[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928224":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928224,599,1,"单选题","某砖拱端部墙体宽度为490mm，墙体厚度为370mm（见图），采用MU10烧结普通砖、M5混合砂浆砌筑。由永久荷载产生的窗间墙上部轴向压力设计值Nu=33kN，由永久荷载和可变荷载产生的砖拱水平推力V=18.2kN（由永久荷载效应组合控制设计），该墙体水平受剪承载力验算表达式接近下列（ ）项数值。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","18.20kN＜22.25kN",true,{"key":16,"text":17,"correct":18},"B","18.20kN＜23.04kN",false,{"key":20,"text":21,"correct":18},"C","18.20kN＜24.57kN",{"key":23,"text":24,"correct":18},"D","18.20kN＜25.07kN","MU10砖、M5混合砂浆，根据《砌体结构设计规范》（GB 50003—2011）第3.2.1条表3.2.1-1可知，砌体抗压强度为：f=1.5N\u002Fmm2； M5混合砂浆，根据第3.2.2条表3.2.2可知，砌体抗剪强度设计值为：fv=0.11N\u002Fmm2； 又A=0.49×0.37＝0.1813m2＜0.3m2，故砌体强度调整系数为：γa=0.7+A=0.7+0.1813=0.8813，则取f=0.8813×1.5=1.322N\u002Fmm2，fv=0.8813×0.11=0.097N\u002Fmm2； 平均压应力为：σ0=Nu\u002FA=33000\u002F181300=0.182N\u002Fmm2；则轴压比为：σ0\u002Ff=0.182\u002F1.322=0.138；又γG=1.35，则根据第5.5.1条式（5.5.1-3）计算，剪压复合受力影响系数为：μ＝0.23-0.065σ0\u002Ff=0.23-0.065×0.182\u002F1.322＝0.221； 取α=0.64，则受剪承载力为：V＝18.2kN＜（fv+αμσ0）A＝（0.097+0.64×0.221×0.182）×181300＝22.25KN。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]