[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927966":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},927966,599,1,"单选题","一无吊车工业厂房，采用刚性屋盖，跨度为15m，其铰接排架结构计算简图及所承受的荷载设计值如图所示。柱的截面尺寸为400mm×400mm，as＝40mm，混凝土强度等级为C30，结构安全等级为二级，纵向受力钢筋为HRB335。 2.假定柱子的净高Hn＝5m，柱底截面内力设计值为M＝100kN·m，N＝450kN，V＝30kN，则轴向压力作用点至纵向受拉钢筋的合力点的距离e最接近于（ ）mm。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","360",false,{"key":16,"text":17,"correct":18},"B","420",true,{"key":20,"text":21,"correct":14},"C","477",{"key":23,"text":24,"correct":14},"D","489","根据《混凝土结构设计规范》（GB 50010—2010）第4.1.4条表4.1.4-2可知，C30混凝土，轴心抗压强度设计值fc＝14.33N\u002Fmm2；根据第4.2.3条表4.2.3-1和第4.2.5条表4.2.5可知，钢筋抗拉强度设计值fy＝300N\u002Fmm2，抗压强度设计值＝300N\u002Fmm2，弹性模量Es＝200000N\u002Fmm2，相对界限受压区高度ξb＝0.550，纵筋的混凝土保护层厚度c＝30mm，全部纵筋最小配筋率为：ρmin＝0.60%；附加偏心距为：ea＝max{20，h\u002F30}＝max{20，13}＝20mm；轴向压力对截面重心的偏心距为：e0＝M\u002FN＝100000000\u002F450000＝222mm；初始偏心距为：ei＝e0＋ea＝222＋20＝242mm； 根据第6.2.17条式（6.2.17-3）计算，则轴向压力作用点至纵向受拉钢筋的合力点的距离为： 由此可知，B项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]