[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927923":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},927923,599,1,"单选题","圆形截面轴心受压柱，直径d＝500mm，计算长度l0＝5200mm。受轴心压力设计值N＝4500kN，混凝土强度等级为C30，纵筋用HRB335级钢筋，箍筋用HPB300级钢筋。 1.按配有普通纵筋和箍筋柱计算，所需纵向受压钢筋面积As′最接近（ ）mm2。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","7798.19",false,{"key":16,"text":17,"correct":14},"B","7981.36",{"key":19,"text":20,"correct":14},"C","8184.51",{"key":22,"text":23,"correct":24},"D","8594.17",true,"由l0\u002Fd＝5200\u002F500＝10.4，根据《混凝土结构设计规范》（GB 50010—2010）第6.2.15条表6.2.15可知，钢筋混凝土轴心受压构件的稳定系数；柱截面面积A＝πd2\u002F4＝π×5002\u002F4＝19.635×104mm2，则计算得纵向钢筋截面面积为： 配筋率为：ρ′=As′\u002FA=（8184.51\u002F19.635×104）×100%=4.17%>3%； 根据第6.2.15条规定，当纵向钢筋配筋率大于3%时，A应改用（A-A s′）代替，即： 配筋率为：ρ′=（8594.16\u002F19.635×104）×100%=4.38%\u003C5%，满足规范要求。由此可知，D项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]