[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928230":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928230,599,1,"单选题","某三层商住楼，底层局部采用两跨连续墙梁结构。局部平面图及剖面如图所示。开间为3.3m，底层层高3.9m，其余两层为3.0m，墙厚为190mm。托梁下均设有壁柱（每边凸出墙面200mm×590mm）。墙体采用MU10混凝土砌块和Mb10混合浆砌筑（f＝2.79MPa）。楼盖及屋盖采用钢筋混凝土现浇板，厚120mm。托梁混凝土采用C30（fc＝14.3N\u002Fmm2），纵向钢筋为HRB400（fy＝360N\u002Fmm2），箍筋采用HPB235（f＝210N\u002Fmm2）。屋面恒荷载标准值为4.8kN\u002Fm2，屋面活荷载标准值为0.5kN\u002Fm2，楼面恒荷载标准值为3.8kN\u002Fm2，活荷载标准值为2.0kN\u002Fm2，墙体自重标准值（包括双面粉刷）为2.61kN\u002Fm2，梁支座下设190mm×190mm上下贯通钢筋混凝土构造柱。托梁的截面尺寸bb×hb＝250mm×600mm（石灰水粉刷）。各层墙顶均设截面为190mm×190mm的钢筋混凝土圈梁。 5.确定使用阶段墙梁在其恒荷载设计值VbA（kN）和活荷载设计值最不利布置下托梁支座的剪力设计值VbB（kN）与下列（ ）组数值最接近。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","140.71；246.99",true,{"key":16,"text":17,"correct":18},"B","133.921；246.99",false,{"key":20,"text":21,"correct":18},"C","140.71；216.99",{"key":23,"text":24,"correct":18},"D","133.921；216.37","按连续梁分析A支座由托梁顶面荷载设计值产生的最不利剪力为：V1＝0.375×19.6×5.30＋0.437×9.24×5.30＝60.36kN； 墙梁顶面荷载设计值在支座A产生的最不利剪力为：V2＝0.375× 52.85×5.30＋0.437×12.47×5.30＝133.92kN； 考虑墙梁组合作用的支座A最不利剪力为：VbA=V1+βvV2=60.36＋0.6×133.92＝140.71kN； 按连续梁分析B支座在托梁顶面荷载作用下最不利剪力为：V1=0.625Q1l0=0.625×（19.60＋9.24）×5.30＝95.53kN； 墙梁顶面荷载作用下B支座最不利剪力为：V2=0.625Q2l0＝0.625×（52.85＋12.47）×5.30＝216.37kN； B支座的剪力设计值为：VbB=V1+βvV2＝95.53＋0.7×216.37＝246.99kN。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]