[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927968":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},927968,599,1,"单选题","某多层现浇钢筋混凝土框架结构，其中间层高H＝2.8m，圆形装饰柱直径d＝300mm，混凝土强度等级为C30，纵向受力钢筋为HRB335，纵筋的混凝土保护层厚度c＝30mm，配置螺旋式间接钢筋，箍筋直径为8mm，箍筋间距s＝50mm，箍筋为HPB300钢筋。 1.假定柱的轴向压力设计值N＝1240kN，对柱进行轴心受压构件验算（不计入间接钢筋的影响），则柱的纵向受力钢筋的最小计算面积为（ ）mm2。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","1376",false,{"key":16,"text":17,"correct":14},"B","1439",{"key":19,"text":20,"correct":14},"C","1669",{"key":22,"text":23,"correct":24},"D","2039",true,"轴心受压构件验算（不考虑间接钢筋的影响）如下： 根据《混凝土结构设计规范》（GB 50010—2010）第6.2.20条表6.2.20-2可知，多层现浇框架房屋中间层柱的计算长度l0＝1.25H＝1.25×2.8＝3.5m，则l0\u002Fd=3500\u002F260=13.5。 根据第6.2.15条表6.2.15可知，钢筋混凝土轴心受压构件的稳定系数φ＝0.87； 圆形截面面积A＝π×d2\u002F4＝70686mm2； 轴压比Uc＝N\u002F（fcA）＝1240000\u002F（14.3×70686）＝1.22； 根据第6.2.15条式（6.2.15）计算，N≤0.9（fcA－f y′A s′），则全部纵向钢筋的截面面积应满足：",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]