[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-928172":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},928172,599,1,"单选题","某钢筋混凝土挑梁如图所示，l=1.5m，l1=2.8m，b=240mm，hb=300mm。挑出截面高度150mm，挑梁上墙体高度2.8m，墙厚h=240mm。墙端设有构造柱240mm×240mm，距墙边1.6m处开门洞，bh=900mm，hh=2100mm，楼板传给挑梁的荷载标准值为：梁端集中作用的恒载Fk=4.5kN，作用在挑梁挑出部分和埋入墙内部分的恒载g1k=17.75kN\u002Fm，g2k=10kN\u002Fm，作用在挑出部分的活载q1k=8.52kN\u002Fm，埋入墙内部分的活载q2k=4.95kN\u002Fm，挑梁挑出部分自重1.56kN\u002Fm，挑梁埋在墙内部分自重1.98kN\u002Fm，墙体自重19kN\u002Fm3。 2.楼层的抗倾覆最接近于（ ）kN·m。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","57.15",true,{"key":16,"text":17,"correct":18},"B","75.50",false,{"key":20,"text":21,"correct":18},"C","80.68",{"key":23,"text":24,"correct":18},"D","88.25","根据《砌体结构设计规范》（GB 50003—2011）第7.4.3条及图7.4.3可知，洞口右侧到梁端头的距离为300mm＜370mm，不考虑挑梁层端上部45°扩展角范围的墙重，只能考虑直接位于挑梁上部的墙体重量。 则墙体的抗倾覆力矩为：Mr1=0.8×0.24×19×[2.8×（2.8－0.3）×（1.4－0.045）－0.9×2.1×（1.6+0.9\u002F2－0.045）]=20.78kN·m； 楼板的抗倾覆力矩为：Mr2=0.8×（10+1.98）×（2.8－0.045）2\u002F2=36.37kN·m； 则楼层的抗倾覆力矩为：Mr=Mr1+Mr2=20.78+36.37=57.15kN·m。由此可知，A项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]