[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927934":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},927934,599,1,"单选题","已知某公共建筑底层门厅内现浇钢筋混凝土圆柱，承受轴心压力设计值N＝5200kN，该柱的截面尺寸d＝550mm，柱的计算长度l0＝5.2m，混凝土强度等级为C30（fc＝14.3N\u002Fmm2），柱中纵筋用HRB335级（fy′＝300N\u002Fmm2），箍筋用HPB300级（fyv＝270N\u002Fmm2）。 3.若已知s＝40mm，则柱的轴向力设计值Nu为（ ）kN。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","4348",false,{"key":16,"text":17,"correct":14},"B","4653",{"key":19,"text":20,"correct":14},"C","5334",{"key":22,"text":23,"correct":24},"D","6296",true,"根据《混凝土结构设计规范》（GB 50010—2010）第6.2.16条式（6.2.16-2）计算，螺旋箍筋间距为： 则间接钢筋的换算截面面积为：Ass0=3.14×500×78.5\u002F40=3081.1mm2； 根据第6.2.16条式（6.2.16-1）计算，螺旋式间接钢筋柱的承载力为： 根据第6.2.15条式（6.2.15）计算，普通钢筋柱的承载力为： 满足规范要求。 故柱的轴向力设计值为6296kN。由此可知，D项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]