[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927996":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},927996,599,1,"单选题","某24层高层住宅楼，首层层高3.25m，结构总高度66.80m，采用钢筋混凝土全现浇剪力墙结构。底层某矩形剪力墙混凝土强度等级为C35，墙体端部约束边缘构件纵向受力钢筋采用HRB400级，墙体分布钢筋和端部约束边缘构件箍筋采用HRB335级。 3.题（2）中，若静载下此墙肢轴压力Nd＝2401.0kN，活载作用下此墙肢轴压力Nl＝379.5kN，则此墙肢的轴压比为（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","0.222",false,{"key":16,"text":17,"correct":14},"B","0.238",{"key":19,"text":20,"correct":21},"C","0.269",true,{"key":23,"text":24,"correct":14},"D","0.292","剪力墙肢轴压比的计算公式为：μ=N\u002FfcA，式中，N为墙肢的重力荷载代表值。 根据《建筑抗震设计规范》（GB 50011—2010）第5.1.3条规定，墙肢的重力荷载代表值可按下式组合得到：N=1.2Nd+1.4×0.5Nl=1.2×2401+1.4×0.5×379.5=3146.9kN。 则该墙肢的轴压比为：N\u002F（fcA）=3146.9×103\u002F（16.7×200×3500）=0.269。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]