[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-927917":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},927917,599,1,"单选题","非预应力钢筋混凝土屋架如图2-36所示。已知集中荷载P＝GK＋QK，静载GK＝10.5kN（包括构件自重），活载QK＝9.6kN。提示：活载标准值大于4.0kN\u002Fm2，计算屋架杆件内力时不考虑节点次应力的影响。 4.若下弦杆截面尺寸均为b×h＝250mm×250mm，采用C35级混凝土，纵向受力钢筋采用HRB335级。设下弦杆S4轴向力标准值Nk＝181.6kN，全截面纵向受力钢筋为Φ14，混凝土保护层c＝30mm，则杆件的最大裂缝宽度最接近于（ ）mm。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","0.131",false,{"key":16,"text":17,"correct":18},"B","0.138",true,{"key":20,"text":21,"correct":14},"C","0.142",{"key":23,"text":24,"correct":14},"D","0.149","由题意可知，deq=d=14mm，As=1231.5mm2，A=62500mm2，ρte=1231.5\u002F62500=0.0197；ftk=2.2N\u002Fmm2，Es=2×105N\u002Fmm2，c=30mm，as=38mm，Nk=181.6×103N，且σsk=Nk\u002FAs=147.46N\u002Fmm2； 根据《混凝土结构设计规范》（GB 50010—2010）第7.1.2条式（7.1.2-2）计算，裂缝间纵向受拉钢筋应变不均匀系数为：ψ=1.1-0.65ftk\u002Fρte\u002Fσsk=0.608； 由于下弦杆为轴心受拉，根据第7.1.2条表7.1.2-1可知，构件受力特征系数αcr＝2.7。 根据第7.1.2条式（7.1.2-1）计算，最大裂缝宽度为： 由此可知，B项数值最为接近。",{"id":6,"name":27,"category":28,"favorite":29},"(结构) 专业考试二级","建筑工程",0]