[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927933":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},927933,599,1,"单选题","已知某公共建筑底层门厅内现浇钢筋混凝土圆柱，承受轴心压力设计值N＝5200kN，该柱的截面尺寸d＝550mm，柱的计算长度l0＝5.2m，混凝土强度等级为C30（fc＝14.3N\u002Fmm2），柱中纵筋用HRB335级（fy′＝300N\u002Fmm2），箍筋用HPB300级（fyv＝270N\u002Fmm2）。 2.若采用螺旋箍筋，纵筋选用16Φ22HRB335级钢筋，混凝土的保护层厚度取用25mm，螺旋箍筋直径d＝10mm。螺旋筋的间距s最接近于（ ）mm。（单肢螺旋筋面积Ass1=78.5mm2）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","45",false,{"key":16,"text":17,"correct":14},"B","50",{"key":19,"text":20,"correct":21},"C","58",true,{"key":23,"text":24,"correct":14},"D","60","构件的核心直径为： 构件的核心截面面积为： 根据《混凝土结构设计规范》（GB 50010—2010）第6.2.16条式（6.2.16-1）计算，正截面受压承载力应满足： 则间接钢筋的换算截面面积为： 满足构造要求。 根据第6.2.16条式（6.2.16-2）计算，已知单肢螺旋筋面积Assl=78.5mm2，故螺旋筋的间距为： 由此可知，C项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]