[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927918":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},927918,599,1,"单选题","某钢筋混凝土柱，截面尺寸为300mm×500mm，混凝土强度等级为C30，纵向受力钢筋为HRB400，纵向钢筋合力点至截面近边缘的距离as＝a s′＝40mm。 1.设柱的计算长度为3m，承受的轴心压力设计值N＝1100kN，弯矩设计值M＝250kN·m，则轴向压力作用点至纵向受拉钢筋的合力点的距离e（mm）最接近于（ ）项数值。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","380",false,{"key":16,"text":17,"correct":18},"B","452",true,{"key":20,"text":21,"correct":14},"C","469",{"key":23,"text":24,"correct":14},"D","484","根据《混凝土结构设计规范》（GB 50010—2010）计算过程如下： ①根据第6.2.5条规定，附加偏心距 而轴向压力对截面重心的偏心距e0＝M\u002FN＝250000000\u002F1100000＝227mm，则初始偏心距为：ei＝e0＋ea＝227＋20＝247mm； ②根据第6.2.4条式（6.2.4-4）计算，偏心受压构件的截面曲率修正系数为： ζ1=0.5fcA\u002FN=0.5×14.33×150000\u002F1100000=0.98； ③根据附录G第G.0.2条规定，截面有效高度h0=h-as=500-40=460mm； ④根据第6.2.17条式（6.2.17-3）计算，轴向压力作用点至纵向受拉钢筋的合力点的距离为： 由此可知，B项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]