s=6.2m，2H=9m＞s＞H=4.5m； 查第5.1.3条表5.1.3可得，H0=0.4s+0.2H=3.38m； 由于隔墙是非承重墙，则 根据第6.1.1条式（6.1.1）计算，得：β=H0\u002Fh=3380\u002F120=28.16＜μ1[β]=1.44×24=34.56，满足高厚比要求。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]